Monte Carlo investigation of the charge sharing effects in 3-D position sensitive CdZnTe gamma ray spectrometers

被引:0
|
作者
Du, Y.F. [1 ]
He, Z. [1 ]
Li, W. [1 ]
Knoll, G.F. [1 ]
Wehe, D.K. [1 ]
机构
[1] Univ of Michigan, Ann Arbor, United States
关键词
Anodes - Carrier mobility - Computer simulation - Electron traps - Electrons - Monte Carlo methods - Semiconducting cadmium compounds - X rays;
D O I
暂无
中图分类号
学科分类号
摘要
Charge sharing effects in a 3-D position sensitive CdZnTe detector have been investigated by Monte Carlo simulations and experimental measurements. The charge sharing is mainly caused by the range of electrons, x-ray emission following by photoelectric interactions, and the diffusion of charge carrier electrons during their drift towards the anodes. A simple model has been developed to include the diffusion effect in the Monte Carlo simulation. Good agreement has been achieved for various irradiation and bias conditions. Based on our model simulations, a 1 mm optimal pixel size is recommended for future 1 cm thick CZT detectors for 662 keV gamma rays.
引用
收藏
页码:634 / 637
相关论文
共 50 条
  • [41] 3-D position sensitive CdZnTe spectrometer performance using third generation VAS/TAT readout electronics
    Zhang, F
    He, Z
    Knoll, GF
    Wehe, DK
    Berry, JE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 2009 - 2016
  • [42] A 3-D Lagrangian (Monte carlo) method for direct plume gamma dose rate calculations
    Raza, SS
    Avila, R
    Cervantes, J
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2001, 38 (04) : 254 - 260
  • [43] Characterization of the H3D ASIC Readout System and 6.0 cm3 3-D Position Sensitive CdZnTe Detectors
    Zhang, Feng
    Herman, Cedric
    He, Zhong
    De Geronimo, Gianluigi
    Vernon, Emerson
    Fried, Jack
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (01) : 236 - 242
  • [44] Sub-Pixel Position Sensing for Pixelated, 3-D Position Sensitive, Wide Band-Gap, Semiconductor, Gamma-Ray Detectors
    Zhu, Yuefeng
    Anderson, Stephen E.
    He, Zhong
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (03) : 1400 - 1409
  • [45] Investigation of accelerated monte carlo techniques for PET simulation and 3-D PET scatter correction
    Holdsworth, CH
    Levin, CS
    Farquhar, TH
    Dahlbom, M
    Hoffman, EJ
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1500 - 1504
  • [46] Dose prediction and process optimization in a gamma sterilization facility using 3-D Monte Carlo code
    Weiss, DE
    Stangeland, RJ
    RADIATION PHYSICS AND CHEMISTRY, 2003, 68 (06) : 947 - 958
  • [47] Monte Carlo simulation of charge sharing effects in silicon and GaAs photon counting X-ray imaging detectors
    Nilsson, HE
    Fröjdh, C
    Dubaric, E
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1401 - 1404
  • [48] 1-D Fast Neutron Source Localization Using Digital Pixelated 3-D Position-Sensitive CdZnTe Detectors
    Goodman, David
    Streicher, Michael
    Zhu, Yuefeng
    Brown, Steven
    He, Zhong
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2017, 64 (09) : 2531 - 2535
  • [49] Collimator-less 4π Gamma Imaging with 3-D Position-sensitive Detector
    Ye, Qing
    Fan, Peng
    Wei, Qingyang
    Yu, Yunhan
    Wang, Shi
    Liu, Yaqiang
    Ma, Tianyu
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [50] High Resolution Time-Encoded Imaging of Plutonium and MOX using 3-D Position-Sensitive CdZnTe Detectors
    Goodman, David
    Xia, Jiawei
    Brown, Steven
    Chichester, David L.
    He, Zhong
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,