EFFECTS OF THERMOCYCLING AND PH ON ULTRASTRUCTURES CHARACTERISTICS OF STAINLESS STEEL ARCHWIRES

被引:0
|
作者
Sheibaninia, Ahmad [1 ]
Ojani, Zahra [1 ]
Zarrabi, Fatemeh [1 ]
Rabbani, Marzeih [1 ]
Heydari, Niloufar [1 ]
机构
[1] Islamic Azad Univ, Dept Orthodont, Dent Sch, Tehran Branch, Tehran, Iran
关键词
surface roughness; stiffness; saliva PH; thermocycling; stainless steel wire; ORTHODONTIC ARCH WIRES; MECHANICAL-PROPERTIES; NICKEL RELEASE; BETA-TITANIUM; ION RELEASE; FLUORIDE;
D O I
10.17654/BS016020139
中图分类号
O21 [概率论与数理统计]; C8 [统计学];
学科分类号
020208 ; 070103 ; 0714 ;
摘要
Aim and Background. There are certain controversies about different changes in surface roughness and stiffness of stainless steel (SS) wires; also, the effects of thermocycling and saliva PH on the surface and mechanical properties of these orthodontics archwires. In the present study, the effects of thermocycling and saliva PH on the surface and mechanical properties of SS wires in Metallurgical Laboratory of Shiraz University during 2016-2017 were investigated. Method and materials. 5cm pieces of 0.016inch SS wires from Ormco Company were placed in a glassed-tube enclosed by borosilicate. The wires were randomly divided into groups 1, deepening in artificial saliva (PH 7.4), consisted of subgroups 1 and 2 and the second group with wires placed in the ascorbic acid contained artificial saliva (PH 4.5) consisted of subgroups 3 and 4 and each subgroup contained 10 pieces. 500 cycles of thermocycling in the 5 to 55 degrees C water were only applied to the subgroups 2 and 4. Surface and mechanical properties of SS wires were evaluated by Instron (Tensile Machine, Finland) and its roughness was measured by AFM machine. Finally, the data was analyzed using ANOVA. Results. A total of 40 samples in four groups based on different PH and presence/absence of thermocycling were evaluated. The most surface roughness was 0.15 +/- 0.02 mu m/Ra in PH 4.5 and presence of thermocycling. The lowest surface roughness was 0.06 +/- 0.009 mu m/Ra in PH 7.4 without thermocycling (P < 0.001). The maximum amount of stiffness was 24.6 +/- 1.4g/mm(2) in PH 7.4 without thermocycling and the lowest amount of it was 012.5 +/- 0.9g/mm(2) in PH 4.5 with the presence of thermocycling (P < 0.001). Conclusion. It seems that the lowest effects on the surface and mechanical properties of SS wires were induced in PH 7.4 without thermocycling.
引用
收藏
页码:139 / 149
页数:11
相关论文
共 50 条
  • [1] Characteristics of Sterilised Nickel Titanium and Stainless Steel Orthodontic Archwires
    Abood, Akhlas Zeid
    Noor, Siti Noor Fazliah Mohd
    Suhaimi, Fatanah Mohamad
    Al-Fatlawi, Fakhri Abid Ali Hussein
    Shafiai, Noor Ayuni Ahmad
    JOURNAL OF PHYSICAL SCIENCE, 2024, 35 (03) : 27 - 48
  • [2] Thermal and mechanical characteristics of stainless steel, titanium-molybdenum, and nickel-titanium archwires
    Kusy, Robert P.
    Whitley, John Q.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (02) : 229 - 237
  • [3] Stainless steel and NiTi torque archwires and apical root resorption
    Wichelhaus, Andrea
    Dulla, Marc
    Sabbagh, Hisham
    Baumert, Uwe
    Stocker, Thomas
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2021, 82 (01): : 1 - 12
  • [4] Synergistic effect of wire bending and salivary pH on surface properties and mechanical properties of orthodontic stainless steel archwires
    Hobbelink, Marieke G.
    He, Yan
    Xu, Jia
    Xie, Huixu
    Stoll, Richard
    Ye, Qingsong
    PROGRESS IN ORTHODONTICS, 2015, 16
  • [5] Synergistic effect of wire bending and salivary pH on surface properties and mechanical properties of orthodontic stainless steel archwires
    Marieke G. Hobbelink
    Yan He
    Jia Xu
    Huixu Xie
    Richard Stoll
    Qingsong Ye
    Progress in Orthodontics, 16
  • [6] Frictional characteristics of composite orthodontic archwires against stainless steel and ceramic brackets in the passive and active configurations
    Zufall, SW
    Kennedy, KC
    Kusy, RP
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1998, 9 (11) : 611 - 620
  • [7] Frictional characteristics of composite orthodontic archwires against stainless steel and ceramic brackets in the passive and active configurations
    S. W. Zufall
    K. C. Kennedy
    R. P. Kusy
    Journal of Materials Science: Materials in Medicine, 1998, 9 : 611 - 620
  • [8] Morphological characterization of as-received and in vivo orthodontic stainless steel archwires
    Daems, Julie
    Celis, Jean-Pierre
    Willems, Guy
    EUROPEAN JOURNAL OF ORTHODONTICS, 2009, 31 (03) : 260 - 265
  • [9] Debris, Roughness and Friction of Stainless Steel Archwires Following Clinical Use
    Vieira Marques, Isabella Silva
    Araujo, Adriana M.
    Gurgel, Julio A.
    Normando, David
    ANGLE ORTHODONTIST, 2010, 80 (03) : 521 - 527
  • [10] Transverse adjustment of preformed stainless steel archwires to the dental arch form
    Koda, Takashi
    Saze, Naomi
    Tochigi, Keisuke
    Arai, Kazuhito
    ORTHODONTIC WAVES, 2018, 77 (02) : 142 - 149