Combined influence of quantum iterative reconstruction level and kernel sharpness on image quality in photon counting CT angiography of the upper leg

被引:0
|
作者
Krompass, Kristina [1 ]
Goldbrunner, Florian Andreas [1 ]
Hartung, Viktor [1 ]
Erguen, Sueleyman [2 ]
Peter, Dominik [3 ]
Hendel, Robin [1 ]
Huflage, Henner [1 ]
Patzer, Theresa Sophie [1 ]
Hennes, Jan-Lucca [1 ]
Bley, Thorsten Alexander [1 ]
Grunz, Jan-Peter [1 ,4 ]
Gruschwitz, Philipp [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Univ Wurzburg, Inst Anat & Cell Biol, Wurzburg, Germany
[3] Univ Hosp Wurzburg, Dept Gen Visceral Transplant Vasc & Pediat Surg, Wurzburg, Germany
[4] Univ Wisconsin Madison, Dept Radiol, Madison, WI 53792 USA
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
关键词
ARTERIAL OCCLUSIVE DISEASE; COMPUTED-TOMOGRAPHY; PERFORMANCE; MANAGEMENT;
D O I
10.1038/s41598-024-79188-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Aim was to evaluate the influence of different quantum iterative reconstruction (QIR) levels on the image quality of femoral photon-counting CT angiographies (PCD-CTA). Ultra-high resolution PCD-CTA were obtained from both extremities of five extracorporeally-perfused cadavers using constant tube voltage and maximum radiation dose (71.2 +/- 11.0 mGy). Images were reconstructed with three kernels (Bv48, Bv60, Bv76) and the four available levels of QIR. Signal attenuation in the arterial lumen, muscle, and fat were measured. Contrast-to-noise ratios (CNR) and blurring scores were calculated for objective assessment. Six radiologists evaluated the subjective image quality using a pairwise comparison tool. Higher QIR level resulted in a decisive image noise reduction, especially with sharper convolution kernels (Bv60: Q1 11.5 +/- 6.3 HU vs. Q4 8.4 +/- 2.6 HU; p < 0.001). Largest improvement of CNR was recorded with ultra-sharp reconstructions (Bv76: Q1 20.2 +/- 4.4 vs. Q4 28.0 +/- 3.5; p < 0.001). Blurring decreased with higher QIR levels for soft Bv48, remained constant for medium Bv60, and increased for sharp Bv76 reconstructions. Subjective QIR level preference varied kernel depending, preferred combinations were: Bv48/Q4, Bv60/Q2, Bv76/Q3. Interrater agreement was excellent. Sharp kernels benefited most from noise reduction of higher QIR levels in lower extremity PCD-CTA. In sum, QIR level 3 provided the best objective and subjective image quality results.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] ASSESSMENT OF CLINICAL IMAGE QUALITY IN PAEDIATRIC ABDOMINAL CT EXAMINATIONS: DEPENDENCY ON THE LEVEL OF ADAPTIVE STATISTICAL ITERATIVE RECONSTRUCTION (ASIR) AND THE TYPE OF CONVOLUTION KERNEL
    Larsson, Joel
    Bath, Magnus
    Ledenius, Kerstin
    Caisander, Hakan
    Thilander-Klang, Anne
    RADIATION PROTECTION DOSIMETRY, 2016, 169 (1-4) : 123 - 129
  • [32] Toward truly combined PET/CT imaging using PET detectors and photon counting CT with iterative reconstruction implementing physical detector response
    Thibaudeau, Christian
    Berard, Philippe
    Tetrault, Marc-Andre
    Leroux, Jean-Daniel
    Bergeron, Melanie
    Fontaine, Rejean
    Lecomte, Roger
    MEDICAL PHYSICS, 2012, 39 (09) : 5697 - 5707
  • [33] Improved image quality and low radiation dose with hybrid iterative reconstruction with 80 kV CT pulmonary angiography
    Laqmani, Azien
    Regier, Marc
    Veldhoen, Simon
    Backhaus, Alexandra
    Wassenberg, Felicia
    Sehner, Susanne
    Groth, Michael
    Nagel, Hans-Dieter
    Adam, Gerhard
    Henes, Frank O.
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (10) : 1962 - 1969
  • [34] Adaptive Statistical Iterative Reconstruction in CT Angiography for Suspected Pulmonary Embolism: Effect on Objective and Subjective Image Quality
    Ridge, C.
    Litmanovich, D.
    Pianykh, O.
    Wilcox, C.
    Boiselle, P.
    Raptopoulos, V
    Bankier, A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [35] A Hybrid Iterative Reconstruction Algorithm That Improves the Image Quality of Low-Tube-Voltage Coronary CT Angiography
    Oda, Seitaro
    Utsunomiya, Daisuke
    Funama, Yoshinori
    Yonenaga, Kazuchika
    Namimoto, Tomohiro
    Nakaura, Takeshi
    Yamashita, Yasuyuki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05) : 1126 - 1131
  • [36] Impact of Increasing Levels of Advanced Iterative Reconstruction on Image Quality in Low-Dose Cardiac CT Angiography
    Kroepil, P.
    Bigdeli, A. H.
    Nagel, H. D.
    Antoch, G.
    Cohnen, M.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (06): : 567 - 575
  • [37] Reducing CT radiation dose with iterative reconstruction algorithms: The influence of scan and reconstruction parameters on image quality and CTDIvol
    Klink, Thorsten
    Obmann, Verena
    Heverhagen, Johannes
    Stork, Alexander
    Adam, Gerhard
    Begemann, Philipp
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (09) : 1645 - 1654
  • [38] Image quality improvement of a one-step spectral CT reconstruction on a prototype photon-counting scanner
    Rodesch, Pierre-Antoine
    Si-Mohamed, Salim A.
    Lesaint, Jerome
    Douek, Philippe C.
    Rit, Simon
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (01):
  • [39] Potential of employing a quantum iterative reconstruction algorithm for ultra-high-resolution photon-counting detector CT of the hip
    Huflage, H.
    Grunz, J. -P
    Kunz, A. S.
    Patzer, T. S.
    Sauer, S. T.
    Christner, S. A.
    Petritsch, B.
    Erguen, S.
    Bley, T. A.
    Luetkens, K. S.
    RADIOGRAPHY, 2023, 29 (01) : 44 - 49
  • [40] Quantum Iterative Reconstruction for Low-Dose Ultra-High-Resolution Photon-Counting Detector CT of the Lung
    Sartoretti, Thomas
    Racine, Damien
    Mergen, Victor
    Jungblut, Lisa
    Monnin, Pascal
    Flohr, Thomas G.
    Martini, Katharina
    Frauenfelder, Thomas
    Alkadhi, Hatem
    Euler, Andre
    DIAGNOSTICS, 2022, 12 (02)