Highly sensitive method for measuring time constant of fluorescence

被引:0
|
作者
Huang, Songjun [1 ]
Liu, Lie [1 ]
Chao, Hui [1 ]
机构
[1] Univ of National Defence Science and, Technology, Changsha, China
来源
关键词
Optical variables measurement;
D O I
暂无
中图分类号
TH74 [光学仪器];
学科分类号
0803 ;
摘要
A new technique for measuring time constant of fluorescence was introduced. Its time resolution can attain 1ps and the incident light energy required is only 10-1.7J. Its measuring principle diagram was given and the working principle of the system was described in detail. This new measuring technique has been successfully used in the measurement of the weak fluorescence of human gallbladder to determine the existence of tiny gallstone.
引用
收藏
页码:169 / 170
相关论文
共 50 条
  • [11] Electrophoresis of creatine kinase isoforms: a highly sensitive fluorescence scanning method
    Zhao, X
    Bi, CL
    Yang, ZH
    CHINESE MEDICAL JOURNAL, 1999, 112 (04) : 312 - 315
  • [12] Electrophoresis of creatine kinase isoforms:a highly sensitive fluorescence scanning method
    赵昕
    毕春雷
    杨振华
    Chinese Medical Journal, 1999, (04)
  • [13] A HIGHLY SENSITIVE METHOD FOR ANALYSES OF SUGAR MOIETIES OF GLYCOPROTEINS BY FLUORESCENCE LABELING
    HASE, S
    IKENAKA, T
    MATSUSHIMA, Y
    JOURNAL OF BIOCHEMISTRY, 1981, 90 (02): : 407 - 414
  • [14] TIME CORRELATION METHOD FOR MEASURING FLUORESCENCE DECAYS WITH A CW LASER
    DORSEY, CC
    PELLETIER, MJ
    HARRIS, JM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1979, 50 (03): : 333 - 336
  • [15] Time-between-photons method for measuring fluorescence lifetimes
    Yasuhiro Mizutani
    Kohta Shinagawa
    Takahiko Mizuno
    Tetsuo Iwata
    Optical Review, 2013, 20 : 1 - 6
  • [16] Time-Between-Photons Method for Measuring Fluorescence Lifetimes
    Mizutani, Yasuhiro
    Shinagawa, Kohta
    Mizuno, Takahiko
    Iwata, Tetsuo
    OPTICAL REVIEW, 2013, 20 (01) : 1 - 6
  • [17] Constant gradient FEXSY: A time-efficient method for measuring exchange
    Scher, Yuval
    Reuveni, Shlomi
    Cohen, Yoram
    JOURNAL OF MAGNETIC RESONANCE, 2020, 311
  • [18] NEW METHOD OF MEASURING THE THERMAL TIME CONSTANT OF JUNCTION LASERS.
    Fujita, Osamu
    1600, (57):
  • [19] A Highly Accurate Method for Measuring Response Time of MEMS Thermopiles
    Xiang, Zeqing
    Shi, Meng
    Zhou, Na
    Zhang, Chenchen
    Ding, Xuefeng
    Ni, Yue
    Chen, Dapeng
    Mao, Haiyang
    MICROMACHINES, 2022, 13 (10)
  • [20] A Highly Sensitive Anion Exchange Chromatography Method for Measuring cGAS Activity in vitro
    Holleufer, Andreas
    Hartmann, Rune
    BIO-PROTOCOL, 2018, 8 (20):