Orthopedic implant fretting corrosion

被引:0
|
作者
Hallab, Nadim James [1 ,2 ]
Jacobs, Joshua J. [1 ]
机构
[1] Dept of Orthopedic Surgery, Rush-Presbyt.-St. Lukes Med. Center, Rush Medical College, Chicago, IL 60612, United States
[2] Department of Orthopedic Surgery, Rush Medical College, 1653 W. Congress Parkway, Chicago, IL 60612, United States
来源
Corrosion Reviews | 2003年 / 21卷 / 2-3期
关键词
Bone - Cyclic loads - Fretting corrosion - Interfaces (materials) - Pathology;
D O I
暂无
中图分类号
学科分类号
摘要
Fretting corrosion occurs to some extent on all load bearing metallic orthopedic implants. Fretting of total hip and knee replacements occurs at such places as the bone-stem interface, the stem-cement interface, and on the interfaces of modular connections between implant components. Fretting also occurs at areas of cyclic load bearing contact on metallic bone-plates and screws, such as screw-plate connections, bone-plate interfaces and screw-bone interfaces. Of primary clinical concern is the generation of ionic and particulate debris through fracture and abrasion of the metal oxide protective layers covering implant alloys /1/. This debris produced locally within crevices of component connections can migrate away from junctions and cause injury both systemically and in the local tissue. Clinical concern about the release and distribution of metallic degradation products is justified by the known potential toxicities of the elements used in modern orthopedic implant alloys (titanium, aluminum, vanadium, cobalt, chromium, molybdenum and nickel) and known pathologies associated with metal implant degradation (i.e. hypersensitivity, particle induced inflammation, etc.) /2/. However, little is known of the short and long-term biologic impact of soluble metal-protein complexes formed from the degradation products of implants.
引用
收藏
页码:183 / 213
相关论文
共 50 条
  • [21] Fretting-corrosion at the Implant-Abutment Interface Simulating Clinically Relevant Conditions
    Sun, Yani
    Shukla, Apurwa
    Ramachandran, Remya Ampadi
    Kanniyappan, Hemalatha
    Yang, Bin
    Harlow, Rand
    Campbell, Stephen D.
    Thalji, Ghadeer
    Mathew, Mathew
    DENTAL MATERIALS, 2024, 40 (11) : 1823 - 1831
  • [22] In vitro simulation of fretting-corrosion in hip implant modular junctions: The influence of pH
    Royhman, Dmitry
    Patel, Megha
    Jacobs, Joshua J.
    Wimmer, Markus A.
    Hallab, Nadim J.
    Mathew, Mathew T.
    MEDICAL ENGINEERING & PHYSICS, 2018, 52 : 1 - 9
  • [23] Fretting and Fretting Corrosion Processes of Ti6Al4V Implant Alloy in Simulated Oral Cavity Environment
    Klekotka, Marcin
    Dabrowski, Jan Ryszard
    Recko, Katarzyna
    MATERIALS, 2020, 13 (07)
  • [24] Nanomechanical Behavior, Adhesion and Corrosion Resistance of Hydroxyapatite Coatings for Orthopedic Implant Applications
    Khlifi, Kaouther
    Dhiflaoui, Hafedh
    Ben Rhouma, Amir
    Faure, Joel
    Benhayoune, Hicham
    Ben Cheikh Laarbi, Ahmed
    COATINGS, 2021, 11 (04)
  • [25] A preliminary assessment of the corrosion behavior of CoCrAlSi alloy as a potential orthopedic implant material
    Ozdemir, Huseyin Can
    Blank, Tatiana
    Gerstein, Gregory
    Canadinc, Demircan
    Maier, Hans Juergen
    JOURNAL OF MATERIALS RESEARCH, 2025, : 527 - 537
  • [26] Solutions for fretting corrosion
    van Dijk, P
    van Meijl, F
    IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 1999, 22 (01): : 47 - 52
  • [27] CONTROL OF FRETTING CORROSION
    BUDINSKI, KG
    THIN SOLID FILMS, 1979, 64 (03) : 359 - 363
  • [28] FRETTING AND CORROSION FATIGUE
    不详
    CORROSION SCIENCE, 1970, 10 (05) : 384 - &
  • [29] FRETTING OF MODULAR IMPLANT SYSTEMS
    WILLMANN, G
    BIOMEDIZINISCHE TECHNIK, 1993, 38 (03): : 48 - 52
  • [30] Fretting corrosion tests on orthopedic plates and screws made of ASTM f138 stainless steel
    Instituto Nacional de Tecnologia – INT, Av. Venezuela, 82, Rio de Janeiro
    RJ
    CEP 20.081-312, Brazil
    不详
    SC, Brazil
    Res. Biomed. Eng., 2 (169-175):