Optical Frequency Sweeping Nonlinearity Measurement Based on a Calibration-free MZI

被引:0
|
作者
Sun, Pengwei [1 ,2 ,3 ,4 ]
Zhao, Bin [1 ,2 ,3 ,4 ]
Liu, Bo [1 ,2 ,3 ,4 ]
机构
[1] Chinese Acad Sci, Natl Key Lab Opt Field Manipulat Sci & Technol, Chengdu 610209, Peoples R China
[2] Chinese Acad Sci, Key Lab Sci & Technol Space Optoelect Precis Measu, Chengdu 610209, Peoples R China
[3] Chinese Acad Sci, Inst Opt & Elect, Chengdu 610209, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
calibration-free MZI; nonlinearity measurement; triangular FMCW LIDAR; DOMAIN REFLECTOMETRY; LINEARIZATION; RANGE; LIDAR;
D O I
10.3390/rs16244766
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Frequency sweeping linearity is essential for Frequency-Modulated Continuous Wave (FMCW) Light Detection and Ranging (LIDAR), as it impacts the ranging resolution and accuracy of the system. Pre-distortion methods can correct for frequency sweeping nonlinearity; however, residual minor nonlinearities can still degrade the system ranging resolution, especially at far distances. Therefore, the precise measurement of minor nonlinearities is particularly essential for long-range FMCW LIDAR. This paper proposes a calibration-free MZI for measuring optical frequency sweeping nonlinearity, which involves alternately inserting two short polarization-maintaining fibers with different delays into one arm of an MZI, and after two rounds of beat collection, the optical frequency sweep curve of the light source is accurately measured for nonlinearity evaluation. Using the proposed method, the nonlinearity of a frequency-swept laser source is measured to be 0.2113%, and the relative nonlinearity is 5.3560 x 10-5. With the measured frequency sweep curve, we simulate the beat signal and compare it with the collected beat signal in time and frequency domain, to verify the accuracy of the proposed method. A test conducted at 24.1 degrees C, 30.4 degrees C, 39.5 degrees C and 44.0 degrees C demonstrate the method's insensitivity to temperature fluctuations. Based on the proposed MZI, a tunable laser is pre-distorted and then used as light source of a FMCW lidar. A wall at 45 m and a building at 1.2 km are ranged by the lidar respectively. Before and after laser pre-distortion, the FWHM of echo beat spectrum are 25.635 kHz and 9.736 kHz for 45 m, 747.880 kHz and 22.012 kHz for 1.2 km.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Principles of building of "calibration-free" optical systems of biomedical diagnostics
    Kugeiko, MM
    BIOMEDICAL SYSTEMS AND TECHNOLOGIES II, PROCEEDINGS OF, 1998, 3199 : 273 - 282
  • [22] Optical Carrier Phase Sweeping Based RF Signal Frequency Measurement System
    Huang, Chongjia
    Chan, Erwin H. W.
    Hao, Peng
    Wang, Xudong
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2023, 35 (22) : 1243 - 1246
  • [23] A Calibration-Free Hybrid BCI Speller System Based on High-Frequency SSVEP and sEMG
    Zhang, Ruoqing
    Dong, Guoya
    Li, Meng
    Tang, Zhihua
    Chen, Xiaogang
    Cui, Hongyan
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2023, 31 : 3492 - 3500
  • [24] Calibration-free SSVEP-based BCI Switch
    Sastry, R., V
    Karthik, S.
    Adithya, R.
    Ravi, Aravind
    Indrapriyadarsini, S.
    Panwar, Gagandeep
    Ramakrishnan, A. G.
    2019 IEEE 16TH INDIA COUNCIL INTERNATIONAL CONFERENCE (IEEE INDICON 2019), 2019,
  • [25] Possibilities of a model performance improvement for the calibration-free temperature measurement based on pn-junctions
    Kanoun, O
    Horn, M
    Tränkler, HR
    IMTC/99: PROCEEDINGS OF THE 16TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS. 1-3, 1999, : 6 - 11
  • [26] Possibilities of a model performance improvement for the calibration-free temperature measurement based on pn-junctions
    Kanoun, Olfa
    Horn, Michael
    Traenkler, Hans-Rolf
    Conference Record - IEEE Instrumentation and Measurement Technology Conference, 1999, 1 : 6 - 11
  • [27] Model performance improvement for a calibration-free temperature measurement based on p-n junctions
    Kanoun, O
    Tränkler, HR
    SENSORS AND ACTUATORS A-PHYSICAL, 2002, 101 (03) : 275 - 282
  • [28] High frequency, calibration-free molecular measurements in situ in the living body
    Li, Hui
    Li, Shaoguang
    Dai, Jun
    Li, Chengcheng
    Zhu, Man
    Li, Hongxing
    Lou, Xiaoding
    Xia, Fan
    Plaxco, Kevin W.
    CHEMICAL SCIENCE, 2019, 10 (47) : 10843 - 10848
  • [29] A CALIBRATION-FREE METHOD FOR MEASUREMENT OF SOUND SPEED IN BIOLOGICAL TISSUE SAMPLES
    OPHIR, J
    LIN, T
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1988, 35 (05) : 573 - 577
  • [30] A Novel Calibration-Free Method of Measurement of Oxygen Saturation in Arterial Blood
    Reddy, K. Ashoka
    George, Boby
    Mohan, N. Madhu
    Kumar, V. Jagadeesh
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (05) : 1699 - 1705