Dynamic Modeling and Analysis of the Main Steam Relief Isolation Valve (MSRIV) Used in Nuclear Power Plants

被引:0
|
作者
Zong, Chaoyong [1 ,2 ]
Li, Qingye [2 ]
Peng, Yue [3 ]
Yang, Guanghong [3 ]
Zhou, Weihao [2 ]
Xiao, Jian [4 ]
Song, Xueguan [2 ]
机构
[1] College of Mechanical and Electrical Engineering, Harbin Engineering University, Harbin,150001, China
[2] School of Mechanical Engineering, Dalian University of Technology, Dalian,116024, China
[3] China Nuclear Power Engineering Co., Ltd., Shenzhen,518124, China
[4] Dalian DV Valve Co., Ltd., Dalian,116037, China
关键词
Aerodynamics - Nuclear energy - Safety valves - Secondary flow - Steam power plants - Transient analysis;
D O I
10.3901/JME.2024.20.339
中图分类号
学科分类号
摘要
Nuclear main steam relief isolation valve(MSRIV) is one type of high-end control valve, which plays an important role in ensuring the safety and function of the secondary circuit system of nuclear power plants. To reveal its operation mechanism in depth, this paper starts from fluid-structure-thermal multi-physics coupling modeling, combined with prototype experiments, and conducts a special study on the flow fields, action characteristics and key design parameters of the MSRIV. The generation and evolution mechanism of the internal flow field and the change mechanism of the driving force under the multi-field coupling are revealed, thereby the influence of key design parameters on the valve action performance is explored. The research methods and conclusions of this paper are not only helpful to the in-depth understanding of the operating characteristics of the MSRIV, but also have reference value for its design and performance improvement, and also the going out strategy of China. © 2024 Chinese Mechanical Engineering Society. All rights reserved.
引用
收藏
页码:339 / 350
相关论文
共 50 条
  • [31] MATHEMATICAL-MODELING OF A SPRINKLER SYSTEM TO BE USED IN NUCLEAR-POWER-PLANTS
    GALL, U
    KERNENERGIE, 1987, 30 (09): : 358 - 363
  • [32] Steam generators – horizontal or vertical (which type should be used in nuclear power plants with VVER?)
    N. B. Trunov
    B. I. Lukasevich
    D. O. Veselov
    Yu. G. Dragunov
    Atomic Energy, 2008, 105 : 165 - 174
  • [33] Availability analysis of heat recovery steam generators used in thermal power plants
    Carazas, F. J. G.
    Salazar, C. H.
    Souza, G. F. M.
    ENERGY, 2011, 36 (06) : 3855 - 3870
  • [34] Dynamic modeling and characteristic analysis of the double-reactor and quadruple-turbine nuclear power system based on steam main-pipeline distribution characteristics
    Cui, Chengcheng
    Shen, Jiong
    Zhang, Junli
    ANNALS OF NUCLEAR ENERGY, 2022, 170
  • [35] Evaluation of LBB characteristics of candidate materials for main steam line piping in Korea nuclear power plants
    Hong, Seokmin
    Kim, Jongmin
    Kim, Maan-Won
    Kim, Hong-Deok
    Lee, Bong-Sang
    Kim, Min-Chul
    INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 2020, 188
  • [36] Analysis and Comparison of Main Steam Turbines from Four Different Thermal Power Plants
    Mrzljak, Vedran
    Jelic, Maro
    Poljak, Igor
    Prpic-Orsic, Jasna
    POMORSTVO-SCIENTIFIC JOURNAL OF MARITIME RESEARCH, 2023, 37 (01) : 58 - 74
  • [37] Thermal Analysis and Statistical Evaluation of EPR Used in Nuclear Power Plants
    Kim, Ji Yean
    Park, Dae Hee
    2015 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2015, : 5 - 8
  • [38] Strength Analysis of Vertical Flow Steam Generators of Nuclear Power Plants.
    Niezgodzinski, Michal
    Zwolinski, Waclaw
    Mechanika Teoretyczna i Stosowana, 1981, 19 (02): : 217 - 224
  • [39] Oconee nuclear power station main steam line break analysis for steam generator tube stress evaluation
    Muransky, JS
    Shatford, JG
    Peterson, CE
    Swindlehurst, GB
    NUCLEAR TECHNOLOGY, 2004, 148 (01) : 48 - 55
  • [40] Analysis for Abnormal Shaft Vibration of Main Coolant Pump in Nuclear Power Plants
    Li Z.
    Yuan S.
    Hedongli Gongcheng/Nuclear Power Engineering, 2019, 40 (01): : 167 - 171