Sensitivity Analysis of Soil Parameters Influencing Ground Settlement in Top-Down Metro Station Excavations

被引:0
|
作者
Alireza Shafiei [1 ]
Mohammad Hosein Dehnad [1 ]
机构
[1] University of Qom,Department of Engineering
关键词
Ground settlement; Metro station; Top-down method; Underground structures; PLAXIS software;
D O I
10.1007/s40515-025-00551-6
中图分类号
学科分类号
摘要
The present research investigates a case study employing a top-down method, while incorporating both analytical and empirical approaches for the assessment of ground deformation. The investigation focuses on the settlement results derived from numerical methods. The results obtained from the modeling and analysis indicate that the maximum settlement occurs above the top slab, with ground settlement in the top-down excavation method measured at 12.3 mm. Additionally, soil parameters were subjected to a sensitivity analysis concerning hardening behavior. The sensitivity analysis revealed that an increase in the elastic modulus has the most significant impact on reducing ground settlement. To measure the settlement of the ground surface, settlement measuring pins have been installed at the entrance of the station located in the access tunnel. The settlement data obtained from the ENW-05 pin indicates a value of 4 mm. The discrepancy between this value and the settlement derived from the numerical analysis can be attributed to variations in the loading on the station and its sides, as well as the installation of settlement pins outside the station, which are situated in the access tunnel near the central core of the station.
引用
收藏
相关论文
共 23 条
  • [21] The Operational and Reservoir Parameters Influencing the Performance of Top-Down In Situ Combustion in Fractured Reservoirs: 2D Block-Scale Simulation of Networked Fractures
    Fatemi, S. M.
    Kharrat, R.
    Vossoughi, S.
    PETROLEUM SCIENCE AND TECHNOLOGY, 2012, 30 (03) : 256 - 270
  • [22] Experimental study on shear-resistance properties of the concrete-filled steel tubular frame joint of Gong Yuan Qian station of Guangzhou Metro constructed by cut-cover and top-down method
    He, Shaohui
    Zhang, Mi
    Yu, Zhefu
    Wu, Mingquan
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2000, 21 (02): : 20 - 27
  • [23] Top-Down Approach for the Deposition of Photoactive (Na0.5Bi0.5)TiO3-Based Heterojunctions by Flame Spray: Analysis of Deposition Parameters
    Gutierrez-Perez, A. I.
    Ayala-Ayala, M. T.
    Mora-Garcia, A. G.
    Hernandez-Navarro, C.
    Perez, S.
    Diaz-Real, J. A.
    Hernandez, J. Gonzalez
    Munoz-Saldana, J.
    JOURNAL OF THERMAL SPRAY TECHNOLOGY, 2023, 32 (07) : 1909 - 1925