Standardization of iodine-129 by the TDCR liquid scintillation method and 4π B-y coincidence counting

被引:0
|
作者
Cassette, P. [1 ]
Bouchard, J. [1 ]
Chauvenet, B. [1 ]
机构
[1] Laboratoire Primaire des Rayonnemets, Ionisants, Gif-sur-Yvette, France
关键词
Radiation counters - Radioactivity measurement - Standardization;
D O I
暂无
中图分类号
学科分类号
摘要
Iodine-129 is a long-lived fission product, with physical and chemical properties that make it a good candidate for evaluating the environmental impact of the nuclear energy fuel cycle. To avoid solid source preparation problems, liquid scintillation has been used to standardize this nuclide for a EUROMET intercomparison. Two methods were used to measure the iodine-129 activity: triple-to-double-coincidence ratio liquid scintillation counting and 4π β-γ coincidence counting; the results are in good agreements.
引用
收藏
页码:339 / 342
相关论文
共 49 条
  • [21] Activity standardization of 99mTc using liquid scintillation counting method
    Lee, K. B.
    Lee, Jong Man
    Park, Tae Soon
    Lee, Sang Han
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 316 (03) : 1047 - 1052
  • [22] Application of the Triple-to-Double Coincidence Ratio method at national institute of standards and technology for absolute standardization of radionuclides by liquid scintillation counting
    Zimmerman, BE
    Collé, R
    Cessna, JT
    Broda, R
    Cassette, P
    RADIOANALYTICAL METHODS IN INTERDISCIPLINARY RESEARCH: FUNDAMENTALS IN CUTTING-EDGE APPLICATIONS, 2004, 868 : 76 - 87
  • [23] Activity standardization by liquid scintillation counting and half-life measurements of 90Y
    Kossert, K
    Schrader, H
    APPLIED RADIATION AND ISOTOPES, 2004, 60 (05) : 741 - 749
  • [24] Standardization of 75Se by 4π(c, x)-γ coincidence counting method
    Park, T.S.
    Kim, I.S.
    Nuclear Instruments & Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1992, 312 (1-2):
  • [25] STANDARDIZATION AND HALF-LIFE OF TL-201 BY THE 4-PI(X,E)-GAMMA COINCIDENCE METHOD WITH LIQUID SCINTILLATION-COUNTING IN THE 4-PI-CHANNEL
    SIMPSON, BRS
    MEYER, BR
    APPLIED RADIATION AND ISOTOPES, 1994, 45 (06) : 669 - 673
  • [26] Improved activity standardization of 90Sr/90Y by means of liquid scintillation counting
    Kossert, Karsten
    Mougeot, Xavier
    APPLIED RADIATION AND ISOTOPES, 2021, 168 (168)
  • [27] SPECIAL PROBLEMS INVOLVED IN LIQUID SCINTILLATION COUNTING - STANDARDIZATION OF Y-87 AND GA-67
    STEYN, J
    NUCLEAR INSTRUMENTS & METHODS, 1973, 112 (1-2): : 137 - 141
  • [28] Accurate activity measurement of Lu-177 by the liquid scintillation 4πβ-γ coincidence counting technique
    Simpson, B. R. S.
    van Staden, M. J.
    Lubbe, J.
    van Wyngaardt, W. M.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 2209 - 2214
  • [29] DIRECT INCORPORATION METHOD FOR LIQUID SCINTILLATION COUNTING OF PLASMA SAMPLES BY INTERNAL-EXTERNAL STANDARDIZATION
    BADER, C
    ASSAILLY, J
    CHANARD, J
    FUNCKBRE.JL
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1973, 24 (01): : 29 - 36
  • [30] Separation and activity standardization of 226Ra by 4pa liquid scintillation counting
    Blud'ovsky, Richard
    Sukova, Vlasta
    APPLIED RADIATION AND ISOTOPES, 2022, 188