Applications of non-contact deformation measurement in mechanical properties study of MEMS

被引:0
|
作者
Kang, X [1 ]
He, XY [1 ]
Liu, L [1 ]
机构
[1] Southeast Univ, Dept Engn Mech, Nanjing 210096, Peoples R China
关键词
material properties; MEMS; sub-pixel; tensile strain;
D O I
10.1117/12.468759
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The reliability and lifetime of microelectromechanical systems (MEMS) are strongly depending on the material properties. It is important to develop methods for the measurement of MEMS material proper-ties. In this paper an optical technique for measuring tensile strain of micro-specimen is proposed. The technique, which based on digital speckle correlation method (DSCM), works by determining the deformation of specimen between two neighboring loading step by step. The problem of non-correlation is solved when the deformation is too large. The experimental results of a copper wire (diameter 0.1mm) are given in this paper. The proposed technique is also applicable for measuring other MEMS materials that may be even smaller or thinner than that used in this paper.
引用
收藏
页码:418 / 421
页数:4
相关论文
共 50 条
  • [1] Non-contact measurement of local grammage and mechanical material properties
    Swedish Pulp and Paper Research Inst, Stockholm, Sweden
    Meas Sci Technol, 8 (921-926):
  • [2] Non-contact measurement of local grammage and mechanical material properties
    Anttila, J
    Pettersson, T
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1997, 8 (08) : 921 - 926
  • [3] Non-contact temperature measurement in embedded applications
    Ibrahim, Dogan
    ELECTRONICS WORLD, 2017, 123 (1971): : 14 - 16
  • [4] Non-contact methods for thermal properties measurement
    Abad, B.
    Borca-Tasciuc, D. -A.
    Martin-Gonzalez, M. S.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 76 : 1348 - 1370
  • [5] Online measurement of cornea deformation during non-contact tonometry
    Krijger, Tim
    Kaneko, Makoto
    2011 IEEE SENSORS, 2011, : 1913 - 1916
  • [6] Modern optoelectronic methods for non-contact deformation measurement in industry
    Novak, J
    Miks, A
    JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2002, 4 (06): : S413 - S420
  • [7] Non-contact characterization of MEMS dynamics
    Dräbenstedt, A
    Heimes, F
    Hettwer, D
    Rembe, C
    Steger, H
    Wörtge, M
    TM-TECHNISCHES MESSEN, 2005, 72 (11) : 601 - 608
  • [8] Study on Non-contact Measurement of Respiratory Rate
    Sogabe Y.
    Sano M.
    Transactions of Japanese Society for Medical and Biological Engineering, 2020, 58 : 592 - 593
  • [9] Mechanical properties of PVC geomembrane under uniaxial tension based on non-contact measurement
    Zhang, X. L.
    Wu, Y. Y.
    Ma, Z. Y.
    Yin, C. J.
    GEOSYNTHETICS INTERNATIONAL, 2023, 30 (03) : 259 - 273
  • [10] Non-contact measurement of the mechanical properties of materials using an all-optical technique
    Culshaw, B