Alteration of Mastication Force via Intraoral Closed-Loop Electrical Stimulation

被引:0
|
作者
Zheng, Junxiang [1 ]
Jiang, Bing [2 ]
Biswas, Saurabh [3 ]
Lee, Su Young [4 ]
Bumann, Erin Ealba [5 ]
Lever, Teresa E. [6 ]
Kim, Jeonghee [7 ,8 ]
Park, Hangue [1 ,9 ,10 ]
机构
[1] Texas A&M Univ, Dept Elect & Comp Engn, College Stn, TX 77843 USA
[2] Utah Tech Univ, Dept Elect & Comp Engn, St George, UT 84770 USA
[3] Texas A&M Univ, Dept Biomed Engn, College Stn, TX 77843 USA
[4] Catholic Univ Korea, Seoul St Marys Dent Hosp, Coll Med, Dept Prosthodont, Seoul 06591, South Korea
[5] Univ Missouri, Sch Dent, Dept Oral & Craniofacial Sci, Kansas City, MO 64108 USA
[6] Univ Missouri, Sch Med, Dept Otolaryngol Head & Neck Surg, Columbia, MO 65212 USA
[7] Hanyang Univ, Dept Elect Engn, Dept Biomed Engn, Dept Artificial Intelligence, Seoul 04763, South Korea
[8] Hanyang Univ, Dept AI Semicond, Seoul 04763, South Korea
[9] Sungkyunkwan Univ, Dept Biomed Engn, Dept Intelligent Precis Healthcare Convergence, Suwon 16419, South Korea
[10] Sungkyunkwan Univ, Dept MetaBioHealth, Suwon 16419, South Korea
基金
新加坡国家研究基金会;
关键词
Force; Dentistry; Electrical stimulation; Teeth; Surface impedance; Muscles; Force measurement; Impedance; Aging; Tactile sensors; Mastication; tactile augmentation; closed-loop electrical stimulation; intraoral device; CHEWING RATE; SOLID FOOD; BITE FORCE; MUSCLES; TONGUE; SYSTEM; OVERDENTURES; MOVEMENTS; TEXTURES; FEEDBACK;
D O I
10.1109/TNSRE.2025.3535681
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Mastication plays an important role in effective food digestion and nutrient absorption. Therefore, regulating masticatory force in people with declining mastication function is significant for maintaining health and quality of life. In this study, we tested the effect of tactile augmentation on mastication force. To augment tactile feedback during mastication, we applied closed-loop electrical stimulation onto the mandibular vestibule using an intraoral tooth-borne electronic system. We hypothesized that closed-loop electrical stimulation, timed with mastication and applied to the nerves delivering tactile feedback to the brain, would evoke an increase in masticatory force. Experiments were completed using the intraoral system with six healthy human subjects who masticated soft and hard foods with and without stimulation during the experiment. Their mastication forces were recorded ten times per condition. The recorded mastication force profile showed that mastication force was higher with the harder food. Also, mastication force increased when electrical stimulation was applied, compared to the non-stimulated condition. These results support the hypothesis that tactile augmentation by intraoral closed-loop electrical stimulation will increase masticatory force. Other mastication parameters including period, spike width, and duty cycle are also changed by electrical stimulation. Further, stimulation left a strong aftereffect on these mastication parameters.
引用
收藏
页码:675 / 686
页数:12
相关论文
共 50 条
  • [41] Muscle enhancement using closed-loop electrical stimulation: Volitional versus induced torque
    Langzam, E.
    Nemirovsky, Y.
    Isakov, E.
    Mizrahi, J.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2007, 17 (03) : 275 - 284
  • [42] Closed-Loop Asynchronous Neuromuscular Electrical Stimulation Prolongs Functional Movements in the Lower Body
    Downey, Ryan J.
    Cheng, Teng-Hu
    Bellman, Matthew J.
    Dixon, Warren E.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2015, 23 (06) : 1117 - 1127
  • [43] Functional Electrical Stimulation as a Neuroprosthetic Methodology for Enabling Closed-loop Urinary Incontinence Treatment
    Wei, Xuan
    Rijkhoff, Nico J.
    Santa, Wesley A.
    Anderson, Joel A.
    Afshar, Pedram
    Schindeldecker, William J.
    Wika, Kent E.
    Barka, Noah D.
    Denison, Timothy J.
    2011 5TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2011, : 650 - 654
  • [44] Closed-Loop Cadence and Instantaneous Power Control on a Motorized Functional Electrical Stimulation Cycle
    Cousin, Christian A.
    Duenas, Victor H.
    Rouse, Courtney A.
    Bellman, Matthew J.
    Freeborn, Paul
    Fox, Emily J.
    Dixon, Warren E.
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2020, 28 (06) : 2276 - 2291
  • [45] Closed-loop identification of carotid sinus baroreflex transfer characteristics using electrical stimulation
    Kawada, T
    Sato, T
    Inagaki, M
    Shishido, T
    Tatewaki, T
    Yanagiya, Y
    Zheng, C
    Sugimachi, M
    Sunagawa, K
    JAPANESE JOURNAL OF PHYSIOLOGY, 2000, 50 (03): : 371 - 380
  • [46] Evoked Electromyography-Based Closed-Loop Torque Control in Functional Electrical Stimulation
    Zhang, Qin
    Hayashibe, Mitsuhiro
    Azevedo-Coste, Christine
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (08) : 2299 - 2307
  • [47] CLOSED-LOOP POSITIONING OF HEMIPLEGIC PATIENTS JOINT BY MEANS OF FUNCTIONAL ELECTRICAL-STIMULATION
    STANIC, U
    TRNKOCZY, A
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1974, BM21 (05) : 365 - 370
  • [48] Providing Slip Feedback for Closed-Loop Control of Myoelectric Prosthesis via Electrotactile Stimulation
    Bao, Linjun
    Zhang, Dingguo
    Xu, Heng
    Zhu, Xiangyang
    INTELLIGENT ROBOTICS AND APPLICATIONS, ICIRA 2015, PT I, 2015, 9244 : 319 - 328
  • [49] A Closed-loop MEMS Force Sensor with Adjustable Stiffness
    Maroufi, Mohammad
    Alemansour, Hamed
    Moheimani, S. O. Reza
    2017 IEEE CONFERENCE ON CONTROL TECHNOLOGY AND APPLICATIONS (CCTA 2017), 2017, : 438 - 443
  • [50] POSITION-FORCE SYNTHESIS OF CLOSED-LOOP LINKAGES
    HUANG, C
    ROTH, B
    JOURNAL OF MECHANICAL DESIGN, 1994, 116 (01) : 155 - 162