Non-contact surface thermal deformation measurement based on chromatic confocal sensor

被引:0
|
作者
Mao, Xiaoxiao [1 ]
Xing, Zhiming [1 ]
Zhao, Bin [1 ]
Sun, Fei [1 ]
Gao, Xiumin [1 ]
机构
[1] Univ Shanghai Sci & Technol, Shanghai 200093, Peoples R China
关键词
chromatic confocal sensor; laser triangular displacement sensor; thermal deformation measure- ment; finite element method;
D O I
10.37190/oa240210
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Chromatic confocal sensors are widely used in chip processing, high-precision instrument manufacturing, industrial testing and other fields because of high-precision displacement recognitioncapabilities. This research combines a chromatic confocal device with resistance temperature detector for dynamic deformation measurement of heating pipeline. The system is suitable for the measuring range of 300 mu m and resolution can reach 0.3 mu m. Using finite element method to simulate thermal deformation of aluminium with a thickness of 2 mm, and obtaining simulation trends and results. The end face of aluminium is heated continuously and uniformly in experiment, recording the data of spectral, laser triangular displacement sensor, and temperature sensor at 10 degrees C intervals, respectively. And using Gaussian fitting algorithm to obtain spectral peaks, the corresponding thermal deformation is obtained through the relationship between wavelength and axial displacement. The results show that the experimental data of the chromatic confocal sensor is consistent with the laser triangular displacement sensor basically, with a maximum standard deviation of 1.06. In addition, simulation and experimental trends are consistent.
引用
收藏
页码:245 / 257
页数:13
相关论文
共 50 条
  • [41] Non-contact measurement of aspherical and freeform optics with a new confocal tracking profiler
    Pinto, Agusti
    Laguarta, Ferran
    Artigas, Roger
    Cadevall, Cristina
    OPTICAL FABRICATION, TESTING, AND METROLOGY IV, 2011, 8169
  • [42] Non-Contact Body Measurement for Qinchuan Cattle with LiDAR Sensor
    Huang, Lvwen
    Li, Shuqin
    Zhu, Anqi
    Fan, Xinyun
    Zhang, Chenyang
    Wang, Hongyan
    SENSORS, 2018, 18 (09)
  • [43] Sleep/wake measurement using a non-contact biomotion sensor
    de Chazal, Philip
    Fox, Niall
    O'Hare, Emer
    Heneghan, Conor
    Zaffaroni, Alberto
    Boyle, Patricia
    Smith, Stephanie
    O'Connell, Caroline
    McNicholas, Walter T.
    JOURNAL OF SLEEP RESEARCH, 2011, 20 (02) : 356 - 366
  • [44] Tribological measurement of the state of surface fabrics by a contact and a non-contact methods
    Bueno, MA
    Renner, M
    Durand, B
    MECHATRONICS '98, 1998, : 703 - 708
  • [45] Non-contact Surface Roughness Measurement Based on Laser Technology and Neural Network
    Xu, Xiaomei
    2009 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, VOLS 1-7, CONFERENCE PROCEEDINGS, 2009, : 4474 - 4478
  • [46] Non-contact measurement of contact wire
    Yi Yaxing
    Ye Xuemei
    Li Zhongke
    Yue Kaiduan
    2008 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTOELECTRONIC MEASUREMENT TECHNOLOGY AND APPLICATIONS, 2009, 7160
  • [47] Applications of non-contact deformation measurement in mechanical properties study of MEMS
    Kang, X
    He, XY
    Liu, L
    THIRD INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, 2002, 4537 : 418 - 421
  • [48] Non-Contact Measurement of Residual Magnetization Caused by Plastic Deformation of Steel
    Saleem, Aroba
    Underhill, P. Ross
    Krause, Thomas W.
    JOURNAL OF NONDESTRUCTIVE EVALUATION, DIAGNOSTICS AND PROGNOSTICS OF ENGINEERING SYSTEMS, 2020, 3 (03):
  • [49] Non-contact measurement of thermal conduction by infrared radiation calorimetry
    Hisano, K