Characteristics of Sterilised Nickel Titanium and Stainless Steel Orthodontic Archwires

被引:0
|
作者
Abood, Akhlas Zeid [1 ,2 ]
Noor, Siti Noor Fazliah Mohd [2 ,3 ]
Suhaimi, Fatanah Mohamad [2 ,3 ]
Al-Fatlawi, Fakhri Abid Ali Hussein [4 ]
Shafiai, Noor Ayuni Ahmad [2 ]
机构
[1] Middle Tech Univ, Coll Hlth & Med Tech, Dept Prosthet Dent Tech, Baghdad 10074, Iraq
[2] Univ Sains Malaysia, Adv Med & Dent Inst, Dept Dent Sci, Kepala Batas 13200, Pulau Pinang, Malaysia
[3] Univ Sains Malaysia, Adv Med & Dent Inst, Dent Stimulat & Virtual Learning, Res Excellence Consortium, Kepala Batas 13200, Pulau Pinang, Malaysia
[4] Al Farabi Collect Coll, Baghdad 11691, Iraq
关键词
sterilisation method; super elastic NiTi; stainless steel wire; archwire; surface morphology; MECHANICAL-PROPERTIES; SURFACE-ROUGHNESS; WIRES;
D O I
10.21315/jps2024.35.3.3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Sterilisation removes microorganisms in the vegetative or spore states from a material, surface or medium. Ensuring infection control is of utmost importance for health safety. Pathogenic microorganisms are frequently transmitted from one person to another because of ineffective sterilising agents, apparatus and equipment. The aim of this study is to investigate the effect of sterilisation methods on morphological parameters of super elastic nickel titanium (NiTi) and stainless steel (SS) orthodontic archwires. The archwires were sterilised using a variety of methods, including dry heat sterilisation (oven) at 160 degrees C for 1 h, steam heat sterilisation (autoclave) at 121 degrees C for 15 min and cold sterilisation (2% glutaraldehyde) at 10 h. After sterilisation, the wires were tested, and the morphological changes was determined through atomic force microscopy (AFM), scanning electron microscopy (SEM) and X-ray diffraction (XRD). The AFM and SEM results obtained before and after the sterilisation of the NiTi and SS orthodontic archwires did not show clear differences in the surface structure. No changes in the elemental composition of the NiTi and SS wires, and no new phase appeared according to the XRD results which support the use of archwire sterilisation procedures as part of the infection control treatment and are considered a suitable procedure related to the characterisation of the orthodontic archwires.
引用
收藏
页码:27 / 48
页数:22
相关论文
共 50 条
  • [21] FUNCTIONAL PROPERTIES OF SUPERELASTIC ORTHODONTIC NICKEL-TITANIUM ARCHWIRES WITH PROTECTIVE TITANIUM NITRIDE COATINGS
    Rubanik, Vasili V.
    Rubanik, Vasili V., Jr.
    Bahrets, Dzmitry A.
    Dorodeiko, Viachaslau G.
    DOKLADY NATSIONALNOI AKADEMII NAUK BELARUSI, 2019, 63 (05): : 608 - 619
  • [22] Orthodontic stainless steel wire and nickel release
    Castro, S.
    Ponces, M. J.
    Lopes, J. D.
    Vasconcelos, M.
    Reis Campos, J. C.
    Pollmann, C.
    BIODENTAL ENGINEERING V, 2019, : 113 - 114
  • [23] Effect of titanium nitride/titanium coatings on the stress corrosion of nickel-titanium orthodontic archwires in artificial saliva
    Liu, Jia-Kuang
    Liu, I-Hua
    Liu, Cheng
    Chang, Chen-Jung
    Kung, Kuan-Chen
    Liu, Yen-Ting
    Lee, Tzer-Min
    Jou, Jin-Long
    APPLIED SURFACE SCIENCE, 2014, 317 : 974 - 981
  • [24] A randomized clinical trial investigating pain associated with superelastic nickel-titanium and multistranded stainless steel archwires during the initial leveling and aligning phase of orthodontic treatment
    Sandhu, Satpal Singh
    Sandhu, Jasleen
    JOURNAL OF ORTHODONTICS, 2013, 40 (04) : 276 - 285
  • [25] NICKEL-TITANIUM (NI-TI) ALLOYS FROM THE COMPOSITION OF ORTHODONTIC ARCHWIRES
    Teodorescu, Elina
    Galan, Elena
    Milicescu, Stefan, Jr.
    Pascu, Raluca
    Ionescu, Ileana
    Ionescu, Ecaterina
    METALURGIA INTERNATIONAL, 2010, 15 : 19 - 23
  • [26] EFFECTS OF THERMOCYCLING AND PH ON ULTRASTRUCTURES CHARACTERISTICS OF STAINLESS STEEL ARCHWIRES
    Sheibaninia, Ahmad
    Ojani, Zahra
    Zarrabi, Fatemeh
    Rabbani, Marzeih
    Heydari, Niloufar
    JP JOURNAL OF BIOSTATISTICS, 2019, 16 (02) : 139 - 149
  • [27] Comparison of the superelasticity of different nickel–titanium orthodontic archwires and the loss of their properties by heat treatment
    Humberto Bellini
    Javier Moyano
    Javier Gil
    Andreu Puigdollers
    Journal of Materials Science: Materials in Medicine, 2016, 27
  • [28] Characterization and cytotoxicity of ions released from stainless steel and nickel-titanium orthodontic alloys
    Eliades, T
    Pratsinis, H
    Kletsas, D
    Eliades, G
    Makou, M
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2004, 125 (01) : 24 - 29
  • [29] A comparison of stainless steel and nickel titanium coils in the rat model of orthodontic tooth movement.
    Loveless, J
    Theroux, K
    Vayda, P
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 253 - 253
  • [30] Efficacy of zirconium oxide nanoparticles coated on stainless steel and nickel titanium wires in orthodontic treatment
    Selvaraj, Abirami
    George, Ashwin Mathew
    Rajeshkumar, S.
    BIOINFORMATION, 2021, 17 (08) : 760 - 766