A novel method for patch-clamp automation

被引:0
|
作者
D. Vasilyev
T. Merrill
A. Iwanow
J. Dunlop
M. Bowlby
机构
[1] Wyeth Research,Discovery Neuroscience
[2] Wyeth,Biomedical Engineering
来源
Pflügers Archiv | 2006年 / 452卷
关键词
Automation; Patch-clamp recordings; Ion channel; hERG; Drug discovery;
D O I
暂无
中图分类号
学科分类号
摘要
An increasing demand of the pharmaceutical industry for automated electrophysiological stations for ion channel drug discovery has recently resulted in the development of several commercial platforms for secondary and safety screening of ion channel modulators. These commercial systems have demonstrated an enhanced throughput, however, often at the expense of some quality-sensitive aspects of traditional patch-clamp recordings. To improve data quality and content, we have developed a patch-clamp robot that fully automates manual patch-clamp recordings, including patch pipette handling, gigaseal formation, obtaining whole-cell or perforated-cell configuration, drug application, and data acquisition. Utilization of glass micropipettes results in high-quality electrophysiological recordings with an overall success rate of about 30% in perforated-cell mode. A fast drug application system with low volume requirements (1–1.5 ml) allows the study of ligand-gated ion channels on a millisecond scale. As proof-of-concept, we present two assays developed for voltage-gated human ether-a-go-go-related and ligand-gated α7 nicotinic receptor ion channels. The system throughput was a single concentration–response curve every 30–40 min or 12–17 6-point concentration–response curves daily, representing a significant improvement of typical manual patch-clamp throughput. This system represents an efficient method for patch-clamp automation without the need for a complex and expensive electrophysiological set-up for cell visualization.
引用
下载
收藏
页码:240 / 247
页数:7
相关论文
共 50 条
  • [1] A novel method for patch-clamp automation
    Vasilyev, D.
    Merrill, T.
    Iwanow, A.
    Dunlop, J.
    Bowlby, M.
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 2006, 452 (02): : 240 - 247
  • [2] Patch-clamp method gets a makeover
    Neubert, HJ
    ANALYTICAL CHEMISTRY, 2002, 74 (17) : 459A - 459A
  • [3] SUPERCHARGING - A METHOD FOR IMPROVING PATCH-CLAMP PERFORMANCE
    ARMSTRONG, CM
    CHOW, RH
    BIOPHYSICAL JOURNAL, 1987, 52 (01) : 133 - 136
  • [4] Sperm Patch-Clamp
    Lishko, Polina
    Clapham, David E.
    Navarro, Betsy
    Kirichok, Yuriy
    CILIA, PT B, 2013, 525 : 59 - 83
  • [5] THE PATCH-CLAMP TECHNIQUE
    LIEM, LK
    SIMARD, JM
    SONG, YM
    TEWARI, K
    NEUROSURGERY, 1995, 36 (02) : 382 - 392
  • [6] Patch-clamp techniques
    Teulon, J
    M S-MEDECINE SCIENCES, 2004, 20 (05): : 550 - 550
  • [7] An integrated patch-clamp amplifier for high-throughput planar patch-clamp systems
    Weerakoon, Pujitha
    Culurciello, Eugenio
    Klemic, Kate
    Sigworth, Fred J.
    PROCEEDINGS OF 2008 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1-10, 2008, : 1808 - +
  • [8] Dendritic patch-clamp recording
    Davie, Jenny T.
    Kole, Maarten H. P.
    Letzkus, Johannes J.
    Rancz, Ede A.
    Spruston, Nelson
    Stuart, Greg J.
    Haeusser, Michael
    NATURE PROTOCOLS, 2006, 1 (03) : 1235 - 1247
  • [9] Patch-clamp amplifiers on a chip
    Weerakoon, Pujitha
    Culurciello, Eugenio
    Yang, Youshan
    Santos-Sacchi, Joseph
    Kindlmann, Peter J.
    Sigworth, Fred J.
    JOURNAL OF NEUROSCIENCE METHODS, 2010, 192 (02) : 187 - 192
  • [10] Dendritic patch-clamp recording
    Jenny T Davie
    Maarten H P Kole
    Johannes J Letzkus
    Ede A Rancz
    Nelson Spruston
    Greg J Stuart
    Michael Häusser
    Nature Protocols, 2006, 1 : 1235 - 1247