ANALYSIS OF TORSIONAL VIBRATION SYSTEM CONSISTING OF CROSS-FLOW FAN AND FAN MOTOR.

被引:0
|
作者
Fukushima, Masafumi
Murano, Katsuhiro
Hirose, Toru
机构
来源
| 1978年 / 24卷 / 05期
关键词
TORSIONAL VIBRATION SYSTEM;
D O I
暂无
中图分类号
学科分类号
摘要
The requirements for noise reduction of split-type air conditioners are becoming more and more strict, and many air conditioners in today's market are achieving an indoor noise level below 30 dB(A) at low fan speed operation. During such low noise level operation, the noise problem of air conditioners is usually produced by the electric vibration of the motor, rather than by the ventilating function of the blower fan. In particular, the vibration of a doubled power supply frequency (double-frequency vibration), which is produced by the rotating axis system of the motor, is the main cause of the noise problem in many cases. In order to solve such noise problems caused by double-frequency vibration, an analysis study has been conducted with the following suppositions: 1) The fan (cross-flow fan) is an elastic bar; 2) The fan and rotor of the motor jointly form a torsional vibration system. When characteristic constants of certain elements of the torsional vibration system are measured, it is possible to predict the response characteristics of double-frequency vibration on the system. Then, it is possible to solve the air conditioner noise problem effectively.
引用
收藏
页码:796 / 803
相关论文
共 50 条
  • [21] Performance and internal flow of cross-flow fan with inlet guide vane
    Fukutomi, J
    Nakamura, R
    JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 2005, 48 (04) : 763 - 769
  • [22] Air jet velocities from a cross-flow fan sprayer
    Fox, R.D.
    Brazee, R.D.
    Svensson, S.A.
    Reichard, D.L.
    Transactions of the American Society of Agricultural Engineers, 1992, 35 (05): : 1381 - 1384
  • [24] Numerical Study on Fluid Dynamic Characteristics of a Cross-Flow Fan
    Cai, Xiaowei
    Zhang, Chun
    Wang, Baoshou
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2023, 11 (04)
  • [25] Attenuation of Cross-Flow Fan Noise Using Porous Stabilizers
    Lai, Huanxin
    Wang, Meng
    Yun, Chuye
    Yao, Jin
    INTERNATIONAL JOURNAL OF ROTATING MACHINERY, 2011, 2011
  • [26] NOISE CONTROLLING USING POROUS STABILIZERS IN A CROSS-FLOW FAN
    Lai, Huanxin
    Zhang, Hongbo
    Yao, Jin
    Xing, Gailan
    PROCEEDINGS OF THE ASME TURBO EXPO 2012, VOL 3, 2012, : 665 - +
  • [27] An experimental investigation of the flow field pattern within the impeller of a cross-flow fan
    Toffolo, A
    Lazzaretto, A
    Martegani, AD
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2004, 29 (01) : 53 - 64
  • [28] Performance of a cross-flow fan with various shapes of a rearguider and an exit duct
    Tae-An Kim
    D. -W. Kim
    S. -K. Park
    Youn J. Kim
    Journal of Mechanical Science and Technology, 2008, 22 : 1876 - 1882
  • [29] AIR-JET VELOCITIES FROM A CROSS-FLOW FAN SPRAYER
    FOX, RD
    BRAZEE, RD
    SVENSSON, SA
    REICHARD, DL
    TRANSACTIONS OF THE ASAE, 1992, 35 (05): : 1381 - 1382
  • [30] Computational and experimental study of a cross-flow fan for combine cleaning shoes
    Gebrehiwot, M. G.
    De Baerdemaeker, J.
    Baelmans, M.
    CONFERENCE: AGRICULTURAL ENGINEERING - LAND-TECHNIK AGENG 2009: INNOVATIONS TO MEET FUTURE CHALLENGES, 2009, 2060 : 387 - 392