Improving image reconstruction to quantify dynamic whole-body PET/CT: Q.Clear versus OSEM

被引:0
|
作者
Springer, Sam [1 ]
Basset-Sagarminaga, Jeremy [2 ,4 ]
van de Weijer, Tineke [1 ,2 ,4 ]
Schrauwen-Hinderling, Vera B. [1 ,4 ]
Backes, Walter H. [1 ,3 ]
Wierts, Roel [1 ]
机构
[1] Maastricht Univ Med Ctr, Dept Radiol & Nucl Med, Maastricht, Netherlands
[2] Maastricht Univ, Dept Nutr & Movement Sci, Maastricht, Netherlands
[3] Maastricht Univ, Res Inst Mental Hlth & Neurosci & Cardiovasc Dis, Maastricht, Netherlands
[4] Maastricht Univ, Inst Nutr & Translat Res Metab, Maastricht, Netherlands
来源
EJNMMI PHYSICS | 2025年 / 12卷 / 01期
关键词
PET/CT; F-18-FDG; Reconstruction; Bayesian; Dynamic; Whole-body;
D O I
10.1186/s40658-025-00736-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The introduction of PET systems featuring increased count rate sensitivity has resulted in the development of dynamic whole-body PET acquisition protocols to assess F-18-FDG uptake rate (Ki) using F-18-FDG PET/CT. However, in short-axis field-of-view (SAFOV) PET/CT systems, multiple bed positions are required per time frame to achieve whole-body coverage. This results in high noise levels, requiring higher F-18-FDG activity administration and, consequently, increased patient radiation dose. Bayesian penalized-likelihood PET reconstruction (e.g. Q.Clear, GE Healthcare) has been shown to effectively suppress image noise compared to standard reconstruction techniques. This study investigated the impact of Bayesian penalized-likelihood reconstruction on dynamic whole-body F-18-FDG PET quantification. Methods: Dynamic whole-body F-18-FDG PET/CT data (SAFOV PET Discovery MI 5R, GE Healthcare) of healthy volunteers and one lung cancer patient, consisting of a ten-minute dynamic scan of the thoracic region followed by six whole-body passes, were reconstructed with Q.Clear and Ordered Subset Expectation Maximization (OSEM) according to EARL 2 standards. Image noise in the measured time-activity-curves (TAC) was determined for the myocardium, hamstring, liver, subcutaneous adipose tissue and lung lesion for both reconstruction methods. Ki values were calculated using Patlak analysis. Finally, bootstrapping was used to investigate the effect of image noise levels on Ki values (bias and precision) as a function of magnitude of Ki and volume-of-interest (VOI) size for both computationally simulated TACs (Ki = 1.0-50.0<middle dot>10(-3)<middle dot>ml<middle dot>cm(-3)<middle dot>min(-1)) and the measured TACs. Results: Compared to OSEM, Q.Clear showed 40-55% lower noise levels for all tissue types (p < 0.05). For the measured TACs no systematic bias in Ki with either reconstruction method was observed. Ki precision decreased with decreasing VOI size, with that of Q.Clear being superior compared to OSEM for small VOIs of 0.56 cm(3) in all tissues (p < 0.05), with the largest difference in relative precision for small values of Ki. The simulated TACs corroborated these results, with Q.Clear providing the best precision for small values of Ki and small VOIs in all tissues. Conclusion: Q.Clear reconstruction of dynamic whole-body PET/CT data yields more precise Ki values, especially for small values of Ki and smaller VOIs, compared to standard OSEM. This precision improvement shows Q.Clear's potential to better detect and characterize small lesion metabolic activity in oncology and allows for lower administered activity dosage.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] Improving image quantification in dynamic whole-body PET-CT: BSREM vs. OSEM
    Springer, S.
    Basset-Sagarminaga, J.
    de Weijer, T. van
    Schrauwen-Hinderling, V. B.
    Backes, W. H.
    Wierts, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S749 - S749
  • [2] Comparison of Q.Clear and OSEM reconstruction algorithm on PET/CT images in patients with metastatic breast cancer
    Naghavi-Behzad, M.
    Vogsen, M.
    Gerke, O.
    Dahlsgaard-Wallenius, S. E.
    Nissen, H. J.
    Jakobsen, N. M.
    Braad, P.
    Vilstrup, M. H.
    Deak, P.
    Hildebrandt, M. G.
    Andersen, T. L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S306 - S307
  • [3] Standard OSEM vs. Q.Clear® PET image reconstruction: an analysis of phantom data.
    Lantos, Judit
    Iagaru, Andrei
    Levin, Craig
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [4] Comparison of Image Quality and Quantification Parameters between Q.Clear and OSEM Reconstruction Methods in FDG-PET/CT Imaging
    Sezgin, C.
    Goksoy, D.
    Gumuser, G.
    Sayit, E.
    Parlak, Y.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S943 - S944
  • [5] Does Bayesian penalized likelihood reconstruction (Q.Clear) for FDG-PET always outperform image quality of OSEM-based reconstruction?
    Rogasch, J. M. M.
    Hofheinz, F.
    Suleiman, S.
    Lukas, M.
    Amthauer, H.
    Furth, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S781 - S781
  • [6] Comparison of Image Quality and Quantification Parameters between Q.Clear and OSEM Reconstruction Methods on FDG-PET/CT Images in Patients with Metastatic Breast Cancer
    Naghavi-Behzad, Mohammad
    Vogsen, Marianne
    Gerke, Oke
    Dahlsgaard-Wallenius, Sara Elisabeth
    Nissen, Henriette Juel
    Jakobsen, Nick Moldrup
    Braad, Poul-Erik
    Vilstrup, Mie Holm
    Deak, Paul
    Hildebrandt, Malene Grubbe
    Andersen, Thomas Lund
    JOURNAL OF IMAGING, 2023, 9 (03)
  • [7] Scanner Dependent Noise Properties of the Q.Clear PET Image Reconstruction Tool
    Lantos, Judit
    Iagaru, Andrei
    Levin, Craig S.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [8] Optimization of Q.Clear reconstruction for dynamic 18F PET imaging
    Lysvik, Elisabeth Kirkeby
    Mikalsen, Lars Tore Gyland
    Rootwelt-Revheim, Mona-Elisabeth
    Emblem, Kyrre Eeg
    Hjornevik, Trine
    EJNMMI PHYSICS, 2023, 10 (01)
  • [9] Optimization of Q.Clear reconstruction for dynamic 18F PET imaging
    Elisabeth Kirkeby Lysvik
    Lars Tore Gyland Mikalsen
    Mona-Elisabeth Rootwelt-Revheim
    Kyrre Eeg Emblem
    Trine Hjørnevik
    EJNMMI Physics, 10
  • [10] ß-1600 Q.Clear Reconstruction Improves [68Ga]GaDOTANOC Digital PET/CT Image Quality
    Fortunati, E.
    Bonazzi, N.
    Di Franco, M.
    Zanoni, L.
    Mosconi, C.
    Civollani, S.
    Campana, D.
    Malizia, C.
    Allegri, V.
    Fanti, S.
    Ambrosini, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S515 - S515