Highly sensitive method for measuring time constant of fluorescence

被引:0
|
作者
Huang, Songjun [1 ]
Liu, Lie [1 ]
Chao, Hui [1 ]
机构
[1] Univ of National Defence Science and, Technology, Changsha, China
来源
关键词
Optical variables measurement;
D O I
暂无
中图分类号
TH74 [光学仪器];
学科分类号
0803 ;
摘要
A new technique for measuring time constant of fluorescence was introduced. Its time resolution can attain 1ps and the incident light energy required is only 10-1.7J. Its measuring principle diagram was given and the working principle of the system was described in detail. This new measuring technique has been successfully used in the measurement of the weak fluorescence of human gallbladder to determine the existence of tiny gallstone.
引用
收藏
页码:169 / 170
相关论文
共 50 条
  • [1] SENSITIVE METHOD FOR MEASURING A CONSTANT ATOMIC POPULATION BY OPTICAL-ABSORPTION
    BRUNETEA.AM
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1974, 7 (09): : 738 - 740
  • [2] A simple and highly sensitive method of measuring heme oxygenase activity
    Pham Hieu Liem
    Mu, Anfeng
    Kikuta, Shun-ichi
    Ohta, Kazushi
    Kitajima, Sakihito
    Taketani, Shigeru
    BIOLOGICAL CHEMISTRY, 2015, 396 (11) : 1265 - 1268
  • [3] Highly sensitive inhibitory kinetics fluorescence method for determination of arsenic
    Li, Guirong
    Liu, Yunfu
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2011, 91 (09) : 866 - 875
  • [4] Fluorescence intensity and lifetime distribution analysis: A new and highly sensitive fluorescence fluctuation method
    Gall, K
    Palo, K
    Brand, L
    Eggeling, C
    Kask, P
    BIOPHYSICAL JOURNAL, 2002, 82 (01) : 355A - 355A
  • [6] Highly sensitive TVIST television-computer measuring system for fluorescence endoscopy and microscopy
    Papayan, GV
    Mantsvetov, AA
    JOURNAL OF OPTICAL TECHNOLOGY, 2000, 67 (01) : 58 - 64
  • [7] A specific and highly sensitive method for measuring extracellular superoxide from cells
    Haigh, Stephen
    Bordan, Zsuzsanna
    Batori, Robert
    Sellers, Hunter
    Barman, Scott
    Fulton, David
    FREE RADICAL BIOLOGY AND MEDICINE, 2022, 180 : 61 - 62
  • [8] A highly sensitive, accurate, and stable method for measuring pectin depolymerase activity
    Liu, Yinchun
    Liu, Fang
    Liu, Jianrui
    Dong, Jingwen
    Xing, Mingxia
    Chen, Xiangyu
    Wu, Ya'nan
    Ai, Tianxi
    Zhang, Yongqin
    FOOD CHEMISTRY, 2025, 463
  • [9] Measuring Orexin in body fluids: A new robust highly sensitive method
    Jeske, A.
    Hinze-Selch, D.
    PHARMACOPSYCHIATRY, 2007, 40 (05) : 244 - 244
  • [10] Electrophoresis of creatine kinase isoforms:a highly sensitive fluorescence scanning method
    赵昕
    毕春雷