ULTRALOW BACKGROUND GERMANIUM GAMMA-RAY SPECTROMETER.

被引:0
|
作者
Brodzinski, Ronald [1 ]
Brown, Donald P. [1 ]
Evans Jr., John C. [1 ]
Hensley, Walter K. [1 ]
Reeves, James H. [1 ]
Wogman, Ned A. [1 ]
Avignone III, Frank T. [1 ]
Miley, Harry S. [1 ]
机构
[1] Pacific Northwest Lab, Richland, WA,, USA, Pacific Northwest Lab, Richland, WA, USA
来源
关键词
There are many applications for a gamma-ray detector which has a background more than two orders of magnitude lower than a standard; low background; intrinsic-Ge; Compton-suppressed spectrometer; including the study of neutrinoless and two-neutrino double beta decay. This paper describes a series of experiments performed to develop an ultralow background detector with a 135 cm' intrinsic Ge diode in three different environments . The baseline experiment involved a typical low level counting facility . Sources of background were identified; and a baseline background was measured as a function of energy . An extensive program; carried out over several years; identified clean sources of material and evaluated their radiopurity. A cooperative program between the Pacific Northwest Laboratory (PNL); the University of South Carolina (USC); and Princeton Gamma Tech; Inc. (PGT) was developed; and a new cryostat was built from materials identified from the radiopurity measurements. The detector was then tested above ground in a combination bulk and partial cosmic-ray anticoincidence shield . The detector was then moved to a site in the Homestake gold mine in Lead; South Dakota; where 1438 m of rock overburden provided a water-equivalent thickness for cosmic ray at- * This work was supported by the US Department of Energy under Contract No . DE-AC06-76RLO 1830 and the Na-tional Science Foundation under Grant No . PHY-ß2o9562;
D O I
暂无
中图分类号
学科分类号
摘要
5
引用
收藏
页码:207 / 213
相关论文
共 50 条
  • [41] PULSE SHAPE-DISCRIMINATION FOR BACKGROUND REJECTION IN GERMANIUM GAMMA-RAY DETECTORS
    FEFFER, PT
    SMITH, DM
    CAMPBELL, RD
    PRIMBSCH, JH
    LIN, RP
    LUKE, PN
    MADDEN, NW
    PEHL, RH
    MATTESON, JL
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY AND ATOMIC PHYSICS, 1989, 1159 : 287 - 294
  • [43] COMPUTER DESIGN OF A LOW BACKGROUND GERMANIUM DETECTOR FOR ASTROPHYSICAL GAMMA-RAY SPECTROSCOPY
    SLASSISENNOU, AS
    ALBERNHE, F
    VEDRENNE, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 305 (01): : 200 - 207
  • [44] The extragalactic gamma-ray background
    Stecker, FW
    Salamon, MH
    GAMMA 2001, 2001, 587 : 432 - 441
  • [45] COSMIC GAMMA-RAY BACKGROUND
    BHATIA, VB
    TANDON, JN
    ASTROPHYSICAL LETTERS & COMMUNICATIONS, 1971, 8 (02) : 99 - &
  • [46] The guaranteed gamma-ray background
    Pavlidou, V
    Fields, BD
    ASTROPHYSICAL JOURNAL, 2002, 575 (01): : L5 - L8
  • [47] Background deduction of the Chang'E-1 gamma-ray spectrometer data
    ZHANG Liyan1
    Acta Geochimica, 2012, (03) : 234 - 241
  • [48] Gamma-Ray Background: A Review
    Kneiske, T. M.
    CHINESE JOURNAL OF ASTRONOMY AND ASTROPHYSICS, 2008, 8 : 219 - 225
  • [49] FSRQ and the gamma-ray background
    diGirolamo, T
    Comastri, A
    Setti, G
    EXTRAGALACTIC RADIO SOURCES, 1996, (175): : 595 - 596
  • [50] SPECTROMETER WITH A SINGLE ORGANIC SCINTILLATOR FOR GAMMA-RAY SPECTROMETRY AGAINST A NEUTRON BACKGROUND