Comparison of noninvasive electrical cardiometry and transpulmonary thermodilution for cardiac output measurement in critically ill patients: a prospective observational study

被引:0
|
作者
Song, Wenliang [1 ,4 ]
Guo, Jiayan [2 ]
Cao, Daiyin [3 ]
Jiang, Jinlong [1 ,4 ]
Yang, Tao [1 ,4 ]
Ma, Xiaoxun [1 ,4 ]
Yuan, Hao [1 ,4 ]
Wu, Jianfeng [1 ,4 ]
Guan, Xiangdong [1 ,4 ]
Si, Xiang [1 ,4 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Crit Care Med, Guangzhou 510080, Peoples R China
[2] Guangzhou Women & Childrens Med Ctr, Dept Anesthesiol, Guangzhou 510623, Guangdong, Peoples R China
[3] Sun Yat Sen Univ, Affiliated Hosp 6, Dept Crit Care Med, Guangzhou 510655, Peoples R China
[4] Guangdong Clin Res Ctr Crit Care Med, Guangzhou 510080, Peoples R China
来源
BMC ANESTHESIOLOGY | 2025年 / 25卷 / 01期
关键词
Noninvasive; Thoracic fluid content; Extravascular lung water; Metrology; stroke volume; Haemodynamic; PULSE-CONTOUR ANALYSIS; PULMONARY-ARTERY THERMODILUTION; STROKE VOLUME EQUATION; LUNG FLUID; VELOCIMETRY; BIOIMPEDANCE; AGREEMENT; ACCURACY; TIME;
D O I
10.1186/s12871-025-03005-1
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Cardiac output (CO) monitoring is essential for diagnosing and managing critically ill patients. Recently, a non-invasive haemodynamic monitoring technique, electrical cardiometry (EC), has gathered increasing interest among ICU physicians. This study aimed to explore the accuracy of CO estimated by non-invasive EC (COEC) compared to CO determined by transpulmonary thermodilution (COTPTD) and to evaluate the ability of COEC to track COTPTD changes (Delta COTPTD). Methods: This prospective, observational, single-center study was conducted from April 2021 to April 2023, involving patients who required haemodynamic monitoring using a transpulmonary thermodilution device (PiCCO). COTPTD and COEC were recorded simultaneously, with the investigators obtaining the COEC measurements were blinded to the COTPTD results and vice versa. Agreement between the methods was evaluated using Bland-Altman analysis and percentage error (PE). The ability of COEC to track changes in COTPTD was examined using four-quadrant and polar plots. Results: Seventy-two patients with PiCCO haemodynamic monitoring were included, yielding 285 paired CO measurements. The bias between COEC and COTPTD was 0.47 L/min, with a limit of agreement (LoA) ranging from -2.91 to 3.85 L/min and a PE of 54.0%. Among 212 pairs of Delta CO data, excluding a central zone of 15% in the four-quadrant plot, the concordance rate between Delta COEC % and Delta COTPTD % was 70%. In the polar plot, excluding a central zone with a radius of 0.625 L/min (10% of the mean COTPTD), the mean polar angle for Delta COEC was 2.2 degrees, with a radial LoA of 56.0 degrees. Exploratory subgroup analysis indicated a PE of 47.0% between COEC and COTPTD and a concordance rate of 72% between Delta COEC% and Delta COTPTD% in patients with normal CO (CO >= 4 L/min). In patients with elevated thoracic fluid content (TFC > 35 k Omega), the PE between COEC and COTPTD was 45.0%, with a concordance rate of 64% between Delta COEC% and Delta COTPTD%. Additionally, in patients receiving low-dose norepinephrine equivalents (NEE <= 0.25 mu g/kg/min), COEC and COTPTD exhibited a PE of 45.0%, while Delta COEC% and Delta COTPTD% achieved a concordance rate of 75% and a radial LoA of 44.2 degrees. Conclusion: In critically ill patients, non-invasive EC indicated limited accuracy in measuring CO, along with a restricted ability to reliably track CO changes. These findings suggested that EC may not be interchangeable with TPTD in the general ICU population.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Influence of prone positioning on the measurement of transpulmonary thermodilution-derived variables in critically ill patients
    Bruecken, U.
    Grensemann, J.
    Wappler, F.
    Sakka, S. G.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (09) : 1061 - 1067
  • [42] Comparison of electrical velocimetry and thermodilution techniques for the measurement of cardiac output
    Zoremba, N.
    Bickenbach, J.
    Krauss, B.
    Rossaint, R.
    Kuhlen, R.
    Schaelte, G.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2007, 51 (10) : 1314 - 1319
  • [43] Noninvasive Cardiac Output Assessment In Critically Ill Pediatric Patients
    Wongsirimetheekul, T.
    Khositseth, A.
    Lertbunrian, R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [44] Noninvasive monitoring of cardiac output in critically ill patients with thoracocardiography
    Bloch, KE
    Baumann, PC
    Stocker, R
    Russi, EW
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 155 (01) : 26 - 31
  • [45] Effects of cardiac output levels on the measurement of transpulmonary thermodilution cardiac output in patients with acute respiratory distress syndrome
    Huang, Chung-Chi
    Chen, Ning-Hung
    Li, Li-Fu
    Yang, Cheng-Ta
    Hsiao, Hsiu-Feng
    Chen, Yen-Huey
    Lin, Hui-Ling
    Kao, Kuo-Chin
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2012, 73 (05): : 1236 - 1241
  • [46] IS CONTINUOUS CARDIAC-OUTPUT MEASUREMENT USING THERMODILUTION RELIABLE IN THE CRITICALLY ILL PATIENT
    BOLDT, J
    MENGES, T
    WOLLBRUCK, M
    HAMMERMANN, H
    HEMPELMANN, G
    CRITICAL CARE MEDICINE, 1994, 22 (12) : 1913 - 1918
  • [47] CARDIAC OUTPUT MEASUREMENTS WITH AN UNCALIBRATED PULSE CONTOUR METHOD IN CRITICALLY ILL PATIENTS: COMPARISON WITH THERMODILUTION AND ECHOCARDIOGRAPHY
    Scolletta, Sabino
    Bodson, Laurent
    Donadello, Katia
    Devigili, Alessandro
    Taccone, Fabio Silvio
    Herpain, Antoine
    Vincent, Jean-Louis
    De Backer, Daniel
    CRITICAL CARE MEDICINE, 2010, 38 (12) : U64 - U64
  • [48] Reproducibility of thermodilution cardiac output determination in critically ill patients: Comparison between bolus and continuous method
    LeTulzo, Y
    Belghith, M
    Seguin, P
    DallAva, J
    Monchi, M
    Thomas, R
    Dhainaut, JF
    JOURNAL OF CLINICAL MONITORING, 1996, 12 (05): : 379 - 385
  • [49] THERMODILUTION CARDIAC-OUTPUT IN CRITICALLY ILL PATIENTS - COMPARISON OF ROOM-TEMPERATURE AND ICED INJECTATE
    VENNIX, CV
    NELSON, DH
    PIERPONT, GL
    HEART & LUNG, 1984, 13 (05): : 574 - 578
  • [50] Lack of agreement between thermodilution and fick cardiac output in critically ill patients
    Dhingra, VK
    Fenwick, JC
    Walley, KR
    Chittock, DR
    Ronco, JJ
    CHEST, 2002, 122 (03) : 990 - 997