SELECTION OF TARGET VOLTAGE UHV AC TRANSMISSION.

被引:0
|
作者
Yamada, Naohei
机构
来源
Energy developments in Japan | 1983年 / 6卷 / 01期
关键词
ELECTRIC POWER SYSTEMS - Japan;
D O I
暂无
中图分类号
学科分类号
摘要
To cope with the changing demands of power transmission, the UHV Transmission Development and Promotion Committee was created in 1973 within the Central Electric Power Council (consisting of the nine Japanese electric power companies and the Electric Power Development Company). The Committee targeted the selection of the voltage rating for the UHV ac transmission system (hereinafter referred to as the target voltages) as the first important problem to be considered. The Committee carried out extensive surveys and research, and after full deliberation, taking into account the actual conditions of Japan, it reached the conclusion that it would be appropriate to select a nominal voltage of 1,000 kv and the corresponding highest voltage of 1,100 kv as the target voltages. It reported its conclusion to the Central Electric Power Council in a session held in June of 1980. This paper presents the background of the target voltage selection of the Committee.
引用
收藏
页码:21 / 30
相关论文
共 50 条
  • [31] Harmonic analysis of fault signal in UHV AC transmission line
    Suonan, Jia-Le
    Wang, Li
    Xia, Jing-De
    He, Shi-En
    Gaodianya Jishu/High Voltage Engineering, 2010, 36 (01): : 37 - 43
  • [32] Study for voltage regulation and reactive power compensation for UHV AC transmission with IEEE P1860 draft standard
    Ma, Shicong
    Guo, Jianbo
    Ma, Shiying
    Yi, Jun
    Zhang, Jian
    Sun, Huadong
    2014 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2014,
  • [33] Numerical model of lightning attachment on UHV-AC transmission lines and effects of operating voltage, phase angle, and terrain
    Ma, Ziwei
    Jasni, Jasronita
    Ab Kadir, Mohd Zainal Abidin
    Azis, Norhafiz
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 227
  • [34] AC WITHSTAND VOLTAGE CHARACTERISTICS OF CONTAMINATED INSULATORS FOR UHV IN STEAM FOG
    ARAI, N
    SETA, T
    KARADY, G
    BEAUSEJOUR, Y
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1980, 99 (04): : 1320 - 1320
  • [35] Reactive power and voltage optimization of UHV AC synchronized power grid
    Jiang, Ping
    Qin, Yu
    Gu, Wei
    Ding, Yang
    Sun, Gang
    Dianli Zidonghua Shebei / Electric Power Automation Equipment, 2009, 29 (08): : 95 - 99
  • [36] The Laval transmission.
    Karlin, HB
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1924, 68 : 327 - 329
  • [37] Energy transmission.
    不详
    NATURE, 1919, 103 : 93 - 93
  • [38] AUDIO TRANSMISSION.
    Lonergan, J.L.
    Post Office Electrical Engineers Journal, 1981, 74 (pt 3): : 263 - 264
  • [39] Lost in transmission. . .?
    Lello, Joanne
    Fenton, Andy
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 2017, 372 (1719)
  • [40] Analysis of Ion Flow Field of UHV/EHV AC Transmission Lines
    Zhang, Bo
    Li, Wei
    He, Jinliang
    Zeng, Rong
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (02) : 496 - 504