Combined influence of quantum iterative reconstruction level and kernel sharpness on image quality in photon counting CT angiography of the upper leg

被引:0
|
作者
Krompass, Kristina [1 ]
Goldbrunner, Florian Andreas [1 ]
Hartung, Viktor [1 ]
Erguen, Sueleyman [2 ]
Peter, Dominik [3 ]
Hendel, Robin [1 ]
Huflage, Henner [1 ]
Patzer, Theresa Sophie [1 ]
Hennes, Jan-Lucca [1 ]
Bley, Thorsten Alexander [1 ]
Grunz, Jan-Peter [1 ,4 ]
Gruschwitz, Philipp [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Univ Wurzburg, Inst Anat & Cell Biol, Wurzburg, Germany
[3] Univ Hosp Wurzburg, Dept Gen Visceral Transplant Vasc & Pediat Surg, Wurzburg, Germany
[4] Univ Wisconsin Madison, Dept Radiol, Madison, WI 53792 USA
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
关键词
ARTERIAL OCCLUSIVE DISEASE; COMPUTED-TOMOGRAPHY; PERFORMANCE; MANAGEMENT;
D O I
10.1038/s41598-024-79188-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Aim was to evaluate the influence of different quantum iterative reconstruction (QIR) levels on the image quality of femoral photon-counting CT angiographies (PCD-CTA). Ultra-high resolution PCD-CTA were obtained from both extremities of five extracorporeally-perfused cadavers using constant tube voltage and maximum radiation dose (71.2 +/- 11.0 mGy). Images were reconstructed with three kernels (Bv48, Bv60, Bv76) and the four available levels of QIR. Signal attenuation in the arterial lumen, muscle, and fat were measured. Contrast-to-noise ratios (CNR) and blurring scores were calculated for objective assessment. Six radiologists evaluated the subjective image quality using a pairwise comparison tool. Higher QIR level resulted in a decisive image noise reduction, especially with sharper convolution kernels (Bv60: Q1 11.5 +/- 6.3 HU vs. Q4 8.4 +/- 2.6 HU; p < 0.001). Largest improvement of CNR was recorded with ultra-sharp reconstructions (Bv76: Q1 20.2 +/- 4.4 vs. Q4 28.0 +/- 3.5; p < 0.001). Blurring decreased with higher QIR levels for soft Bv48, remained constant for medium Bv60, and increased for sharp Bv76 reconstructions. Subjective QIR level preference varied kernel depending, preferred combinations were: Bv48/Q4, Bv60/Q2, Bv76/Q3. Interrater agreement was excellent. Sharp kernels benefited most from noise reduction of higher QIR levels in lower extremity PCD-CTA. In sum, QIR level 3 provided the best objective and subjective image quality results.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] CT coronary angiography: Influence of different cardiac reconstruction intervals on image quality and diagnostic accuracy
    Dewey, Marc
    Teige, Florian
    Rutsch, Wolfgang
    Schink, Tania
    Hamm, Bernd
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 67 (01) : 92 - 99
  • [42] Automatic spectral imaging protocol selection combined with iterative reconstruction can enhance image quality and decrease radiation and contrast dosage in abdominal CT angiography
    Xiao-Ping Yin
    Bu-Lang Gao
    Cai-Ying Li
    Zi-Wei Zuo
    Ying-Jin Xu
    Jia-Ning Wang
    Huai-Jun Liu
    Guang-Lu Liang
    Japanese Journal of Radiology, 2018, 36 : 345 - 350
  • [43] Automatic spectral imaging protocol selection combined with iterative reconstruction can enhance image quality and decrease radiation and contrast dosage in abdominal CT angiography
    Yin, Xiao-Ping
    Gao, Bu-Lang
    Li, Cai-Ying
    Zuo, Zi-Wei
    Xu, Ying-Jin
    Wang, Jia-Ning
    Liu, Huai-Jun
    Liang, Guang-Lu
    JAPANESE JOURNAL OF RADIOLOGY, 2018, 36 (05) : 345 - 350
  • [44] Intraindividual Evaluation of the Influence of Iterative Reconstruction and Filter Kernel on Subjective and Objective Image Quality in Computed Tomography of the Brain
    Buhk, J. H.
    Laqmani, A.
    von Schultzendorff, H. C.
    Hammerle, D.
    Sehner, S.
    Adam, G.
    Fiehler, J.
    Nagel, H. D.
    Regier, M.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2013, 185 (08): : 741 - 748
  • [45] Comprehensive Size- and Kernel-Dependent Comparison of Image Quality Between Photon-Counting and Energy Integrating CT
    Bhattarai, M.
    Bache, S.
    Abadi, E.
    Samei, E.
    MEDICAL PHYSICS, 2022, 49 (06) : E591 - E591
  • [46] Thin slice photon-counting CT coronary angiography compared to conventional CT: Objective image quality and clinical radiation dose assessment
    van der Bie, Judith
    Bos, Daniel
    Dijkshoorn, Marcel L.
    Booij, Ronald
    Budde, Ricardo P. J.
    van Straten, Marcel
    MEDICAL PHYSICS, 2024, 51 (04) : 2924 - 2932
  • [47] Improving image quality with model-based iterative reconstruction at quarter of nominal dose in upper abdominal CT
    Zhang, Xirong
    Chen, Jing
    Yu, Nan
    Ren, Zhanli
    Tian, Qian
    Tian, Xin
    He, Taiping
    Guo, Changyi
    BRITISH JOURNAL OF RADIOLOGY, 2018, 92 (1093):
  • [48] Low-dose photon-counting CT with penalized-likelihood basis-image reconstruction: image quality evaluation
    Persson, Mats U.
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [49] CT coronary angiography: Image quality with sinogram-affirmed iterative reconstruction compared with filtered back-projection
    Wang, R.
    Schoepf, U. J.
    Wu, R.
    Gibbs, K. P.
    Yu, W.
    Li, M.
    Zhang, Z.
    CLINICAL RADIOLOGY, 2013, 68 (03) : 272 - 278
  • [50] Iterative Reconstruction to Preserve Image Quality and Diagnostic Accuracy at Reduced Radiation Dose in Coronary CT Angiography An Intraindividual Comparison
    Yin, Wei-Hua
    Lu, Bin
    Li, Nan
    Han, Lei
    Hou, Zhi-Hui
    Wu, Run-Ze
    Wu, Yong-Jian
    Niu, Hong-Xia
    Jiang, Shi-Liang
    Krazinski, Aleksander W.
    Ebersberger, Ullrich
    Meinel, Felix G.
    Schoepf, U. Joseph
    JACC-CARDIOVASCULAR IMAGING, 2013, 6 (12) : 1239 - 1249