摘要
This paper presents a study of the effect of the type of exterior cladding material of a building fa & ccedil;ade on the amount of sound reflection. It was verified whether there is a sound field undisturbed by reflections, similar to the free field, at a distance of 3 m from the building fa & ccedil;ade. Sound reflections from three building fa & ccedil;ade structures were tested: clinker brick, mineral plaster, and hard HPL. An equal geometry of the measuring field at selected real objects was used. It was determined that the differences in sound level results measured at distances up to 2 m and more than 2 m from the building fa & ccedil;ade are lower than the -3 dB correction specified in ISO 1996-2. Significant differences were observed comparing the measured sound level values in the undisturbed sound field with the levels recorded at a distance of 3 m from the building fa & ccedil;ade. It was proposed that the results of measurements made to control the levels of permissible noise in the environment should not be subject to the -3 dB correction.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Integrated façades: How technology development and building codes are shaping the future
    Technical Business Development, SAGE Electrochromics Inc., Cambridge University, United Kingdom
    不详
    Energy Eng, 2 (42-56):
  • [22] The Integration of Bio-Active Elements into Building Façades as a Sustainable Concept
    Metwally, Walaa Mohamed
    Ibrahim, Vitta Abdel Rehim
    BUILDINGS, 2024, 14 (10)
  • [23] The effect of optical anisotropies on building glass fa?ades and its measurement methods
    MIllguth
    CSchuler
    Bucak
    Frontiers of Architectural Research, 2015, 4 (02) : 119 - 126
  • [24] Improving residential building efficiency with membranes over fa ades: The Mediterranean context
    Corticos, Nuno D.
    JOURNAL OF BUILDING ENGINEERING, 2020, 32
  • [25] A Visual Preference Analysis of Building Façades in Street View Images: A Case Study of Nanshan District, Shenzhen
    Lee, Chia-Chen
    Wang, Yuxiao
    Tang, Chenggao
    Li, Xiang
    Yin, Jie
    BUILDINGS, 2025, 15 (04)
  • [26] Segmentation of building fa ades from vehicle-borne laser scanning data based on mathematical morphology
    Shen Yonglin
    Sheng Yehua
    SIXTH INTERNATIONAL SYMPOSIUM ON DIGITAL EARTH: DATA PROCESSING AND APPLICATIONS, 2010, 7841
  • [27] Optimal control of switchable ethylene-tetrafluoroethylene (ETFE) cushions for building fa?ades
    Faramarzi, Afshin
    Stephens, Brent
    Heidarinejad, Mohammad
    SOLAR ENERGY, 2021, 218 : 180 - 194
  • [28] Waste Paint as Admixture for Glass Fiber-Reinforced Concrete Building Façades
    Fernando, Dushan
    Rajeev, Pathmanathan
    Ramesh, Akilesh
    Sanjayan, Jay
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2024, 36 (10)
  • [29] What is Guarded Airtightness Testing, and How Does it Benefit Tall Building Façades
    Moore, Jesse
    CTBUH Journal, 2019, 2019 (04)
  • [30] Comprehensive impact of two advanced thermotropic façades designs on building daylight and energy performance
    Ming, Yang
    Jiang, Fujian
    Alkan, Cemil
    Yuan, Yanping
    Wu, Yupeng
    ENERGY AND BUILDINGS, 2025, 334