Activity standardization by liquid scintillation counting and half-life measurements of 90Y

被引:33
|
作者
Kossert, K [1 ]
Schrader, H [1 ]
机构
[1] Phys Tech Bundesanstalt, Dept 6 1, D-38116 Braunschweig, Germany
关键词
liquid scintillation counting; CIEMAT/NIST method; ionization chamber; half-life measurement; Y-90; radionuclide impurity;
D O I
10.1016/j.apradiso.2003.12.009
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Radioactive Y-90 was standardized by means of 47pibeta liquid scintillation efficiency tracing with a two-phototube counting system. The efficiencies of Y-90 and the tracer H-3 are related by the CIEMAT/NIST method. The dependence of the calculated efficiency on various shape factors and the importance of accurately measuring the radionuclide impurity of Sr-90 are discussed. The half-life of Y-90 was measured with improved accuracy by means of a liquid scintillation counting and a 4pi ionization chamber measuring system, and an average value T-1/2 = 64.053(20) h was found. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:741 / 749
页数:9
相关论文
共 50 条
  • [1] Improved activity standardization of 90Sr/90Y by means of liquid scintillation counting
    Kossert, Karsten
    Mougeot, Xavier
    APPLIED RADIATION AND ISOTOPES, 2021, 168 (168)
  • [2] Standardization of 90Y solution by mean of a Cherenkov counting in comparison with a liquid scintillation counting technique
    Ziemek, Tomasz
    Lech, Edyta
    Tyminski, Zbigniew
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2022, 331 (08) : 3327 - 3333
  • [3] Standardization of 90Y solution by mean of a Cherenkov counting in comparison with a liquid scintillation counting technique
    Tomasz Ziemek
    Edyta Lech
    Zbigniew Tymiński
    Journal of Radioanalytical and Nuclear Chemistry, 2022, 331 : 3327 - 3333
  • [4] Activity standardization by means of liquid scintillation counting and determination of the half-life of 89Zr
    Kossert, Karsten
    Nahle, OleJ. J.
    Honig, Anja
    Rottger, Stefan
    APPLIED RADIATION AND ISOTOPES, 2022, 181
  • [5] Half-life measurements of 87Rb by liquid scintillation counting
    Kossert, K
    APPLIED RADIATION AND ISOTOPES, 2003, 59 (5-6) : 377 - 382
  • [6] Efficiency calibration of a liquid scintillation counter for 90Y Cherenkov counting
    Universidad de Huelva, Huelva, Spain
    Nucl Instrum Methods Phys Res Sect A, 2 (267-275):
  • [7] Efficiency calibration of a liquid scintillation counter for 90Y Cherenkov counting
    Vaca, F
    Manjon, G
    Garcia-Leon, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 406 (02): : 267 - 275
  • [8] Determination of 68Ga half-life by Liquid Scintillation Counting
    Marganiec-Galazka, Justyna
    Kaminski, Aleksander
    Lech, Edyta
    Listkowska, Anna
    Saganowski, Pawel
    Tyminski, Zbigniew
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2025,
  • [9] Half-life evaluations for 3H, 90Sr, and 90Y
    MacMahon, Desmond
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (10-11) : 1417 - 1419
  • [10] Rapid determination of 90Sr/90Y in water samples by liquid scintillation and Cherenkov counting
    Olfert, Jennifer M.
    Dai, Xiongxin
    Kramer-Tremblay, Sheila
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 300 (01) : 263 - 267