A novel method for patch-clamp automation

被引:0
|
作者
D. Vasilyev
T. Merrill
A. Iwanow
J. Dunlop
M. Bowlby
机构
[1] Wyeth Research,Discovery Neuroscience
[2] Wyeth,Biomedical Engineering
来源
Pflügers Archiv | 2006年 / 452卷
关键词
Automation; Patch-clamp recordings; Ion channel; hERG; Drug discovery;
D O I
暂无
中图分类号
学科分类号
摘要
An increasing demand of the pharmaceutical industry for automated electrophysiological stations for ion channel drug discovery has recently resulted in the development of several commercial platforms for secondary and safety screening of ion channel modulators. These commercial systems have demonstrated an enhanced throughput, however, often at the expense of some quality-sensitive aspects of traditional patch-clamp recordings. To improve data quality and content, we have developed a patch-clamp robot that fully automates manual patch-clamp recordings, including patch pipette handling, gigaseal formation, obtaining whole-cell or perforated-cell configuration, drug application, and data acquisition. Utilization of glass micropipettes results in high-quality electrophysiological recordings with an overall success rate of about 30% in perforated-cell mode. A fast drug application system with low volume requirements (1–1.5 ml) allows the study of ligand-gated ion channels on a millisecond scale. As proof-of-concept, we present two assays developed for voltage-gated human ether-a-go-go-related and ligand-gated α7 nicotinic receptor ion channels. The system throughput was a single concentration–response curve every 30–40 min or 12–17 6-point concentration–response curves daily, representing a significant improvement of typical manual patch-clamp throughput. This system represents an efficient method for patch-clamp automation without the need for a complex and expensive electrophysiological set-up for cell visualization.
引用
下载
收藏
页码:240 / 247
页数:7
相关论文
共 50 条
  • [41] Patch-clamp study of taste transduction mechanisms
    Sugimoto, K
    CHEMICAL SENSES, 1996, 21 (01) : 3 - 3
  • [42] Application of patch-clamp technique in life chemistry
    Yang, P
    Du, HZ
    Xue, SW
    PROGRESS IN CHEMISTRY, 2002, 14 (04) : 251 - 256
  • [43] An Integrated Patch-Clamp System with Dual Input
    Weerakoon, Pujitha
    Sigworth, Fred
    Kindlmann, Peter
    Santos-Sacchi, Joseph
    Yang, Youshan
    Culurciello, Eugenio
    2010 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, 2010, : 1523 - 1526
  • [44] A PIPETTE HOLDER FOR USE IN PATCH-CLAMP MEASUREMENTS
    BUISMAN, HP
    DEVOS, A
    YPEY, DL
    JOURNAL OF NEUROSCIENCE METHODS, 1990, 31 (02) : 89 - 91
  • [45] PATCH-CLAMP STUDIES OF HUMAN MITOCHONDRIAL CHANNELS
    MURPHY, RC
    KING, M
    DIWAN, JJ
    KINNALLY, KW
    MOLECULAR BIOLOGY OF THE CELL, 1995, 6 : 2527 - 2527
  • [46] An Integrated Patch-Clamp Potentiostat With Electrode Compensation
    Weerakoon, Pujitha
    Culurciello, Eugenio
    Klemic, Kathryn G.
    Sigworth, Fred J.
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2009, 3 (02) : 117 - 125
  • [47] Cleaning patch-clamp pipettes for immediate reuse
    Kolb, I.
    Stoy, W. A.
    Rousseau, E. B.
    Moody, O. A.
    Jenkins, A.
    Forest, C. R.
    SCIENTIFIC REPORTS, 2016, 6
  • [48] New polymer packaging for planar patch-clamp
    Sauter, F
    d'Hahan, NP
    Pudda, C
    Charles, R
    Sordel, T
    Garnier-Raveaud, S
    Chatelain, F
    2005 3rd IEEE/EMBS Special Topic Conference on Microtechnology in Medicine and Biology, 2005, : 363 - 364
  • [49] A simple perfusion system for patch-clamp studies
    Vorobjev, VS
    Sharonova, IN
    Haas, HL
    JOURNAL OF NEUROSCIENCE METHODS, 1996, 68 (02) : 303 - 307
  • [50] ONLINE ANALYSIS OF PATCH-CLAMP DATA WITH A MICROCOMPUTER
    FINDLAY, I
    FURLONG, GA
    JOURNAL OF PHYSIOLOGY-LONDON, 1984, 354 (SEP): : P25 - P25