USING CORRELATION EQUATIONS TO INCREASE MEASUREMENT ACCURACY.

被引:0
|
作者
Lotonov, M.A.
Bednyakov, S.S.
Kolomytsev, V.M.
机构
关键词
ELECTRIC MEASUREMENTS - Voltage - RESISTORS - VOLTMETERS;
D O I
暂无
中图分类号
学科分类号
摘要
The authors derive a formula for the additive systematic-error component for a voltmeter on the basis that the random component is eliminated by processing repeated measurements. We use the law that the voltages 'U prime and U double prime are equal in two parallel arms composed correspondingly of n and m series-connected resistors of the same nominal value. The device for determining the additive component was implemented as an external one, although a preliminary analysis shows that in principle it is possible to build the proposed device into a digital means of measurement containing a microprocessor and to automate the determination of this error component. An approximate calculation shows that the time required for that measurement would not exceed the self-monitoring time based on built-in measures, while the memory volume required is actually less (2-4 k). Such memory can be implemented with a 565RU21 LSI interfaced to a K580IK80 LSI central processor.
引用
收藏
页码:617 / 621
相关论文
共 50 条
  • [31] INCREASE IN ACCURACY OF PRECIPITATION MEASUREMENT BY RADAR
    KOSTAREV, VV
    CERNIKOV, AA
    ZEITSCHRIFT FUR METEOROLOGIE, 1971, 22 (1-5): : 73 - &
  • [32] FABRICATING CENTERS CUT WITH NC ACCURACY.
    MAYER, CHARLES A.
    1982, V 55 (N 7): : 68 - 70
  • [33] INERTIAL SURVEYING: PRINCIPLES, METHODS AND ACCURACY.
    Cross, P.A.
    1600, (06):
  • [34] SIMPLE MATHEMATICS APPLIED TO INVENTORY ACCURACY.
    Neeley, Parley S.
    Production and inventory management Washington, D.C., 1987, 28 (03): : 64 - 68
  • [35] ZEROS OF POLYNOMIAL AND AN ESTIMATION OF ITS ACCURACY.
    IGARASHI, MASAO
    1982, V 5 (N 3): : 172 - 175
  • [36] EFFECT OF SOME VARIABLES ON ECM ACCURACY.
    Bhatia, S.M.
    Dave, R.K.
    Choubey, M.
    Journal of the Institution of Engineers (India): Mechanical Engineering Division, 1977, 58 (pt ME 2-3): : 84 - 87
  • [37] Use of multi-functional sensing for the measurement of electrolytic concentration in solution with higher accuracy.
    Ismail, AM
    Khan, SR
    Shida, K
    ISIE 2001: IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS PROCEEDINGS, VOLS I-III, 2001, : 2033 - 2037
  • [38] Using Transitivity to Increase the Accuracy of Sample-Based Pearson Correlation Coefficients
    Phillips, Taylor
    GauthierDickey, Chris
    Thurimella, Ramki
    DATA WAREHOUSING AND KNOWLEDGE DISCOVERY, 2010, 6263 : 157 - 171
  • [39] MEASURING A BROADBAND RANGE WITH SPEED AND ACCURACY.
    Sakai, Norihisa
    JEE. Journal of electronic engineering, 1988, 25 (253): : 52 - 53
  • [40] Discharge Measurements: Gaging Station Accuracy.
    Masson, J.M.
    Ghio, M.
    Lallement, Ch.
    Parsy, C.
    Philippe, J.P.
    Houille Blanche, 1987, 42 (4-5): : 333 - 338