Alteration of Mastication Force via Intraoral Closed-Loop Electrical Stimulation

被引:0
|
作者
Zheng, Junxiang [1 ]
Jiang, Bing [2 ]
Biswas, Saurabh [3 ]
Lee, Su Young [4 ]
Bumann, Erin Ealba [5 ]
Lever, Teresa E. [6 ]
Kim, Jeonghee [7 ,8 ]
Park, Hangue [1 ,9 ,10 ]
机构
[1] Texas A&M Univ, Dept Elect & Comp Engn, College Stn, TX 77843 USA
[2] Utah Tech Univ, Dept Elect & Comp Engn, St George, UT 84770 USA
[3] Texas A&M Univ, Dept Biomed Engn, College Stn, TX 77843 USA
[4] Catholic Univ Korea, Seoul St Marys Dent Hosp, Coll Med, Dept Prosthodont, Seoul 06591, South Korea
[5] Univ Missouri, Sch Dent, Dept Oral & Craniofacial Sci, Kansas City, MO 64108 USA
[6] Univ Missouri, Sch Med, Dept Otolaryngol Head & Neck Surg, Columbia, MO 65212 USA
[7] Hanyang Univ, Dept Elect Engn, Dept Biomed Engn, Dept Artificial Intelligence, Seoul 04763, South Korea
[8] Hanyang Univ, Dept AI Semicond, Seoul 04763, South Korea
[9] Sungkyunkwan Univ, Dept Biomed Engn, Dept Intelligent Precis Healthcare Convergence, Suwon 16419, South Korea
[10] Sungkyunkwan Univ, Dept MetaBioHealth, Suwon 16419, South Korea
基金
新加坡国家研究基金会;
关键词
Force; Dentistry; Electrical stimulation; Teeth; Surface impedance; Muscles; Force measurement; Impedance; Aging; Tactile sensors; Mastication; tactile augmentation; closed-loop electrical stimulation; intraoral device; CHEWING RATE; SOLID FOOD; BITE FORCE; MUSCLES; TONGUE; SYSTEM; OVERDENTURES; MOVEMENTS; TEXTURES; FEEDBACK;
D O I
10.1109/TNSRE.2025.3535681
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Mastication plays an important role in effective food digestion and nutrient absorption. Therefore, regulating masticatory force in people with declining mastication function is significant for maintaining health and quality of life. In this study, we tested the effect of tactile augmentation on mastication force. To augment tactile feedback during mastication, we applied closed-loop electrical stimulation onto the mandibular vestibule using an intraoral tooth-borne electronic system. We hypothesized that closed-loop electrical stimulation, timed with mastication and applied to the nerves delivering tactile feedback to the brain, would evoke an increase in masticatory force. Experiments were completed using the intraoral system with six healthy human subjects who masticated soft and hard foods with and without stimulation during the experiment. Their mastication forces were recorded ten times per condition. The recorded mastication force profile showed that mastication force was higher with the harder food. Also, mastication force increased when electrical stimulation was applied, compared to the non-stimulated condition. These results support the hypothesis that tactile augmentation by intraoral closed-loop electrical stimulation will increase masticatory force. Other mastication parameters including period, spike width, and duty cycle are also changed by electrical stimulation. Further, stimulation left a strong aftereffect on these mastication parameters.
引用
收藏
页码:675 / 686
页数:12
相关论文
共 50 条
  • [11] Closed-loop control of the heart rate by electrical stimulation of the vagus nerve
    Marco Tosato
    Ken Yoshida
    Egon Toft
    Vitas Nekrasas
    Johannes J. Struijk
    Medical and Biological Engineering and Computing, 2006, 44 : 161 - 169
  • [12] Closed-Loop Functional Electrical Stimulation for Gait Training for Patients with Paraplegia
    Bouri, Mohamed
    Selfslagh, Aurelie
    Campos, Debora
    Yonamine, Seidi
    Donati, Ana R. C.
    Shokur, Solaiman
    2018 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2018, : 1489 - 1495
  • [13] Mechanomyography based closed-loop Functional Electrical Stimulation cycling system
    Woods, Billy
    Subramanian, Mahendran
    Shafti, Ali
    Faisal, A. Aldo
    2018 7TH IEEE INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB2018), 2018, : 179 - 184
  • [14] PyTES: A Python']Python toolbox for closed-loop transcranial electrical stimulation
    Xu, Jiachen
    Grosse-Wentrup, Moritz
    SOFTWAREX, 2023, 23
  • [15] Closed-loop control of the heart rate by electrical stimulation of the vagus nerve
    Tosato, Marco
    Yoshida, Ken
    Toft, Egon
    Nekrasas, Vitas
    Struijk, Johannes J.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (03) : 161 - 169
  • [16] AN ARTIFICIAL NEURAL SYSTEM FOR CLOSED-LOOP CONTROL OF LOCOMOTION PRODUCED VIA NEUROMUSCULAR ELECTRICAL-STIMULATION
    SEPULVEDA, F
    CLIQUET, A
    ARTIFICIAL ORGANS, 1995, 19 (03) : 231 - 237
  • [17] Closed-loop functional optogenetic stimulation
    Shriya S. Srinivasan
    Benjamin E. Maimon
    Maurizio Diaz
    Hyungeun Song
    Hugh M. Herr
    Nature Communications, 9
  • [18] TOWARD CLOSED-LOOP GASTROINTESTINAL STIMULATION
    Lo, Yi-Cao
    Huynh, Nhan
    Rouch, Joshua D.
    Dubrovsky, Genia
    Wang, Po-Min
    Dunn, James C.
    Liu, Wentai
    GASTROENTEROLOGY, 2018, 154 (06) : S321 - S321
  • [19] Closed-loop functional optogenetic stimulation
    Srinivasan, Shriya S.
    Maimon, Benjamin E.
    Diaz, Maurizio
    Song, Hyungeun
    Herr, Hugh M.
    NATURE COMMUNICATIONS, 2018, 9
  • [20] Closed-loop stimulation of sleep oscillations
    Ngo, H. -V.