Finite element analysis of biomechanical investigation on diverse internal fixation techniques in oblique lumbar interbody fusion

被引:2
|
作者
Yu, Qi [1 ,2 ]
Zou, Zhuo Lin [3 ]
Lu, Hui Gen [2 ]
Pan, Xue Kang [2 ]
Hu, Xu Qi [2 ]
Shen, Zhong Hai [2 ]
机构
[1] Haining Peoples Hosp, Dept Orthopaed, Jiaxing 314400, Zhejiang, Peoples R China
[2] Jiaxing Univ, Affiliated Hosp 2, Dept Orthopaed, Jiaxing 314001, Zhejiang, Peoples R China
[3] Jiaxing Univ, Hosp Jiaxing 1, Affiliated Hosp, Dept Infect Dis, Jiaxing 314001, Zhejiang, Peoples R China
关键词
Biomechanical study; Lumbar spine; Oblique lumbar interbody fusion; Adjacent segment degeneration; Finite element analysis; SURGERY;
D O I
10.1186/s12891-024-07887-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background To establish a three-dimensional finite element model of the lumbar spine and investigate the impact of different fixation techniques on the biomechanical characteristics of oblique lumbar interbody fusion (OLIF). Methods The study aimed to establish and validate a comprehensive three-dimensional model of the lower lumbar spine (L3-S1) using the finite element method. L4-L5 was selected as the surgical segment, and four distinct OLIF surgical models were constructed: Stand-alone (SA), unilateral cortical bone trajectory screw (UCBT), bilateral cortical bone trajectory screw (BCBT), and bilateral pedicle screw (BPS). The models were underwent a pure moment of 10N center dot m to simulate lumbar extension, flexion, left bending, right bending, left and right rotation movements. Subsequently, the range of motion (ROM), cage stress, and fixation stress were calculated. Results In the L3-L5 segment, the BCBT group showed the most limited range of motion (ROM) under exercise load, indicating superior stability within this group. The ROM and cage stress values were found to be highest in the SA group. In contrast, the cage and internal fixation stress in the BPS group were observed to be lowest (9.91 similar to 53.83MPa, 44.93 similar to 84.85 MPa). With the exception of right bending and right rotation, the UCBT group demonstrated higher levels of internal fixation stress (102.20 similar to 164.62 MPa). Conclusions The study found that OLIF-assisted internal fixation improved segmental stability and reduced cage stress. The BPS group had advantages over the CBT group in preventing endplate damage and reducing the risk of cage subsidence. However, BCBT group has distinct merits in maintaining surgical segment stability, distributing stress load on the spinal motor unit, and reducing the likelihood of adjacent segment degeneration (ASD).
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Biomechanical Analysis of Lateral Lumbar Interbody Fusion Constructs with Various Fixation Options: Based on a Validated Finite Element Model
    Zhang, Zhenjun
    Fogel, Guy R.
    Liao, Zhenhua
    Sun, Yitao
    Liu, Weiqiang
    WORLD NEUROSURGERY, 2018, 114 : E1120 - E1129
  • [32] Biomechanical Evaluation of Lateral Lumbar Interbody Fusion with Various Fixation Options for Adjacent Segment Degeneration: A Finite Element Analysis
    Lee, Hyun Ji
    Lee, Sung-Jae
    Jung, Jong-myung
    Lee, Tae Hoon
    Jeong, Chandong
    Lee, Tae Jin
    Jang, Ji-eun
    Lee, Jae-Won
    WORLD NEUROSURGERY, 2023, 173 : E156 - E167
  • [33] Biomechanical study of two-level oblique lumbar interbody fusion with different types of lateral instrumentation: a finite element analysis
    Zhong, Yuan
    Wang, Yujie
    Zhou, Hong
    Wang, Yudong
    Gan, Ziying
    Qu, Yimeng
    Hua, Runjia
    Chen, Zhaowei
    Chu, Genglei
    Liu, Yijie
    Jiang, Weimin
    FRONTIERS IN MEDICINE, 2023, 10
  • [34] Comparative Biomechanical Analysis of Unilateral, Bilateral, and Lateral Pedicle Screw Implantation in Oblique Lumbar Interbody Fusion: A Finite Element Study
    Pan, Chien-Chou
    Lee, Cheng-Hung
    Chen, Kun-Hui
    Yen, Yu-Chun
    Su, Kuo-Chih
    BIOENGINEERING-BASEL, 2023, 10 (11):
  • [35] Biomechanical comparison of anterior lumbar interbody fusion: stand-alone interbody cage versus interbody cage with pedicle screw fixation - a finite element analysis
    Kyung-Chul Choi
    Kyeong-Sik Ryu
    Sang-Ho Lee
    Yeong Hyeon Kim
    Sung Jae Lee
    Chun-Kun Park
    BMC Musculoskeletal Disorders, 14
  • [36] Biomechanical comparison of anterior lumbar interbody fusion: stand-alone interbody cage versus interbody cage with pedicle screw fixation - a finite element analysis
    Choi, Kyung-Chul
    Ryu, Kyeong-Sik
    Lee, Sang-Ho
    Kim, Yeong Hyeon
    Lee, Sung Jae
    Park, Chun-Kun
    BMC MUSCULOSKELETAL DISORDERS, 2013, 14
  • [37] Oblique Lumbar Interbody Fixation A Biomechanical Study in Human Spines
    St Clair, Selvon
    Tan, Juay Seng
    Lieberman, Isador
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2012, 25 (04): : 183 - 189
  • [38] Letter to the Editor Regarding: "Biomechanical Comparison of Stand-Alone and Bilateral Pedicle Screw Fixation for Oblique Lumbar Interbody Fusion Surgery-A Finite Element Analysis"
    Tartara, Fulvio
    Cofano, Fabio
    Di Perna, Giuseppe
    Tancioni, Flavio
    Garbossa, Diego
    WORLD NEUROSURGERY, 2021, 150 : 248 - 249
  • [39] Effect of Interbody Implants on the Biomechanical Behavior of Lateral Lumbar Interbody Fusion: A Finite Element Study
    Shen, Hangkai
    Zhu, Jia
    Huang, Chenhui
    Xiang, Dingding
    Liu, Weiqiang
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (02)
  • [40] Biomechanical evaluation of three surgical scenarios of posterior lumbar interbody fusion by finite element analysis
    Xiao, Zhitao
    Wang, Liya
    Gong, He
    Zhu, Dong
    BIOMEDICAL ENGINEERING ONLINE, 2012, 11