Characteristics of using a jet-pump for a boron injection system in nuclear heating reactors

被引:0
|
作者
Tsinghua Univ, Beijing, China [1 ]
机构
来源
Qinghua Daxue Xuebao | / 12卷 / 57-60期
关键词
Boron - Jet pumps - Reactor shutdowns;
D O I
暂无
中图分类号
学科分类号
摘要
It is a new kind of safety measurement to inject boron liquid into the nuclear reactor during crisis situation. In order to prevent a large amount of coolant from discharging from core a jet-pump was used as safety device of the boron injection system in 5 MW heating reactor. Whether the jet-pump could be used as a safety device of the boron injection system was studied experimentally. The experimental study was performed under the following conditions: pressure 0.1-1.5MPa, temperature 20-198°C, diameter of the work nozzle of the jet pump 1-8 mm, and the charging flow rate 0.1-0.8kg/s. The experiment result shows that the jet pump suitably designed can satisfy the design requirement as a safety device in the boron injection system of the nuclear reactor. The jet pump has been used in the 5MW heating reactor.
引用
收藏
相关论文
共 50 条
  • [31] Effects of the duct on the vibro-acoustic characteristics of the pump-jet-shaft-submarine system under pump-jet excitation
    Su, Zhiwei
    Shi, Shuaikang
    Huang, Xiuchang
    Rao, Zhiqiang
    Hua, Hongxing
    OCEAN ENGINEERING, 2022, 254
  • [32] Research on Pipe Network Transformation of Central Heating System Based on Adjustable Jet Pump Technology
    Han, Jingtong
    Li, Deying
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 751 - 756
  • [33] Load characteristics analysis of the water source heat pump heating system using data center waste heat
    Zhou, Feng
    Song, Yu
    Ma, Guoyuan
    ENERGY CONVERSION AND MANAGEMENT, 2023, 296
  • [34] Field testing and applications of Wellcom system using jet pump technology
    Sarshar, MM
    Loh, WL
    Beg, NA
    Villa, M
    Paone, F
    8TH INTERNATIONAL CONFERENCE ON MULTIPHASE '97 - HOW DEEP? HOW FAR? HOW SOON?, 1997, (24): : 293 - 318
  • [35] Investigation of the characteristics of an oil jet pump when using a group ground drive
    Denis, Panevnyk
    Radoslav, Krehel
    JOURNAL OF ENGINEERING RESEARCH, 2023, 11 (01):
  • [36] Effects of intermediate pressure on the heating performance of a heat pump system using R410A vapor-injection technique
    Roh, Chul Woo
    Kim, Min Soo
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (08): : 1911 - 1921
  • [37] Measurement of the depletion of neutraliser target due to gas heating in the JET neutral beam injection system
    Surrey, E
    Challis, CD
    Ciric, D
    Cox, SJ
    Crowley, B
    Jenkins, I
    Jones, TTC
    Keeling, D
    FUSION ENGINEERING AND DESIGN, 2005, 73 (2-4) : 141 - 153
  • [38] Heating performance of a VRF heat pump system incorporating double vapor injection in scroll compressor
    Kang, Donghoon
    Jeong, Ji Hwan
    Ryu, Byoungjin
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 96 : 50 - 62
  • [39] Spray characteristics of the rotating fuel injection system of a micro-jet engine
    Seong Man Choi
    Seong Ho Jang
    Dong Hun Lee
    Gyong Won You
    Journal of Mechanical Science and Technology, 2010, 24 : 551 - 558
  • [40] Spray characteristics of the rotating fuel injection system of a micro-jet engine
    Choi, Seong Man
    Jang, Seong Ho
    Lee, Dong Hun
    You, Gyong Won
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2010, 24 (02) : 551 - 558