Errors in ultrasonic scatterer size estimates due to phase and amplitude aberration

被引:0
|
作者
机构
[1] Gerig, Anthony
[2] Zagzebski, James
来源
Gerig, A. (algerig@wisc.edu) | 1600年 / Acoustical Society of America卷 / 115期
关键词
Acoustics - Attenuation - Backscattering - Computer simulation - Error correction - Statistical methods - Transducers;
D O I
暂无
中图分类号
学科分类号
摘要
Current ultrasonic scatterer size estimation methods assume that acoustic propagation is free of distortion due to large-scale variations in medium attenuation and sound speed. However, it has been demonstrated that under certain conditions in medical applications, medium inhomogeneities can cause significant field aberrations that lead to B-mode image artifacts. These same aberrations may be responsible for errors in size estimates and parametric images of scatterer size. This work derives theoretical expressions for the error in backscatter coefficient and size estimates as a function of statistical parameters that quantify phase and amplitude aberration, assuming a Gaussian spatial autocorrelation function. Results exhibit agreement with simulations for the limited region of parameter space considered. For large values of aberration decorrelation lengths relative to aberration standard deviations, phase aberration errors appear to be minimal, while amplitude aberration errors remain significant. Implications of the results for accurate backscatter and size estimation are discussed. In particular, backscatter filters are suggested as a method for error correction. Limitations of the theory are also addressed. The approach, approximations, and assumptions used in the derivation are most appropriate when the aberrating structures are relatively large, and the region containing the inhomogeneities is offset from the insonifying transducer. © 2004 Acoustical Society of America.
引用
收藏
相关论文
共 50 条
  • [21] STATISTICAL ESTIMATES OF AMPLITUDE AND PHASE CORRECTIONS
    PISARENKO, VF
    GEOPHYSICAL JOURNAL OF THE ROYAL ASTRONOMICAL SOCIETY, 1970, 20 (01): : 89 - +
  • [22] Correction of aberration-induced phase errors in phase measuring deflectometry
    Zhang, Xiangchao
    Niu, Zhenqi
    Ye, Junqiang
    Xu, Min
    OPTICS LETTERS, 2021, 46 (09) : 2047 - 2050
  • [23] Phase aberration correction of ultrasonic phased array signals
    Zhao Xia
    Wang Zhaoba
    Liu Bin
    CISP 2008: FIRST INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, VOL 5, PROCEEDINGS, 2008, : 63 - 66
  • [24] Simulation of ultrasonic scattering from scatterer size distributions using Field II
    Whitson, Hayley M.
    Rosado-Mendez, Ivan M.
    Hale, Jonathan H.
    Hall, Timothy J.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2024, 155 (02): : 1406 - 1421
  • [25] PRECISION OF ULTRASONIC ESTIMATES OF INTRAOCULAR TUMOR SIZE
    RASK, R
    JENSEN, PK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1925 - 1925
  • [26] Errors in confocal fluorescence ratiometric imaging microscopy due to chromatic aberration
    Lin, Yuxiang
    Gmitro, Arthur F.
    APPLIED OPTICS, 2011, 50 (01) : 95 - 102
  • [27] Element size effect on phase aberration correction
    Liu, DLD
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (09) : 1212 - 1221
  • [28] Combined amplitude and phase filters for increased tolerance to spherical aberration
    Mezouari, S
    Harvey, AR
    JOURNAL OF MODERN OPTICS, 2003, 50 (14) : 2213 - 2220
  • [29] Phase Noise, Amplitude and TOI Measurement Errors
    Stern, Bob
    MICROWAVE JOURNAL, 2015, 58 (05) : 104 - +
  • [30] ANALYSIS OF AMPLITUDE AND PHASE ERRORS IN BILINEAR CONVOLVERS
    MORGAN, DP
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1982, 29 (03): : 159 - 159