Adaptive non-parametric kernel density estimation for under-frequency load shedding with electric vehicles and renewable power uncertainty

被引:0
|
作者
Renhai, Feng [1 ]
Khan, Wajid [1 ]
Tariq, Afshan [1 ]
Abbas, Muhammad [1 ]
Yousaf, Muhammad Zain [2 ,3 ,4 ]
Aziz, Abdul [5 ]
Bajaj, Mohit [6 ,7 ,8 ]
Abdullah, Mustafa [9 ]
Tuka, Milkias [10 ]
机构
[1] Tianjin Univ, Sch Elect & Informat Engn, Tianjin 300072, Peoples R China
[2] Zhejiang Univ, Ctr Renewable Energy & Micro, Zhuji 311816, Zhejiang, Peoples R China
[3] Hubei Univ Automot Technol, Sch Elect & Informat Engn, Shiyan, Peoples R China
[4] Zhejiang Univ, Sch Aeronaut & Astronaut, Hangzhou 310027, Zhejiang, Peoples R China
[5] CECOS Univ IT & Emerging Sci, Peshawar, KPK, Pakistan
[6] Graph Era, Dept Elect Engn, Dehra Dun 248002, India
[7] Univ Business & Technol, Coll Engn, Jeddah 21448, Saudi Arabia
[8] Graph Era Hill Univ, Dehra Dun 248002, India
[9] Al Ahliyya Amman Univ, Fac Engn, Hourani Ctr Appl Sci Res, Elect vehicles Engn Dept, Amman, Jordan
[10] ASTU, Dept Elect & Comp Engn, Addis Ababa, Ethiopia
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
Electric vehicle; Robust optimization; Under-frequency load shedding; Uncertainty Estimation; Wind power;
D O I
10.1038/s41598-025-94419-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
As power systems around the world shift to incorporate more renewable energy sources, particularly wind power, maintaining grid stability becomes increasingly challenging due to the inherent variability of these sources. This paper introduces a novel bi-level robust optimization framework that enhances the capabilities of adaptive Under-Frequency Load Shedding (AUFLS) in managing the uncertainties brought by high penetration of wind energy and dynamic participation of electric vehicles (EVs). Central to this framework is an innovative adaptive non-parametric Kernel Density Estimation (AAKDE) technique, which sharpens the accuracy of wind power fluctuation predictions. This method enables more precise and efficient control of load-shedding events, which is crucial for preventing frequency drops that can lead to grid instability. This research proposes a strategic shedding queue mechanism that systematically prioritizes the discharge of EVs based on their real-time state-of-charge and charging behavior. This prioritization minimizes user discomfort and taps into the potential of EVs as flexible energy resources, thus providing substantial support to grid operations. To enhance the responsiveness of our AUFLS approach, we integrate a reinforcement learning model that adjusts in real time to grid conditions, optimizing decision-making for frequency stabilization. Our extensive MATLAB/SIMULINK simulations on an upgraded IEEE 39 bus test system demonstrate a significant reduction in load shedding requirements. Compared to traditional AUFLS methods, our approach cuts load shedding by over 50%, effectively maintains system frequency within safe operational limits, and shows superior performance in scenarios of high renewable variability and EV integration. This research highlights the potential of adaptive non-parametric methods in transforming AUFLS strategies, paving the way for smarter, more resilient power systems equipped to handle the complexities of modern energy landscapes.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Non-Parametric Kernel Density Estimation for the Prediction of Neoadjuvant Chemotherapy Outcomes
    Wanderley, Maria Fernanda B.
    Braga, Antonio P.
    Mendes, Eduardo M. A. M.
    Natowicz, Rene
    Rouzier, Roman
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 1775 - 1778
  • [32] Event-Based Under-Frequency Load Shedding Scheme in a Standalone Power System
    Hong, Ying-Yi
    Hsiao, Chih-Yang
    ENERGIES, 2021, 14 (18)
  • [33] Non-parametric estimation for aggregated functional data for electric load monitoring
    Dias, Ronaldo
    Garcia, Nancy L.
    Martarelli, Angelo
    ENVIRONMETRICS, 2009, 20 (02) : 111 - 130
  • [34] Coordination between load shedding for safety and stability control and under-frequency load shedding in a small weak receiving power system
    Jia, M. (jia_mengmeng@126.com), 1600, Automation of Electric Power Systems Press (38):
  • [35] Adaptive Under-frequency Load Shedding Strategy of Power Grid with Large-scale DFIG Wind Turbines Participating in Frequency Regulation
    Li S.
    Lyu X.
    Zhong H.
    Long Q.
    Xie W.
    Shu Z.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2019, 43 (15): : 109 - 115
  • [36] Optimal Estimation of Under-Frequency Load Shedding Scheme Parameters by Considering Virtual Inertia Injection
    Bustamante-Mesa, Santiago
    Gonzalez-Sanchez, Jorge W.
    Saldarriaga-Zuluaga, Sergio D.
    Lopez-Lezama, Jesus M.
    Munoz-Galeano, Nicolas
    ENERGIES, 2024, 17 (02)
  • [37] Impact of Synchrophasor Estimation Algorithms in ROCOF-Based Under-Frequency Load-Shedding
    Zuo, Yihui
    Frigo, Guglielmo
    Derviskadic, Asja
    Paolone, Mario
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2020, 35 (02) : 1305 - 1316
  • [38] Research of modeling method based on non-parametric kernel density estimation of probability of wind power fluctuations
    Yang, Nan
    Zhou, Zheng
    Chen, Daojun
    Wang, Xuan
    Li, Hongsheng
    Li, Suoya
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2019, 40 (07): : 2028 - 2035
  • [39] An extended quasi monte carlo probabilistic load flow method based on non-parametric kernel density estimation
    Fang, Sidun
    Cheng, Haozhong
    Xu, Guodong
    Yao, Liangzhong
    Zeng, Pingliang
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2015, 39 (07): : 21 - 27
  • [40] Unit Commitment With Analytical Under-Frequency Load-Shedding Constraints for Island Power Systems
    Rajabdorri, Mohammad
    Rouco, Almudena
    Sigrist, Lukas
    Lobato, Enrique
    IEEE ACCESS, 2024, 12 : 72337 - 72344