All-fiber white-light velocity interferometric system of any reflector

被引:0
|
作者
Hu, Li [1 ]
Jia, Bo [1 ]
Ye, Kunzheng [1 ]
Tan, Hua [1 ]
Zhou, Xianming [1 ]
Li, Xuemei [1 ]
Hu, Changmin [1 ]
机构
[1] Univ of Electronic Science and, Technology, Chengdu, China
来源
Guangxue Xuebao/Acta Optica Sinica | 2000年 / 20卷 / 06期
关键词
Doppler effect - Light reflection - Optical fibers;
D O I
暂无
中图分类号
学科分类号
摘要
A new velocity interferometric system called all-fiber white-light velocity interferometric system of any reflector (FVISAR) was demonstrated. The important development of the FVISAR were discussed, such as the perfect space-interference property and the potential to work with very short coherence length light source even if white-light, in comparison with the conventional velocity interferometric system of any reflector (VISAR) which consists of complicated discrete optical elements. The key points in designing a FVISAR were described, and an experimental FVISAR system with very low source power was reported. Preliminary tests to the FVISAR were conducted using the Hopkinson Bar system. The results show that the observed free-surface velocities of LY12 aluminum samples are in good agreement with theoretical values by impedance match.
引用
收藏
页码:814 / 820
相关论文
共 50 条
  • [41] A Novel All-fiber Velocity Measurement System With High Fringe Contrast
    Lin, Peng
    Jia, Bo
    Hong, Guangwei
    INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2013: FIBER OPTIC SENSORS AND OPTICAL COHERENCE TOMOGRAPHY, 2013, 8914
  • [42] Sapphire-fiber-based white-light interferometric sensor for high-temperature measurements
    Zhu, YZ
    Huang, ZY
    Shen, FB
    Wang, AB
    OPTICS LETTERS, 2005, 30 (07) : 711 - 713
  • [43] CHARACTERISTICS OF SYNTHESIZED LIGHT-SOURCES FOR WHITE-LIGHT INTERFEROMETRIC SYSTEMS
    WANG, DN
    NING, YN
    GRATTAN, KTV
    PALMER, AW
    WEIR, K
    OPTICS LETTERS, 1993, 18 (22) : 1884 - 1886
  • [44] A curve fitting signal processing scheme for a white-light interferometric system with a synthetic source
    Wang, Q
    Ning, YN
    Grattan, KTV
    Palmer, AW
    OPTICS AND LASER TECHNOLOGY, 1997, 29 (07): : 371 - 376
  • [45] All-fiber interferometric sensors for simultaneous measurement of dual parameters
    Cao, Ye
    Zhao, Chen
    Tong, Zheng-Rong
    Guangzi Xuebao/Acta Photonica Sinica, 2015, 44 (10):
  • [46] White-light interferometric measurements of aqueous media dispersive properties
    Stolarski, DJ
    Thomas, RJ
    Noojin, GD
    Payne, DJ
    Rockwell, BA
    LASER-TISSUE INTERACTION VIII, PROCEEDINGS OF, 1997, 2975 : 155 - 162
  • [47] A white-light system for inspecting and measuring endface topography of fiber connector
    Zou, WD
    Du, N
    Xiao, HR
    Fu, YJ
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 983 - 986
  • [48] ANALYSIS OF DISPERSION EFFECTS FOR WHITE-LIGHT INTERFEROMETRIC FIBEROPTIC SENSORS
    URBANCZYK, W
    BOCK, WJ
    APPLIED OPTICS, 1994, 33 (01): : 124 - 129
  • [49] A white-light profiling algorithm adopting the multiwavelength interferometric technique
    Hsu, HC
    Tung, CH
    Kao, CF
    Chang, CC
    INTERFEROMETRY XII: TECHNIQUES AND ANALYSIS, 2004, 5531 : 244 - 249
  • [50] Single-shot white-light dispersive interferometric profilometer
    Zhu, Pei
    Wang, Kaiwei
    Zhao, Shuangshuang
    OPTICAL DESIGN AND TESTING IV, 2010, 7849