Improving image reconstruction to quantify dynamic whole-body PET/CT: Q.Clear versus OSEM

被引:0
|
作者
Springer, Sam [1 ]
Basset-Sagarminaga, Jeremy [2 ,4 ]
van de Weijer, Tineke [1 ,2 ,4 ]
Schrauwen-Hinderling, Vera B. [1 ,4 ]
Backes, Walter H. [1 ,3 ]
Wierts, Roel [1 ]
机构
[1] Maastricht Univ Med Ctr, Dept Radiol & Nucl Med, Maastricht, Netherlands
[2] Maastricht Univ, Dept Nutr & Movement Sci, Maastricht, Netherlands
[3] Maastricht Univ, Res Inst Mental Hlth & Neurosci & Cardiovasc Dis, Maastricht, Netherlands
[4] Maastricht Univ, Inst Nutr & Translat Res Metab, Maastricht, Netherlands
来源
EJNMMI PHYSICS | 2025年 / 12卷 / 01期
关键词
PET/CT; F-18-FDG; Reconstruction; Bayesian; Dynamic; Whole-body;
D O I
10.1186/s40658-025-00736-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The introduction of PET systems featuring increased count rate sensitivity has resulted in the development of dynamic whole-body PET acquisition protocols to assess F-18-FDG uptake rate (Ki) using F-18-FDG PET/CT. However, in short-axis field-of-view (SAFOV) PET/CT systems, multiple bed positions are required per time frame to achieve whole-body coverage. This results in high noise levels, requiring higher F-18-FDG activity administration and, consequently, increased patient radiation dose. Bayesian penalized-likelihood PET reconstruction (e.g. Q.Clear, GE Healthcare) has been shown to effectively suppress image noise compared to standard reconstruction techniques. This study investigated the impact of Bayesian penalized-likelihood reconstruction on dynamic whole-body F-18-FDG PET quantification. Methods: Dynamic whole-body F-18-FDG PET/CT data (SAFOV PET Discovery MI 5R, GE Healthcare) of healthy volunteers and one lung cancer patient, consisting of a ten-minute dynamic scan of the thoracic region followed by six whole-body passes, were reconstructed with Q.Clear and Ordered Subset Expectation Maximization (OSEM) according to EARL 2 standards. Image noise in the measured time-activity-curves (TAC) was determined for the myocardium, hamstring, liver, subcutaneous adipose tissue and lung lesion for both reconstruction methods. Ki values were calculated using Patlak analysis. Finally, bootstrapping was used to investigate the effect of image noise levels on Ki values (bias and precision) as a function of magnitude of Ki and volume-of-interest (VOI) size for both computationally simulated TACs (Ki = 1.0-50.0<middle dot>10(-3)<middle dot>ml<middle dot>cm(-3)<middle dot>min(-1)) and the measured TACs. Results: Compared to OSEM, Q.Clear showed 40-55% lower noise levels for all tissue types (p < 0.05). For the measured TACs no systematic bias in Ki with either reconstruction method was observed. Ki precision decreased with decreasing VOI size, with that of Q.Clear being superior compared to OSEM for small VOIs of 0.56 cm(3) in all tissues (p < 0.05), with the largest difference in relative precision for small values of Ki. The simulated TACs corroborated these results, with Q.Clear providing the best precision for small values of Ki and small VOIs in all tissues. Conclusion: Q.Clear reconstruction of dynamic whole-body PET/CT data yields more precise Ki values, especially for small values of Ki and smaller VOIs, compared to standard OSEM. This precision improvement shows Q.Clear's potential to better detect and characterize small lesion metabolic activity in oncology and allows for lower administered activity dosage.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Strategies to improve 3D whole-body PET image reconstruction
    Cutler, PD
    Xu, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (08): : 1453 - 1467
  • [32] Effect of MR truncation compensation on quantitative PET image reconstruction for whole-body PET/MR
    Tang, Jing
    Haagen, Rainald
    Blaffert, Thomas
    Renisch, Steffen
    Blaeser, Andreas
    Salomon, Andre
    Schweizer, Bernd
    Hu, Zhiqiang
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2506 - 2509
  • [33] Application of a generic dynamic reconstruction algorithm on PET whole-body pharmacokinetic studies
    Chalampalakis, Z.
    Stute, S.
    Filipovic, M.
    Marie, S.
    Bottlaender, M.
    Tournier, N.
    Comtat, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S416 - S416
  • [34] Bayesian Penalized Likelihood Image Reconstruction (Q.Clear) in 82Rb Cardiac PET: Impact of Count Statistics
    Christensen, N.
    Tolbod, L. P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S342 - S342
  • [35] Q.Clear reconstruction optimization for digital PET: finding optimal balance between patient comfort, received dose and image quality
    Krizsan, A. K.
    Acs, A.
    Forgacs, A.
    Klagyvik, D.
    Garai, I.
    Szabo, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S693 - S694
  • [36] Comparison of Whole-Body Versus Limited Whole-Body 18F-FDG PET/CT Scan in Malignant Cutaneous Melanoma
    Lazaga, Francisco Jose
    Oez, Orhan K.
    Adams-Huet, Beverley
    Anderson, Jon
    Mathews, Dana
    CLINICAL NUCLEAR MEDICINE, 2013, 38 (11) : 882 - 884
  • [37] Impact of elastic motion correction on quantitation and image quality of whole-body PET/CT
    Meier, Joseph
    Hamill, James
    Jones, Judson
    Hong, Inki
    Mawlawi, Osama
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [38] Whole-Body Nonenhanced PET/MR versus PET/CT in the Staging and Restaging of Cancers: Preliminary Observations
    Huellner, Martin W.
    Appenzeller, Philippe
    Kuhn, Felix P.
    Husmann, Lars
    Pietsch, Carsten M.
    Burger, Irene A.
    Porto, Miguel
    Delso, Gaspar
    von Schulthess, Gustav K.
    Veit-Haibach, Patrick
    RADIOLOGY, 2014, 273 (03) : 859 - 869
  • [39] Optimisation of penalized likelihood estimation reconstruction (Q.Clear) on a digital time-of-flight PET-CT scanner for four different PET tracers
    Lindstrom, Elin
    Lindsjo, Lars
    Ilan, Ezgi
    Sundin, Anders
    Sorensen, Jens
    Danfors, Torsten
    Antoni, Gunnar
    Lubberink, Mark
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [40] Impact of Radiation Dose Reduction of CT component in Whole-Body PET/CT Protocols on CT Image quality
    Ali, I.
    Mohamed, Y.
    Naser, I.
    Amin, M. I.
    Gawad, H. Abdel
    Hamdy, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S781 - S782