Erosion of Magnetic Stator Circuits of Turbogenerators during Earth Faults.

被引:0
|
作者
Zielichowski, Mieczyslaw
机构
关键词
MAGNETIC CIRCUITS - Erosion;
D O I
暂无
中图分类号
学科分类号
摘要
An explanation is given of recent research concerning the erosion of stator laminations of turboalternators. Consideration is given to the following factors which up to now have been neglected: thermal pitting of insulation, stacking pressure, temperature of stator laminations and transients in a 3-phase system. Tests were also conducted to obtain information concerning the erosion in magnetic circuits.
引用
收藏
页码:226 / 233
相关论文
共 50 条
  • [31] EQUIVALENT CIRCUITS OF SYNCHRONOUS MACHINES FOR CALCULATING QUANTITIES OF ROTOR DURING TRANSIENT PROCESSES AND ASYNCHRONOUS STARTING .I. TURBOGENERATORS
    CANAY, M
    BROWN BOVERI REVIEW, 1969, 56 (02): : 60 - &
  • [32] CALCULATION OF MAGNETIC FIELD OF ROTATING MACHINES .5. FIELD IN END REGION OF TURBOGENERATORS AND EDDY-CURRENT LOSS IN END PLATES OF STATOR CORES
    STOLL, RL
    HAMMOND, P
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1966, 113 (11): : 1793 - &
  • [33] Multispacecraft observation of magnetic cloud erosion by magnetic reconnection during propagation
    Ruffenach, A.
    Lavraud, B.
    Owens, M. J.
    Sauvaud, J. -A.
    Savani, N. P.
    Rouillard, A. P.
    Demoulin, P.
    Foullon, C.
    Opitz, A.
    Fedorov, A.
    Jacquey, C. J.
    Genot, V.
    Louarn, P.
    Luhmann, J. G.
    Russell, C. T.
    Farrugia, C. J.
    Galvin, A. B.
    JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 2012, 117
  • [34] Time- Frequency Domain Based Diagnostics of Stator Faults in Motors Drives via Dispersal Magnetic Field
    Eldeeb, Hassan H.
    Zhao, Haisen
    Mohammed, Osama A.
    2020 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2020, : 4903 - 4907
  • [35] Global finite element model to study power transformers behaviour during and after inner electrical faults. Application to explosion and fire protection.
    Darcherif, AM
    Prigent, S
    Dedulle, JM
    Magnier, P
    Scheurer, D
    Eurocon 2005: The International Conference on Computer as a Tool, Vol 1 and 2 , Proceedings, 2005, : 1430 - 1433
  • [36] Interturn Stator Faults Analysis of a 200-MVA Hydrogenerator During Transient Operation Using FEM
    Dallas, Stefanos E.
    Safacas, Athanasios N.
    Kappatou, Joya C.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (04) : 1151 - 1160
  • [37] Detection of the Short-Circuit Faults in the Stator Winding of Induction Motors based on Harmonics of the Neighboring Magnetic Field
    Fireteanu, V.
    SENSORS & THEIR APPLICATIONS XVII, 2013, 450
  • [38] Reduction of Unbalanced Magnetic Pull (UMP) due to Equipotential Connections among Parallel Circuits of the Stator Winding
    Oliveira, Wilian
    Uemori, Mauro
    Rocha, Johnny
    Carlson, Renato
    2009 IEEE INTERNATIONAL ELECTRIC MACHINES & DRIVES CONFERENCE, VOLS 1-3, 2009, : 765 - +
  • [39] Magnetic field intensity under the power lines during the faults
    Ladniak, Leslaw
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (05): : 190 - 195
  • [40] Magnetic Saturation Effects in a Synchronous Generator During Unbalanced Faults
    Louie, Kwok-Wai K. W.
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2006, 6 (02): : 1 - 19