A novel personalized homogenous finite element model to predict the pull-out strength of cancellous bone screws

被引:0
|
作者
Rouyin, Alireza [1 ]
Einafshar, Mohammadjavad [2 ]
Arjmand, Navid [1 ]
机构
[1] Sharif Univ Technol, Dept Mech Engn, Tehran 111559567, Iran
[2] Aalborg Univ, Dept Mat & Prod, Aalborg, Denmark
来源
关键词
Orthopedic screw; Bone screw pull-out strength; Personalized finite element analysis; Heterogeneous material mapping; Homogenous finite element; Material assignment; MISPLACED PEDICLE SCREWS; TRABECULAR BONE; DENSITY; BEHAVIOR; DESIGN; SPINE;
D O I
10.1186/s13018-024-05169-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Orthopedic surgeries often involve the insertion of bone screws for various fixation systems. The risk of postoperative screw loosening is usually assessed through experimental or finite element (FE) evaluations of the screw pull-out strength. FE simulations are based on either personalized complex but accurate heterogeneous modeling or non-personalized simple but relatively less accurate homogeneous modeling. This study aimed to develop and validate a novel personalized computed tomography (CT)-based homogeneous FE simulation approach to predict the pull-out force of cancellous bone screws. Methods Twenty FE simulations of L1-L5 vertebral screw pull-out tests were conducted, i.e., 10 heterogeneous and 10 homogenous models. Screws were inserted into the lower-middle region of vertebrae. In our novel homogeneous model, the region around approximately twice the diameter of the screw was used as a bone material reference volume. Subsequently, the overall material property of this region was homogeneously attributed to the entire vertebra, and pull-out simulations were conducted. Results The mean error of the predicted pull-out forces by our novel homogenous simulations was similar to 7.9% with respect to our heterogeneous model. When solely the cancellous bone was involved during the pull-out process (i.e., for L1, L2, and L3 vertebral bodies whose cortical bone in the inferior region is thin), the novel homogenous model yielded small mean error of < 6.0%. This error, however, increased to similar to 11% when the screw got involved to the cortical bone (for L4 and L5 vertebrae whose cortical bone in the inferior region is thick). Conclusion The proposed personalized CT-based homogenous model was highly accurate in estimating the pullout force especially when only the cancellous bone was involved with the screw.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Screw inserting in different phase of cement affect the pull-out strength of cement augmented screws
    Iamthanaporn, Khanin
    Aonsong, Wachirakorn
    Tuntarattanapong, Pakjai
    Yuenyongviwat, Varah
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2022, 108 (08)
  • [42] Comparative pull-out strength of tapped and untapped pilot holes for bicortical anterior cervical screws
    Ronderos, JF
    Jacobowitz, R
    Sonntag, VKH
    Crawford, NR
    Dickman, CA
    SPINE, 1997, 22 (02) : 167 - 170
  • [43] Pull out strength of pedicle screw in normal and osteoporotic cancellous bone models
    Varghese, Vicky
    Venkatesh, K.
    Kumar, G. Saravana
    2014 IEEE CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2014, : 458 - 463
  • [44] Cord pull-out tests: 3D finite element simulations
    Kocak, S.
    Pidaparti, R.M.V.
    Polymers and Polymer Composites, 2000, 8 (02) : 77 - 85
  • [45] Cord pull-out tests: 3D finite element simulations
    Kocak, S
    Pidaparti, RMV
    POLYMERS & POLYMER COMPOSITES, 2000, 8 (02): : 77 - 85
  • [46] Finite Element Analysis of the Pull-out Specimens of Steel Reinforced Lightweight Concrete
    Zhang, Jianwen
    Guo, Shihui
    PROGRESS IN STRUCTURE, PTS 1-4, 2012, 166-169 : 514 - 519
  • [47] NON-LINEAR FINITE-ELEMENT ANALYSIS OF PULL-OUT TEST
    OTTOSEN, NS
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1981, 107 (04): : 591 - 603
  • [48] Finite element Simulation of perfect bonding for single fiber pull-out test
    Wei, Gaufeng
    Liu, Guoyong
    Xu, Chonghai
    Sun, Xiaoqiang
    MATERIALS PROCESSING TECHNOLOGY, PTS 1-3, 2012, 418-420 : 509 - 512
  • [49] Incremental finite element delamination model for fibre pull-out tests of elastomer-matrix composites
    Frankl, Siegfried
    Pletz, Martin
    Schuecker, Clara
    3RD INTERNATIONAL CONFERENCE ON STRUCTURAL INTEGRITY (ICSI 2019), 2019, 17 : 51 - 57
  • [50] Comparison of Pull-out Strength for Different Bone Block Length in a Porcine Anterior Cruciate Ligament Model
    Posner, M. A. J. Matthew
    Owens, L. T. C. Brett
    Johnson, Paul
    Masciello, Noreen
    Cameron, Kenneth
    Roach, Christopher
    Svoboda, Steven
    Floersheim, Bruce
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2014, 2 (05): : 1 - 5