Magnetic field exposure device for patch-clamp measuring system

被引:0
|
作者
Obo, M.
Otaka, Y.
Kitamura, S.
机构
关键词
Electric currents - Function generators - Magnetic field effects - Microscopic examination;
D O I
暂无
中图分类号
学科分类号
摘要
A device was developed that enables in situ optical and electrical observations of a single cell under exposure to a magnetic field. Electric current through a flat conductor sheet made a homogeneous magnetic field above the sheet. The sheet was made of brass, 30 mm × 30 mm to 60 mm × 660 mm and 0.3 mm thick, with a hole 2 mm in diameter in the center of the sheet for the light path of a microscope. An electric current of diverse waveforms was supplied by a function generator through an amplifier, generating a magnetic field of the same waveform up to 0.14 mT. The sheet was laid concentrically on the stage of a microscope. The homogeneity of the field over a 40 mm × 40 mm sheet was estimated to be 5% in the vertical and 0.1% in the horizontal directions for a 1 mm shift of a cell. A sheet does not hinder movement of the patch-clamp attachments and leaves space for a pair of coils to compensate the geomagnetic field on the stage of the microscope. The electric noise caused by the field was so small that it could be canceled in the data collection process.
引用
收藏
页码:197 / 202
相关论文
共 50 条
  • [31] A novel method for patch-clamp automation
    D. Vasilyev
    T. Merrill
    A. Iwanow
    J. Dunlop
    M. Bowlby
    Pflügers Archiv, 2006, 452 : 240 - 247
  • [32] THE PATCH-CLAMP TECHNIQUE IN THE STUDY OF SECRETION
    PENNER, R
    NEHER, E
    TRENDS IN NEUROSCIENCES, 1989, 12 (04) : 159 - 163
  • [33] Microfluidics and patch-clamp based sensors
    Farre, C
    Sinclair, J
    Karlsson, M
    GENETIC ENGINEERING NEWS, 2004, 24 (21): : 36 - +
  • [34] A DIRECT-READING DEVICE FOR MEASUREMENT OF PATCH-CLAMP MICROPIPETTE TIP DIAMETERS
    MARTIN, DK
    COOK, DI
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1990, 417 (03): : 255 - 258
  • [35] A LOW-COST VOLTAGE STEPPER DEVICE FOR USE IN PATCH-CLAMP EXPERIMENTS
    GITTER, AH
    THEIS, J
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1987, 408 (02): : 194 - 195
  • [36] A Computer-assisted Multi-electrode Patch-clamp System
    Perin, Rodrigo
    Markram, Henry
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2013, (80):
  • [37] PCR AND PATCH-CLAMP ANALYSIS OF SINGLE NEURONS
    SUCHER, NJ
    DEITCHER, DL
    NEURON, 1995, 14 (06) : 1095 - 1100
  • [38] Patch-clamp detection of neurotransmitters in capillary electrophoresis
    Orwar, O
    Jardemark, K
    Jacobson, I
    Moscho, A
    Fishman, HA
    Scheller, RH
    Zare, RN
    SCIENCE, 1996, 272 (5269) : 1779 - 1782
  • [39] Patch-Clamp Fluorometry: Electrophysiology meets Fluorescence
    Kusch, Jana
    Zifarelli, Giovanni
    BIOPHYSICAL JOURNAL, 2014, 106 (06) : 1250 - 1257
  • [40] Priming and testing silicon patch-clamp neurochips
    Py, Christophe
    Denhoff, Michael W.
    Sabourin, Nicaulas
    Weber, John
    Shiu, Matthew
    Zhao, Ping
    NEW BIOTECHNOLOGY, 2014, 31 (05) : 430 - 435