Platelet activation following rotary pump speed increase

被引:0
|
作者
Snyder, T.A. [1 ]
Watach, M.J. [1 ]
Litwak, K.N. [1 ]
Wagner, W.R. [1 ]
机构
[1] McGowan Center for Artificial Organ Development, University of Pittsburgh, Pittsburgh, PA, United States
关键词
Axial flow ventricular assist devices - Blood damage - Flow cytometric assay - Hemolysis - Platelet activation - Standard femoral cannulation - Thromboembolic risk;
D O I
10.1097/00002480-200003000-00096
中图分类号
学科分类号
摘要
Axial flow ventricular assist devices represent the next generation of heart assist devices. Blood damage may result from the high shear field produced by these devices. Blood damage has previously been quantified in terms of hemolysis. Shear induced platelet activation remains a concern. This phenomenon was assessed using several flow cytometric assays we have developed to the quantify in vivo circulating activated platelets (ACT-PLT), circulating platelet microaggregates (AGG-PLT), platelet consumption and platelet life span. The assays were used to measure platelet activation before, during, and after a step increase in the pump revolutions per minute (RPMs) in three calves implanted with the UOP/Nimbus axial flow ventricular assist device. A marked increase in ACT-PLTs and AGG-PLTs immediately followed the RPM increase, with recovery in these parameters over time. Platelet life span decreased from 102 ± 10 hours before the RPM change to 83 ± 14 hours (p<0.05) after the step increase. This corresponded to a 10 ± 4% increase in average daily platelet consumption. These measurements could ultimately be used to define a tolerable RPM operating range as well as the effect of the rate of RPM change on platelet activation. Control algorithms might utilize such information to minimize platelet activation and reduce thromboembolic risk.
引用
收藏
相关论文
共 50 条
  • [31] PUMPING SPEED MEASUREMENT OF THE ROTARY VANE VACUUM PUMP BY USING NUMERICAL AND EXPERIMENTAL APPROACHES
    Azam, M. Nadeem
    Umar, M.
    Maqsood, M.
    Akhtar, Imran
    Aziz, Imran
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2014, VOL 7, 2015,
  • [32] Physiologic outcome of varying speed rotary blood pump support algorithms: a review study
    Bozkurt, Selim
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (01) : 13 - 28
  • [33] Physiologic outcome of varying speed rotary blood pump support algorithms: a review study
    Selim Bozkurt
    Australasian Physical & Engineering Sciences in Medicine, 2016, 39 : 13 - 28
  • [34] Rotary blood pump flow spontaneously increases during exercise under constant pump speed: Results of a chronic study
    Akimoto, T
    Yamazaki, K
    Litwak, P
    Litwak, KN
    Tagusari, O
    Mori, T
    Antaki, JF
    Kameneva, MV
    Watach, MJ
    Umezu, M
    Tomioka, J
    Kormos, RL
    Koyanagi, H
    Griffith, BP
    ARTIFICIAL ORGANS, 1999, 23 (08) : 797 - 801
  • [36] Catheter based intracoronary brachytherapy leads to an increase in platelet activation
    Jaster, M
    Pauschinger, M
    Rosenthal, T
    Schwimmbeck, P
    Schultheiss, HP
    Rauch, U
    EUROPEAN HEART JOURNAL, 2001, 22 : 392 - 392
  • [37] HIGH-SPEED ROTARY BITS CUT COST PER FT, INCREASE ROP
    DEANE, JD
    DOIRON, HH
    TOMPKINS, LB
    WORLD OIL, 1984, 198 (06) : 115 - &
  • [38] CHANGES IN NEUROPSYCHOLOGICAL FUNCTIONING FOLLOWING AN ABNORMAL INCREASE IN PLATELET LEVELS
    ZYCH, KA
    SPECTOR, J
    BOLTER, JF
    INTERNATIONAL JOURNAL OF CLINICAL NEUROPSYCHOLOGY, 1985, 7 (01): : 64 - 64
  • [39] PLATELET DERIVED EXOSOMES FOLLOWING TRAUMA INCREASE THROMBUS BURDEN
    Liu, Yingjie
    Dyer, Mitchell R.
    Haldeman, Shannon
    Neal, Matthew D.
    SHOCK, 2018, 49 (06): : 115 - 116
  • [40] Platelet factor XI: intracellular localization and mRNA splicing following platelet activation
    Zucker, M.
    Hauschner, H.
    Seligsohn, U.
    Rosenberg, N.
    BLOOD CELLS MOLECULES AND DISEASES, 2018, 69 : 30 - 37