Errors in ultrasonic scatterer size estimates due to phase and amplitude aberration

被引:0
|
作者
机构
[1] Gerig, Anthony
[2] Zagzebski, James
来源
Gerig, A. (algerig@wisc.edu) | 1600年 / Acoustical Society of America卷 / 115期
关键词
Acoustics - Attenuation - Backscattering - Computer simulation - Error correction - Statistical methods - Transducers;
D O I
暂无
中图分类号
学科分类号
摘要
Current ultrasonic scatterer size estimation methods assume that acoustic propagation is free of distortion due to large-scale variations in medium attenuation and sound speed. However, it has been demonstrated that under certain conditions in medical applications, medium inhomogeneities can cause significant field aberrations that lead to B-mode image artifacts. These same aberrations may be responsible for errors in size estimates and parametric images of scatterer size. This work derives theoretical expressions for the error in backscatter coefficient and size estimates as a function of statistical parameters that quantify phase and amplitude aberration, assuming a Gaussian spatial autocorrelation function. Results exhibit agreement with simulations for the limited region of parameter space considered. For large values of aberration decorrelation lengths relative to aberration standard deviations, phase aberration errors appear to be minimal, while amplitude aberration errors remain significant. Implications of the results for accurate backscatter and size estimation are discussed. In particular, backscatter filters are suggested as a method for error correction. Limitations of the theory are also addressed. The approach, approximations, and assumptions used in the derivation are most appropriate when the aberrating structures are relatively large, and the region containing the inhomogeneities is offset from the insonifying transducer. © 2004 Acoustical Society of America.
引用
收藏
相关论文
共 50 条
  • [31] INFLUENCE OF AMPLITUDE AND PHASE ERRORS ON MIGRATION RESULTS
    VANDERWAL, LF
    BERKHOUT, AJ
    GEOPHYSICAL PROSPECTING, 1984, 32 (03) : 425 - 453
  • [32] ERRORS IN POSTCENSAL POPULATION ESTIMATES DUE TO AGE REPORTING ERRORS ON DEATH CERTIFICATES
    SIRKEN, MG
    MURPHY, RS
    POPULATION INDEX, 1969, 35 (03) : 256 - 256
  • [33] Multitaper estimates of phase-amplitude coupling
    Lepage, Kyle Q.
    Fleming, Cavan N.
    Witcher, Mark
    Vijayan, Sujith
    JOURNAL OF NEURAL ENGINEERING, 2021, 18 (05)
  • [34] Ultrasonic flow metering errors due to pulsating flow
    Berrebi, J
    Martinsson, PE
    Willatzen, M
    Delsing, J
    FLOW MEASUREMENT AND INSTRUMENTATION, 2004, 15 (03) : 179 - 185
  • [35] PARTICLE SIZE-AMPLITUDE RELATIONS FOR ULTRASONIC ATOMIZER
    LOBDELL, DD
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1968, 43 (02): : 229 - &
  • [36] MEASUREMENT OF DEFECT SIZE IN MATERIALS WITH THE AMPLITUDE OF AN ULTRASONIC SIGNAL
    ERMOLOV, IN
    INDUSTRIAL LABORATORY, 1960, 26 (04): : 482 - 487
  • [37] The errors of estimates of the amplitude of harmonic signals in geophysical microcontroller measuring instruments
    Glinchenko, A. S.
    Tronin, O. A.
    MEASUREMENT TECHNIQUES, 2012, 55 (08) : 955 - 963
  • [38] The errors of estimates of the amplitude of harmonic signals in geophysical microcontroller measuring instruments
    A. S. Glinchenko
    O. A. Tronin
    Measurement Techniques, 2012, 55 : 955 - 963
  • [39] MAXIMUM APERTURE ANGLES AND PHASE ABERRATION OF CYLINDRICAL ULTRASONIC LENSES
    KANEVSKI.IN
    SOVIET PHYSICS ACOUSTICS-USSR, 1966, 12 (01): : 93 - &
  • [40] Correction Technique of Phase Aberration in Ultrasonic Synthetic Focusing Signal
    Yue, Hai-lin
    Luo, Lin
    Gao, Xiao-rong
    2014 IEEE FAR EAST FORUM ON NONDESTRUCTIVE EVALUATION/TESTING (FENDT), 2014, : 74 - 78