Measurements and Analysis of Sound Reflections from Selected Building Façades

被引:0
|
作者
Zagubien, Adam [1 ]
Wolniewicz, Katarzyna [1 ]
机构
[1] Koszalin Univ Technol, Fac Civil Engn Environm & Geodet Sci, Ul Sniadeckich 2, PL-75453 Koszalin, Poland
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 24期
关键词
microphone location; environmental noise; noise pollution; noise monitoring; ROAD TRAFFIC NOISE; ENVIRONMENTAL NOISE; FIELDS; SLEEP;
D O I
10.3390/app142411627
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This paper presents a study of the effect of the type of exterior cladding material of a building fa & ccedil;ade on the amount of sound reflection. It was verified whether there is a sound field undisturbed by reflections, similar to the free field, at a distance of 3 m from the building fa & ccedil;ade. Sound reflections from three building fa & ccedil;ade structures were tested: clinker brick, mineral plaster, and hard HPL. An equal geometry of the measuring field at selected real objects was used. It was determined that the differences in sound level results measured at distances up to 2 m and more than 2 m from the building fa & ccedil;ade are lower than the -3 dB correction specified in ISO 1996-2. Significant differences were observed comparing the measured sound level values in the undisturbed sound field with the levels recorded at a distance of 3 m from the building fa & ccedil;ade. It was proposed that the results of measurements made to control the levels of permissible noise in the environment should not be subject to the -3 dB correction.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Comparative analysis of service life prediction methods applied to rendered fa‡ades
    Silva, Ana
    de Brito, Jorge
    Gaspar, Pedro L.
    MATERIALS AND STRUCTURES, 2016, 49 (11) : 4893 - 4910
  • [42] Calculation Method and Analysis for the Annual Power Generation of PV Faades in China
    Shen Xu
    ZhongMing Hu
    Jian Kang
    Wei Liao
    Jing Huang
    Journal of Harbin Institute of Technology, 2014, 21 (04) : 62 - 68
  • [43] APC2Mesh: Bridging the gap from occluded building façades to full 3D models
    Hope Akwensi P.
    Bharadwaj A.
    Wang R.
    ISPRS Journal of Photogrammetry and Remote Sensing, 2024, 211 : 438 - 451
  • [44] Comprehensive and enhanced characterisation of wind-driven rain exposure on building façades throughout the Netherlands
    Perez-Bella, Jose M.
    Dominguez-Hernandez, Javier
    Orna-Carmona, Martin
    Lopez-Julian, Pedro L.
    Ibarz-Montaner, Elena
    BUILDING AND ENVIRONMENT, 2025, 271
  • [45] Development and verification of an airflow-type photovoltaic-integrated shading device on building façades
    Lee, Sihwan
    Ito, Risa
    APPLIED ENERGY, 2025, 383
  • [46] Comparative analysis of service life prediction methods applied to rendered façades
    Ana Silva
    Jorge de Brito
    Pedro L. Gaspar
    Materials and Structures, 2016, 49 : 4893 - 4910
  • [47] Calculation Method and Analysis for the Annual Power Generation of PV Faades in China
    Shen Xu
    Zhong-Ming Hu
    Jian Kang
    Wei Liao
    Jing Huang
    Journal of Harbin Institute of Technology(New series), 2014, (04) : 62 - 68
  • [48] Drone-assisted segmentation of tile peeling on building façades using a deep learning model
    Cao, Minh-Tu
    JOURNAL OF BUILDING ENGINEERING, 2023, 80
  • [49] Building Impulse Toolkit (BIT): A novel IoT system for capturing the influence of fa?ades on occupant perception and occupant-fa?ade interaction
    Luna-Navarro, Alessandra
    Fidler, Paul
    Law, Alistair
    Torres, Santiago
    Overend, Mauro
    BUILDING AND ENVIRONMENT, 2021, 193
  • [50] Detecting and inferring repetitive elements with accurate locations and shapes from façades
    Yongjian Lian
    Xukun Shen
    Yong Hu
    The Visual Computer, 2018, 34 : 491 - 506