Cable-stayed bridge concept for longer spans

被引:5
|
作者
DSD Dillinger Stahlbau GmbH, Saarlouis, Germany [1 ]
机构
来源
Journal of Bridge Engineering | 1996年 / 1卷 / 03期
关键词
Costs - Dynamic loads - Structural analysis - Struts - Suspension bridges;
D O I
暂无
中图分类号
学科分类号
摘要
Achieving larger maximum spans by inventing new bridge systems has always been a fascinating intellectual challenge. Several concepts of modified cable-supported bridges have been proposed in the past that promise to surpass the more traditional cable-supported bridges in terms of maximum span length. Some of these concepts are recalled in this paper. An alternative concept derived from the classical cable-stayed bridge system is presented. Instead of vertical pylons, pairs of inclined pylon legs, spreading out longitudinally and connected at the top by horizontal ties, are used. The merits and shortcomings of such a system are discussed. Based on a comparative analysis of forces, quantities, and costs, it is concluded that the alternative concept presented in this paper not only allows the achievement of larger maximum spans, but also can lead to an economically advantageous design - even within the span-length range of the classical cable-stayed bridge system.
引用
收藏
页码:99 / 103
相关论文
共 50 条
  • [31] Primary exploration for concept and studying method of cable-beam vibration in a cable-stayed bridge
    Wang, Tao
    Shen, Rui-Li
    Li, Hong
    Zhendong yu Chongji/Journal of Vibration and Shock, 2013, 32 (20): : 29 - 34
  • [32] Thermal Effect of the Cable-Stayed Bridge Tower
    Zhang Hai-long
    Wuhan University Journal of Natural Sciences, 2003, (04) : 1121 - 1125
  • [33] On the design and construction of Maysville Cable-Stayed Bridge
    Tang, FF
    Hansen, JM
    15TH ANNUAL INTERNATIONAL BRIDGE CONFERENCE AND EXHIBITION, 1998, : 117 - 121
  • [34] Dynamic tests of the Santarem cable-stayed bridge
    Rodrigues, J
    PROCEEDINGS OF IMAC-XIX: A CONFERENCE ON STRUCTURAL DYNAMICS, VOLS 1 AND 2, 2001, 4359 : 1146 - 1152
  • [35] On the design and construction of Maysville Cable-Stayed Bridge
    Tang, FF
    Hansen, JM
    15TH ANNUAL INTERNATIONAL BRIDGE CONFERENCE AND EXHIBITION, PROCEEDINGS, 1998, : 117 - 121
  • [36] MODAL IDENTIFICATION OF CABLE-STAYED PEDESTRIAN BRIDGE
    GARDNERMORSE, MG
    HUSTON, DR
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1993, 119 (11): : 3384 - 3404
  • [37] Rehabilitation of Yeongheung cable-stayed bridge in Korea
    Vonk, Edo
    Shim, Byul
    fib Symposium, 2020, : 2187 - 2194
  • [38] Research on Structure design of Cable-stayed Bridge
    Li, Xi
    Cai, Tingting
    SUSTAINABLE ENVIRONMENT AND TRANSPORTATION, PTS 1-4, 2012, 178-181 : 2565 - 2569
  • [39] Initial thoughts on the design of a cable-stayed bridge
    Hunt, I
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 1997, 122 (02) : 218 - 226
  • [40] Second Severn crossing - cable-stayed bridge
    Mizon, DH
    Smith, N
    Yeoward, AJ
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-CIVIL ENGINEERING, 1997, 120 : 49 - 63