ANALYSIS OF TORSIONAL VIBRATION SYSTEM CONSISTING OF CROSS-FLOW FAN AND FAN MOTOR.

被引:0
|
作者
Fukushima, Masafumi
Murano, Katsuhiro
Hirose, Toru
机构
来源
| 1978年 / 24卷 / 05期
关键词
TORSIONAL VIBRATION SYSTEM;
D O I
暂无
中图分类号
学科分类号
摘要
The requirements for noise reduction of split-type air conditioners are becoming more and more strict, and many air conditioners in today's market are achieving an indoor noise level below 30 dB(A) at low fan speed operation. During such low noise level operation, the noise problem of air conditioners is usually produced by the electric vibration of the motor, rather than by the ventilating function of the blower fan. In particular, the vibration of a doubled power supply frequency (double-frequency vibration), which is produced by the rotating axis system of the motor, is the main cause of the noise problem in many cases. In order to solve such noise problems caused by double-frequency vibration, an analysis study has been conducted with the following suppositions: 1) The fan (cross-flow fan) is an elastic bar; 2) The fan and rotor of the motor jointly form a torsional vibration system. When characteristic constants of certain elements of the torsional vibration system are measured, it is possible to predict the response characteristics of double-frequency vibration on the system. Then, it is possible to solve the air conditioner noise problem effectively.
引用
收藏
页码:796 / 803
相关论文
共 50 条
  • [31] Window purifying ventilator using a cross-flow fan: Simulation and optimization
    Li, Jiayu
    Hou, Yuefei
    Liu, Junjie
    Wang, Zhiqiang
    Li, Fei
    BUILDING SIMULATION, 2016, 9 (04) : 481 - 488
  • [32] Forces on apple trees sprayed with a cross-flow fan air jet
    Svensson, SA
    Fox, RD
    Hansson, PA
    TRANSACTIONS OF THE ASAE, 2002, 45 (04): : 889 - 895
  • [33] Numerical and experimental study of a cross-flow fan for combine cleaning shoes
    Gebrehiwot, Mekonnen Gebreslasie
    De Baerdemaeker, Josse
    Baelmans, Martine
    BIOSYSTEMS ENGINEERING, 2010, 106 (04) : 448 - 457
  • [34] Window purifying ventilator using a cross-flow fan: Simulation and optimization
    Jiayu Li
    Yuefei Hou
    Junjie Liu
    Zhiqiang Wang
    Fei Li
    Building Simulation, 2016, 9 : 481 - 488
  • [35] Study on Helicopter Antitorque Device Based on Cross-Flow Fan Technology
    Du Siliang
    Tang Zhengfei
    Xu Pei
    Ji Mengjiang
    INTERNATIONAL JOURNAL OF AEROSPACE ENGINEERING, 2016, 2016
  • [36] Performance of a cross-flow fan with various shapes of a rearguider and an exit duct
    Kim, Tae-An
    Kim, D-W.
    Park, S-K.
    Kim, Youn J.
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2008, 22 (10) : 1876 - 1882
  • [37] Axial Fan Blade Vibration Assessment under Inlet Cross-Flow Conditions Using Laser Scanning Vibrometry
    Heinemann, Till
    Becker, Stefan
    APPLIED SCIENCES-BASEL, 2017, 7 (08):
  • [38] INTERNAL FLOW AND NOISE INVESTIGATIONS ABOUT THE CROSS-FLOW FAN WITH DIFFERENT BLADE ANGLES
    Li, You
    Ouyang, Hua
    Tian, Jie
    Zheng, Zhiming
    Du, Zhaohui
    PROCEEDINGS OF THE ASME TURBO EXPO 2010: TURBOMACHINERY: AXIAL FLOW FAN AND COMPRESSOR AERODYNAMICS DESIGN METHODS, AND CFD MODELING FOR TURBOMACHINERY, VOL 7, PTS A-C, 2010, : 2845 - 2855
  • [39] Internal Flow and Noise Investigations About the Cross-Flow Fan With Different Blade Angles
    Ouyang, Hua
    Tian, Jie
    Li, You
    Zheng, Zhiming
    Du, Zhaohui
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2012, 134 (05):
  • [40] On cross-flow fan theoretical performance and efficiency curves: An energy loss analysis on experimental data
    Toffolo, A
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (05): : 743 - 751