Accuracy of freehand surgery, static and dynamic computer assisted surgery on zygomatic implant placement: A systematic review and meta-analyses

被引:1
|
作者
Traboulsi-Garet, Bassel [1 ]
Jorba-Garcia, Adria [1 ,4 ]
Bara-Casaus, Javier [1 ,2 ,3 ]
Camps-Font, Octavi [1 ,4 ]
Valmaseda-Castellon, Eduard [1 ,4 ]
Figueiredo, Rui [1 ,4 ]
Sanchez-Garces, Angels [1 ,4 ]
机构
[1] Univ Barcelona, Sch Med & Hlth Sci, Barcelona, Spain
[2] Hosp Univ Sagrat Cor, Grp Quironsalud, Dent & Maxillofacial Inst, Barcelona, Spain
[3] Univ Barcelona, Hosp Univ Mutua Terrassa, Dept Oral & Maxillofacial Surg, Terrassa, Spain
[4] IDIBELL Inst, Barcelona, Spain
关键词
Accuracy; Zygomatic implants; Arch; /; Zygomatic; Image guided surgery; Static guided surgery; TIME SURGICAL NAVIGATION; DENTAL IMPLANTS; GUIDED SURGERY; PATIENT; REHABILITATION; COMPLICATIONS; SURVIVAL;
D O I
10.1016/j.jcms.2024.12.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Real-time surgical navigation systems (dynamic computer-aided surgery, d-CAIS) and static guided surgery (static computer-aided surgery, s-CAIS) have been shown to enhance the accuracy of zygomatic implant (ZI) placement. The objective of this systematic review was to evaluate and compare the accuracy and risk of complications associated with d-CAIS and s-CAIS in ZI placement. A systematic review of published studies involving more than 4 patients was conducted to assess and compare the accuracy of d-CAIS and s-CAIS in zygomatic implant placement. Only one study included freehand ZI placement as a control. The primary outcomes measured were the accuracy of implant placement relative to preoperative planning, with a secondary focus on evaluating any potential complications. Out of 903 screened studies, 14 met the inclusion criteria. Freehand zygomatic implant placement was used as a control in only 1 study. The results revealed a mean apex deviation of 2.07 mm (95% CI: 2.01 to 2.13; I2 = 83.14%) for d-CAIS, 1.29 mm (95% CI: 1.15 to 1.43; I2 = 94.5%) for s-CAIS, and 4.98 mm (95% CI: 3.59 to 6.37; I2 = not assessable) for freehand placement. Reported complications included mucositis, reversible bilateral sinusitis, oroantral fistula, unspecified reversible postoperative complications, and fracture of the anterior wall of the zygoma. Both CAIS systems demonstrated high accuracy and safety in ZI placement, with a nearly 99% success rate at 6 months of follow-up. These findings suggest that both d-CAIS and s-CAIS are reliable methods for improving the precision and reducing the risks associated with ZI procedures.
引用
收藏
页码:301 / 311
页数:11
相关论文
共 50 条
  • [31] Computer-Guided Surgery for Dental Implant Placement: A Systematic Review
    Araujo-Corchado, Elena
    Pardal-Pelaez, Beatriz
    PROSTHESIS, 2022, 4 (04): : 540 - 553
  • [32] Accuracy assessment of dynamic computer-aided implant placement: a systematic review and meta-analysis
    Jorba-Garcia, Adria
    Gonzalez-Barnadas, Albert
    Camps-Font, Octavi
    Figueiredo, Rui
    Valmaseda-Castellon, Eduard
    CLINICAL ORAL INVESTIGATIONS, 2021, 25 (05) : 2479 - 2494
  • [33] Does implant drill design influence the accuracy of dental implant placement using static computer-assisted implant surgery? An in vitro study
    Takacs, Anna
    Marada, Gyula
    Turzo, Kinga
    Nagy, Akos
    Nemeth, Orsolya
    Mijiritsky, Eitan
    Kivovics, Marton
    Muhl, Attila
    BMC ORAL HEALTH, 2023, 23 (01)
  • [34] Does implant drill design influence the accuracy of dental implant placement using static computer-assisted implant surgery? An in vitro study
    Anna Takács
    Gyula Marada
    Kinga Turzó
    Ákos Nagy
    Orsolya Németh
    Eitan Mijiritsky
    Márton Kivovics
    Attila Mühl
    BMC Oral Health, 23
  • [35] Psychologic Status and Influence of Surgery Techniques on Acute Nonneuropathic Pain After Dental Implant Surgery: Systematic Review and Meta-analyses
    Lopez-Lopez, Jose
    Ramezanzade, Shaqayeq
    Atabaki, Mehdi
    Sadeghi, Erfan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (02) : 248 - 269
  • [36] The Value of Systematic Reviews and Meta-Analyses in Surgery
    Knight, Simon R.
    EUROPEAN SURGICAL RESEARCH, 2021, 62 (04) : 221 - 228
  • [38] Incidence of sinusitis after surgery for zygomatic implant placement in patients with atrophic maxilla: A systematic review
    Miyasawa, Erton Massamitsu
    Vianna, Camila Pereira
    Rocha, Roberta Schroder
    Ribeiro Junior, Paulo Domingos
    Trojan, Larissa Carvalho
    Padovan, Luis Eduardo Marques
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY MEDICINE AND PATHOLOGY, 2023, 35 (02) : 103 - 108
  • [39] Freehand Versus Guided Surgery: Factors Influencing Accuracy of Dental Implant Placement
    Choi, William
    Nguyen, Bao-Chau
    Doan, Andrew
    Girod, Sabine
    Gaudilliere, Brice
    Gaudilliere, Dyani
    IMPLANT DENTISTRY, 2017, 26 (04) : 500 - 509
  • [40] Accuracy of implant placement via dynamic navigation and autonomous robotic computer-assisted implant surgery methods: A retrospective study
    Zhang, Sihui
    Cai, Qin
    Chen, Weiyi
    Lin, Yuxuan
    Gao, Yan
    Wu, Dong
    Chen, Jiang
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (02) : 220 - 229