Influence of calcium on glucose biosensor response and on hydrogen peroxide detection

被引:0
|
作者
Labat-Allietta, Nathalie [1 ]
Thévenot, Daniel R. [1 ]
机构
[1] Lab. de Bioelectrochimie et A., Faculte de Sciences et Technologie, Universite Paris XII-Val de Marne, 61 Ave. du General de Gaulle, 94010 Creteil, Cedex, France
来源
Biosensors and Bioelectronics | 1998年 / 13卷 / 01期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:19 / 29
相关论文
共 50 条
  • [21] A biosensor for hydrogen peroxide detection based on electronic properties of carbon nanotubes
    Majidi, Roya
    MOLECULAR PHYSICS, 2013, 111 (01) : 89 - 93
  • [22] Electrospun Hemoglobin Microbelts Based Biosensor for Sensitive Detection of Hydrogen Peroxide
    Ding, Yu
    Wang, Ying
    Lei, Yu
    2011 IEEE 37TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC), 2011,
  • [23] Interpreting Heterogeneity in Response of Cells Expressing a Fluorescent Hydrogen Peroxide Biosensor
    Huang, Beijing K.
    Ali, Sohail
    Stein, Kassi T.
    Sikes, Hadley D.
    BIOPHYSICAL JOURNAL, 2015, 109 (10) : 2148 - 2158
  • [24] A Review on Glucose and Hydrogen Peroxide Biosensor Based on Modified Electrode Included Silver Nanoparticles
    Rad, Ali Shokuhi
    Mirabi, Ali
    Binaian, Ehsan
    Tayebi, Habibollah
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (08): : 3671 - 3683
  • [25] Newly Designed Amperometric Biosensor for Hydrogen Peroxide and Glucose Based on Vanadium Sulfide Nanoparticles
    Sarkar, Arpita
    Ghosh, Abhisek Brata
    Saha, Namrata
    Bhadu, Gopala Ram
    Adhikary, Bibhutosh
    ACS APPLIED NANO MATERIALS, 2018, 1 (03): : 1339 - 1347
  • [26] A BIOSENSOR FOR THE ANALYSIS OF HYDROGEN-PEROXIDE
    CHARPENTIER, L
    MURR, NE
    ANALUSIS, 1995, 23 (06) : 265 - 268
  • [27] Metallophthalocyanines and metalloporphyrins as electrocatalysts: a case of hydrogen peroxide and glucose detection
    Mashazi, Philani N.
    Nombona, Nolwazi
    Muchindu, Munkombwe
    Vilakazi, Sibulelo
    JOURNAL OF PORPHYRINS AND PHTHALOCYANINES, 2012, 16 (7-8) : 741 - 753
  • [28] PHOTOGRAPHIC DETECTION OF HYDROGEN-PEROXIDE AND GLUCOSE BY PEROXYOXALATE CHEMILUMINESCENCE
    NAKASHIMA, K
    KAWAGUCHI, S
    GIVENS, RS
    AKIYAMA, S
    ANALYTICAL SCIENCES, 1990, 6 (06) : 833 - 836
  • [29] Colorimetric detection of hydrogen peroxide and glucose using brominated graphene
    Singh, Shikha
    Mitra, Kheyanath
    Singh, Rajshree
    Kumari, Archana
    Sen Gupta, Susanta Kumar
    Misra, Nira
    Maiti, Pralay
    Ray, Biswajit
    ANALYTICAL METHODS, 2017, 9 (47) : 6675 - 6681
  • [30] Electroactive bacteria as whole-cell biosensor for sensitive detection of hydrogen peroxide
    Wen, Junlin
    He, Daigui
    Zhuo, Tongye
    Li, Wanqing
    Liu, Jianbo
    Wu, Jialin
    Zhao, Yurong
    Yuan, Yong
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2023, 11 (02):