Performance of a point-of-care ultrasound platform for artificial intelligence-enabled assessment of pulmonary B-lines

被引:0
|
作者
Labaf, Ashkan [1 ]
ahman-Persson, Linda [2 ]
Husu, Leo Silven [2 ]
Smith, J. Gustav [1 ,3 ]
Ingvarsson, Annika [1 ]
Evaldsson, Anna Werther [1 ]
机构
[1] Lund Univ, Skane Univ Hosp, Dept Clin Sci Lund, Sect Heart Failure & Valvular Dis,Cardiol, Klinikgatan 15, S-22185 Lund, Sweden
[2] Skane Univ Hosp, Dept Internal & Emergency Med, Malmo, Sweden
[3] Univ Gothenburg, Inst Med, Dept Mol & Clin Med, Gothenburg, Sweden
关键词
Lung ultrasound; B-lines; Artificial intelligence; POCUS; LUNG ULTRASOUND; HEART-FAILURE; AGREEMENT;
D O I
10.1186/s12947-025-00338-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The incorporation of artificial intelligence (AI) into point-of-care ultrasound (POCUS) platforms has rapidly increased. The number of B-lines present on lung ultrasound (LUS) serve as a useful tool for the assessment of pulmonary congestion. Interpretation, however, requires experience and therefore AI automation has been pursued. This study aimed to test the agreement between the AI software embedded in a major vendor POCUS system and visual expert assessment. Methods This single-center prospective study included 55 patients hospitalized for various respiratory symptoms, predominantly acutely decompensated heart failure. A 12-zone protocol was used. Two experts in LUS independently categorized B-lines into 0, 1-2, 3-4, and >= 5. The intraclass correlation coefficient (ICC) was used to determine agreement. Results A total of 672 LUS zones were obtained, with 584 (87%) eligible for analysis. Compared with expert reviewers, the AI significantly overcounted number of B-lines per patient (23.5 vs. 2.8, p < 0.001). A greater proportion of zones with > 5 B-lines was found by the AI than by the reviewers (38% vs. 4%, p < 0.001). The ICC between the AI and reviewers was 0.28 for the total sum of B-lines and 0.37 for the zone-by-zone method. The interreviewer agreement was excellent, with ICCs of 0.92 and 0.91, respectively. Conclusion This study demonstrated excellent interrater reliability of B-line counts from experts but poor agreement with the AI software embedded in a major vendor system, primarily due to overcounting. Our findings indicate that further development is needed to increase the accuracy of AI tools in LUS.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Use of artificial intelligence by novice users to enable accurate point-of-care echocardiographic assessment of left ventricular ejection fraction
    Dadon, Z.
    Orlev, A.
    Steinmetz, Y.
    Butnaru, A.
    Rosenmann, D.
    Wolak, A.
    Glikson, M.
    Gottlieb, S.
    Alpert, E. A.
    EUROPEAN HEART JOURNAL, 2022, 43 : 3 - 3
  • [42] A Response to "Diagnostic Performance of Wells Score Combined With Point-of-care Lung and Venous Ultrasound in Suspected Pulmonary Embolism"
    Ehrman, Robert R.
    Gallien, John Z.
    ACADEMIC EMERGENCY MEDICINE, 2017, 24 (04) : 496 - 497
  • [43] Ultrasound B-lines in the evaluation of interstitial lung disease in patients with systemic sclerosis: Cut-off point definition for the presence of significant pulmonary fibrosis
    Tardella, Marika
    Di Carlo, Marco
    Carotti, Marina
    Filippucci, Emilio
    Grassi, Walter
    Salaffi, Fausto
    MEDICINE, 2018, 97 (18)
  • [44] A Stress Test of Artificial Intelligence: Can Deep Learning Models Trained From Formal Echocardiography Accurately Interpret Point-of-Care Ultrasound?
    Crockett, David
    Kelly, Christopher
    Brundage, James
    Jones, Jamal
    Ockerse, Patrick
    JOURNAL OF ULTRASOUND IN MEDICINE, 2022, 41 (12) : 3003 - 3012
  • [45] Use of artificial intelligence for point-of-care echocardiographic assessment of left ventricular ejection fraction among COVID-19 patients
    Dadon, Z.
    Levi, N.
    Orlev, A.
    Belman, D.
    Butnaru, A.
    Glikson, M.
    Gottlieb, S.
    Alpert, E. A.
    EUROPEAN HEART JOURNAL, 2022, 43 : 4 - 4
  • [46] Diagnostic performance of qualitative ultrasound assessment for the interpretation of point-of-care gastric ultrasound to detect high gastric fluid volume: Letter to the editor
    Burbano, Mario Andres Zamudio
    JOURNAL OF CLINICAL ANESTHESIA, 2023, 86
  • [47] Artificial Intelligence-Enabled Assessment of Right Ventricular to Pulmonary Artery Coupling Refines Mortality Prediction in Patients With Severe Tricuspid Regurgitation Undergoing Transcatheter Tricuspid Valve Intervention
    Fortmeier, Vera
    Lachmann, Mark
    Stolz, Lukas
    Unterhuber, Matthias
    Kassar, Mohammad
    Gercek, Muhammed
    Koerber, Isabel
    Pfister, Roman
    Baldus, Stephan
    Laugwitz, Karl-Ludwig
    Windecker, Stephan
    Praz, Fabien
    Lurz, Phillip
    Hausleiter, Joerg
    Rudolph, Volker
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B63 - B63
  • [48] Health 360x Registry (H360xR): Artificial Intelligence (AI)-Enabled Equitable Access to Point-of-Care Decentralized Clinical Trials
    Obialo, Chamberlain I.
    Lee, Eva
    Ofili, Elizabeth O.
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2024, 35 (10):
  • [49] Artificial intelligence-based evaluation of carotid artery compressibility via point-of-care ultrasound in determining the return of spontaneous circulation during cardiopulmonary resuscitation
    Park, Subin
    Yoon, Hee
    Kang, Soo Yeon
    Jo, Ik Joon
    Heo, Sejin
    Chang, Hansol
    Park, Jong Eun
    Lee, Guntak
    Kim, Taerim
    Hwang, Sung Yeon
    Park, Soyoung
    Chung, Myung Jin
    RESUSCITATION, 2024, 202
  • [50] Can Artificial Intelligence Aid Diagnosis by Teleguided Point-of-Care Ultrasound? A Pilot Study for Evaluating a Novel Computer Algorithm for COVID-19 Diagnosis Using Lung Ultrasound
    Sultan, Laith R.
    Haertter, Allison
    Al-Hasani, Maryam
    Demiris, George
    Cary, Theodore W.
    Tung-Chen, Yale
    Sehgal, Chandra M.
    AI, 2023, 4 (04) : 875 - 887