Optical Frequency Sweeping Nonlinearity Measurement Based on a Calibration-free MZI

被引:0
|
作者
Sun, Pengwei [1 ,2 ,3 ,4 ]
Zhao, Bin [1 ,2 ,3 ,4 ]
Liu, Bo [1 ,2 ,3 ,4 ]
机构
[1] Chinese Acad Sci, Natl Key Lab Opt Field Manipulat Sci & Technol, Chengdu 610209, Peoples R China
[2] Chinese Acad Sci, Key Lab Sci & Technol Space Optoelect Precis Measu, Chengdu 610209, Peoples R China
[3] Chinese Acad Sci, Inst Opt & Elect, Chengdu 610209, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
calibration-free MZI; nonlinearity measurement; triangular FMCW LIDAR; DOMAIN REFLECTOMETRY; LINEARIZATION; RANGE; LIDAR;
D O I
10.3390/rs16244766
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Frequency sweeping linearity is essential for Frequency-Modulated Continuous Wave (FMCW) Light Detection and Ranging (LIDAR), as it impacts the ranging resolution and accuracy of the system. Pre-distortion methods can correct for frequency sweeping nonlinearity; however, residual minor nonlinearities can still degrade the system ranging resolution, especially at far distances. Therefore, the precise measurement of minor nonlinearities is particularly essential for long-range FMCW LIDAR. This paper proposes a calibration-free MZI for measuring optical frequency sweeping nonlinearity, which involves alternately inserting two short polarization-maintaining fibers with different delays into one arm of an MZI, and after two rounds of beat collection, the optical frequency sweep curve of the light source is accurately measured for nonlinearity evaluation. Using the proposed method, the nonlinearity of a frequency-swept laser source is measured to be 0.2113%, and the relative nonlinearity is 5.3560 x 10-5. With the measured frequency sweep curve, we simulate the beat signal and compare it with the collected beat signal in time and frequency domain, to verify the accuracy of the proposed method. A test conducted at 24.1 degrees C, 30.4 degrees C, 39.5 degrees C and 44.0 degrees C demonstrate the method's insensitivity to temperature fluctuations. Based on the proposed MZI, a tunable laser is pre-distorted and then used as light source of a FMCW lidar. A wall at 45 m and a building at 1.2 km are ranged by the lidar respectively. Before and after laser pre-distortion, the FWHM of echo beat spectrum are 25.635 kHz and 9.736 kHz for 45 m, 747.880 kHz and 22.012 kHz for 1.2 km.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] A Calibration-Free Crowdsourcing-Based Indoor Localization Solution
    Yin, Jie
    Wu, Ying
    Zhang, Xinxin
    Lu, Miao
    ADVANCES IN SERVICES COMPUTING, 2016, 10065 : 65 - 76
  • [42] A smartphone-based calibration-free portable urinalysis device
    Guo Dong
    Li Gen
    Miao Jia-qi
    Shen Ya-jing
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2021, 28 (12) : 3829 - 3837
  • [43] Calibration-Free Gaze Interfaces Based on Linear Smooth Pursuit
    Zeng, Zhe
    Siebert, Felix Wilhelm
    Venjakob, Antje Christine
    Roetting, Matthias
    JOURNAL OF EYE MOVEMENT RESEARCH, 2020, 13 (01): : 1 - 12
  • [44] Automatic Visual Acuity Measurement by Using a Calibration-free Eye Tracking System
    Murata, Noriaki
    Toda, Haruo
    Ubukata, Hokuto
    Sonobe, Takuma
    Hasegawa, Aino
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [45] Path length calibration-free optical spectrometer with multi-pass absorption cell based on frequency modulated continuous wave ranging system
    Konishi, Tomoharu
    Iiyama, Koichi
    Yoshii, Yotsumi
    OPTICS COMMUNICATIONS, 2021, 498
  • [46] Assessment of a Calibration-Free Method of Cuffless Blood Pressure Measurement: A Pilot Study
    Guo, Cheng-Yan
    Chang, Chia-Chi
    Wang, Kuan-Jen
    Hsieh, Tung-Li
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2023, 11 : 318 - 329
  • [47] Pressure Correction for Calibration-Free Measurement of Wavelength Modulation Spectroscopy in Atmospheric Environment
    Li Jin-yi
    Fan Hong-qing
    Tian Xin-li
    Li Hong-lian
    Wu Zhi-chao
    Song Li-mei
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40 (05) : 1407 - 1412
  • [48] Calibration-free temperature measurement by p-n junctions with varied current
    Department of Metrology, University of Kassel, D-34109 Kassel, Germany
    Proc. Est. Acad. Sci. Eng., 2007, 4 (409-422): : 409 - 422
  • [49] Calibration-free Gaze Tracking for Automatic Measurement of Visual Acuity in Human Infants
    Xiong, Chunshui
    Huang, Lei
    Liu, Changping
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 962 - 965
  • [50] High-Accuracy Calibration-Free Calorimeter for the Measurement of Low Power Losses
    Jafari, Armin
    Heijnemans, Michael
    Soleimanzadeh, Reza
    van Erp, Remco
    Samizadeh Nikoo, Mohammad
    Figini, Enea
    Karakaya, Furkan
    Matioli, Elison
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (01) : 23 - 28