A fluid temperature interpolation method for wide temperature range distributed flow calorimeter

被引:0
|
作者
Zhang, Tao [1 ]
Lv, Yiming [1 ]
Xie, Tiancheng [1 ]
Hu, Dongfang [1 ]
Xu, Jinxin [1 ]
Hou, Dexin [1 ]
Ding, Jiong [1 ]
机构
[1] China Jiliang Univ, Coll Metrol Measurement & Instrument, Xueyuan St 258, Hangzhou 310018, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2024年 / 95卷 / 10期
关键词
HEAT-TRANSFER COEFFICIENT; HYDROCARBON FUEL;
D O I
10.1063/5.0231588
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The distributed flow calorimeter is employed to measure reaction enthalpy, mixing enthalpy, and other thermodynamic parameters of hydrocarbon fuels. This information serves as a foundation for selecting and developing hydrocarbon fuels for hypersonic flight. The fluid temperature in the tube is a key factor in characterizing its thermodynamic behavior. Given the challenges of monitoring fluid temperature within a tube using current flow calorimetry, a distributed method for calculating fluid temperature in tubes under high-temperature conditions is proposed. This method realizes the interpolation of the enthalpy function of the experimental fluid through several sets of experiments with varying power levels. The fluid temperature in the tube is calculated by considering the microelement as the research object. First, the methodology for calculating fluid temperature in narrow pipes across a wide temperature range is presented. Second, the simulation model of the flow calorimeter is established, and the methodology is verified through numerical simulation. Finally, a flow calorimetric experimental device is setup. N-decane was used as the fluid in the experiment, and the temperature was calculated, and the calculated results were compared with the NIST data. In the temperature range of 295.50-609.38 K, the relative error range of the calculation of n-decane temperature is -0.61% to 1.24%. The experimental results show that the method can effectively estimate the fluid temperature of the distributed flow calorimeter.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] TEMPERATURE CONDUCTIVITY OF IRIDIUM OVER A WIDE TEMPERATURE-RANGE
    GELD, LP
    ZINOVEV, VE
    HIGH TEMPERATURE, 1972, 10 (03) : 588 - 589
  • [22] METHOD FOR MAINTAINING AND MEASURING CONSTANT POWER DISSIPATION TO A CALORIMETER CIRCUIT OVER A WIDE TEMPERATURE INTERVAL
    ROSENGREN, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1961, 32 (11): : 1264 - &
  • [23] Flow Stress of bcc Metals over a Wide Range of Temperature and Strain Rates
    Testa, Gabriel
    Bonora, Nicola
    Ruggiero, Andrew
    Iannitti, Gianluca
    METALS, 2020, 10 (01)
  • [24] Temperature behavior of the free activation energy of viscous flow of glass-forming melts in a wide temperature range
    D. S. Sanditov
    S. B. Munkueva
    A. A. Mashanov
    B. D. Sanditov
    Glass Physics and Chemistry, 2012, 38 : 379 - 385
  • [25] Temperature behavior of the free activation energy of viscous flow of glass-forming melts in a wide temperature range
    Sanditov, D. S.
    Munkueva, S. B.
    Mashanov, A. A.
    Sanditov, B. D.
    GLASS PHYSICS AND CHEMISTRY, 2012, 38 (04) : 379 - 385
  • [26] Novel Actuator Driven with Phase Transition of Working Fluid for Uses in Wide Temperature Range
    Suzumori, K.
    Matsuoka, H.
    Wakimoto, S.
    2012 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2012, : 616 - 621
  • [27] DIELECTRIC-CONSTANTS OF FLUID MIXTURES OVER A WIDE-RANGE OF TEMPERATURE AND DENSITY
    HARVEY, AH
    PRAUSNITZ, JM
    JOURNAL OF SOLUTION CHEMISTRY, 1987, 16 (10) : 857 - 869
  • [28] Optical visualization of a fluid flow via the temperature controlling method
    Tanigawa, Risako
    Ishikawa, Kenji
    Yatabe, Kohei
    Oikawa, Yasuhiro
    Onuma, Takashi
    Niwa, Hayato
    OPTICS LETTERS, 2018, 43 (14) : 3273 - 3276
  • [29] A micromachined silicon capacitive temperature sensor for wide temperature range applications
    Ma, Hong-Yu
    Huang, Qing-An
    Qin, Ming
    Lu, Tingting
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2010, 20 (05)
  • [30] A current reference with wide temperature operation range and low temperature drift
    Ding, Liqiang
    Cai, Xiaowu
    Wang, Yang
    Han, Zhengsheng
    Li, Bo
    Zhao, Fazhan
    ELECTRONICS LETTERS, 2022, 58 (09) : 343 - 345