Collimator-less 4π Gamma Imaging with 3-D Position-sensitive Detector

被引:0
|
作者
Ye, Qing [1 ]
Fan, Peng [3 ]
Wei, Qingyang [4 ]
Yu, Yunhan [3 ]
Wang, Shi [3 ]
Liu, Yaqiang [3 ]
Ma, Tianyu [2 ]
机构
[1] Tsinghua Univ, Minist Educ, Key Lab Particle & Radiat Imaging, Dept Engn Phys,Med Phys Lab, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[3] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[4] Univ Sci Technol, Sch Automat & Elect Engn, Dept Instrument Sci, Beijing 100083, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Fast and accurate lost radioactive source positioning is of critical importance for the prevention of radiation damage in the accident. Traditional instruments with low detection efficiency cost lots pf time and energy, and may lead to harms to the operator's health. A portable detector to directly determine the incident angle of gamma rays is promising for the homeland security applications. In this work, we proposed a collimator-less 4 pi gamma imaging with 3-D position-sensitive detector. The distribution of photon counts is dependent on the orientation angle of the point gamma source, and the angle is reconstructed with Maximum Likelihood Expectation Maximization (MLEM) algorithm. Angular resolution of this imaging system was calculated by Cramer-Rao lower bound (CRLB). We simplified the 3-D position-sensitive detector to 2-D angular discrimination design. This design is capable of positioning the incident angle of 511 keV gamma rays. Excellent angular discrimination performance can be achieved except some particular angular positions at 0 degrees, 90 degrees, 180 degrees and 270 degrees. And the angular discrimination performance can be improved with more counts. Besides, we performed a preliminary experiment with 4 BGO crystal blocks and for all the tested angular positions ranging from 15 degrees to 75 degrees with an increment of 15 degrees, the maximum error was less than 6.5 degrees. Besides, we are now developing the positioning technology in a monolithic crystal which can be applied to the gamma imaging method. From the analytical calculation and experimental results, we conclude that the proposed 4 4 pi gamma imaging method with 3-D position-sensitive detector is effective and capable of searching for radioactive sources with excellent accuracy.
引用
收藏
页数:3
相关论文
共 50 条
  • [1] Detection of gamma ray polarization using a 3-D position-sensitive CdZnTe detector
    Xu, D
    He, Z
    Zhang, F
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 1160 - 1164
  • [2] BEAM TESTS OF A 3-D POSITION-SENSITIVE SCINTILLATION DETECTOR
    HALL, CJ
    AGRINIER, B
    BYARD, K
    DEAN, AJ
    GOLDWURM, A
    HARDING, JS
    LABANTI, C
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 863 - 865
  • [3] Time-Encoded Gamma-Ray Imaging Using a 3-D Position-Sensitive CdZnTe Detector Array
    Brown, Steven T.
    Goodman, David
    Chu, Jiyang
    Williams, Bennett
    Williamson, Martin R.
    He, Zhong
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2020, 67 (02) : 464 - 472
  • [4] Analysis of detector response using 3-D position-sensitive CZT gamma-ray spectrometers
    Zhang, F
    He, Z
    Xu, D
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (06) : 3098 - 3104
  • [5] A POSITION-SENSITIVE DETECTOR FOR A GAMMA-RAY IMAGING TELESCOPE
    CARTER, JN
    CHARALAMBOUS, P
    DEAN, AJ
    STEPHEN, JB
    BUTLER, RC
    DICOCCO, G
    MORELLI, E
    SPADA, G
    SPIZZICHINO, A
    BARBARESCHI, L
    BOELLA, G
    PEROTTI, F
    VILLA, G
    BADIALI, M
    LAPADULA, C
    POLCARO, F
    UBERTINI, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 196 (2-3): : 477 - 482
  • [6] Realization and applications of collimator-less gamma-ray imaging systems
    Vetter, K
    RADIOANALYTICAL METHODS IN INTERDISCIPLINARY RESEARCH: FUNDAMENTALS IN CUTTING-EDGE APPLICATIONS, 2004, 868 : 52 - 75
  • [7] A high sensitivity 4π view gamma imager with a monolithic 3D position-sensitive detector
    Ye, Qing
    Fan, Peng
    Wang, Rui
    Lyu, Zhenlei
    Hu, Ankang
    Wei, Qingyang
    Xia, Yan
    Yao, Rutao
    Liu, Yaqiang
    Ma, Tianyu
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 937 (31-40): : 31 - 40
  • [8] Development and performance verification of a 3-D position-sensitive Compton camera for imaging MeV gamma rays
    Hiroki Hosokoshi
    Jun Kataoka
    Saku Mochizuki
    Masaki Yoneyama
    Soichiro Ito
    Hiroaki Kiji
    Fumiya Nishi
    Shuji Miyamoto
    Tatsushi Shima
    Scientific Reports, 9
  • [9] Development and performance verification of a 3-D position-sensitive Compton camera for imaging MeV gamma rays
    Hosokoshi, Hiroki
    Kataoka, Jun
    Mochizuki, Saku
    Yoneyama, Masaki
    Ito, Soichiro
    Kiji, Hiroaki
    Nishi, Fumiya
    Miyamoto, Shuji
    Shima, Tatsushi
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [10] Realization and applications of collimator-less gamma-ray imaging systems.
    Vetter, K
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 223 : B156 - B156