Wear of a mobile bearing uni-compartmental knee replacement prosthesis: A comparison of in vitro and in vivo wear rates

被引:0
|
作者
Ellison P.J. [1 ]
Traynor A. [1 ]
Casey B.P. [1 ]
Collins S.N. [1 ]
机构
[1] Corin, Ltd., Corinium Centre, Cirencester, Gloucestershire
来源
Journal of ASTM International | 2011年 / 8卷 / 02期
关键词
Arthroplasty; Knee; Replacement; Uni-compartmental; Wear;
D O I
10.1520/JAI103328
中图分类号
学科分类号
摘要
Wear induced osteolysis is cited as the primary cause of aseptic loosening in knee replacements. It has been postulated that mobile bearing (MB) knee prostheses reduce wear as they allow lower contact stress through high congruency between components while maintaining a wide range of joint motion. In vitro wear simulations are preclinical tests for predicting the performance of new designs of partial and total knee replacements. This study investigates the wear of a leading design of MB unicompartmental knee replacement (UKR) by quantifying the in vitro wear rate and linear penetration of the polyethylene meniscal bearing. Three medial and three lateral MB UKRs (Uniglide, Corin, Ltd., U.K.) were tested in a three station wear simulator using force control as defined in ISO 14243-1. Volumetric wear was determined gravimetrically every half million cycles (MC) up to 10 MC. Maximum linear penetration wear was measured after 10 MC. Volumetric wear rates of 1.65±0.28 mm 3/MC (mean(SD) and 1.66±0.31 mm3/MC were recorded for the medial and lateral bearings, respectively, and the wear of all bearings was linear. Previous simulator studies have reported mean wear rates of 3.8 ± 10.4 mm3/MC for MB UKRs. Maximum linear penetration wear rates of 0.013(0.001 mm/MC and 0.012± 0.001 mm/MC were recorded for the medial and lateral bearings, respectively, after 10 MC. This was in agreement with that reported for well functioning MB UKRs through in vivo measurement (0.01 mm/year) and compared favourably to that reported for fixed bearing designs (0.15 mm/year). The results of this study show that in vitro measurements correlate well to in vivo measurements of wear. This indicates that the current in vitro methodology for the simulation of wear in MB UKRs is a valid tool for preclinical assessment of MB UKR prostheses. Copyright © 2011 by ASTM International.
引用
收藏
相关论文
共 50 条
  • [41] Comparison of in vivo polyethylene wear particles between mobile- and fixed-bearing TKA in the same patients
    Yukihide Minoda
    Kanako Hata
    Mitsuhiko Ikebuchi
    Shigekazu Mizokawa
    Yoichi Ohta
    Hiroaki Nakamura
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 2887 - 2893
  • [42] Comparison of a new mobile-bearing total knee prosthesis with a fixed-bearing prosthesis:: a matched pair analysis
    Geiger, Florian
    Mau, Hans
    Krueger, Marlis
    Thomsen, Marc
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (03) : 285 - 291
  • [43] Comparison of a new mobile-bearing total knee prosthesis with a fixed-bearing prosthesis: a matched pair analysis
    Florian Geiger
    Hans Mau
    Marlis Krüger
    Marc Thomsen
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 285 - 291
  • [44] Evidence that in vivo wear damage alters kinematics and contact stresses in a total knee replacement
    Williams J.L.
    Knox D.A.
    Teeter M.G.
    Holdsworth D.W.
    Mihalko W.M.
    Journal of Long-Term Effects of Medical Implants, 2010, 20 (01) : 43 - 48
  • [45] Quantification of Wear Rates and Plastic Deformation on Mobile Unicompartmental UHMWPE Tibial Knee Inserts
    Affatato, Saverio
    Modena, Enrico
    Carmignato, Simone
    Grupp, Thomas M.
    Taddei, Paola
    TRIBOLOGY LETTERS, 2013, 52 (01) : 57 - 65
  • [46] Quantification of Wear Rates and Plastic Deformation on Mobile Unicompartmental UHMWPE Tibial Knee Inserts
    Saverio Affatato
    Enrico Modena
    Simone Carmignato
    Thomas M. Grupp
    Paola Taddei
    Tribology Letters, 2013, 52 : 57 - 65
  • [47] Comparison of in-vitro and clinical wear rates of composite resins.
    Barkmeier, WW
    Latta, MA
    Christensen, TL
    Erickson, RL
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 246 - 246
  • [48] Instability after total knee replacement with a mobile-bearing prosthesis in a patient with multiple sclerosis
    Rao, V
    Targett, JPG
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (05): : 731 - 732
  • [49] In-vitro wear and radiographic analyses of high flexion posterior stabilized mobile- and fixed-bearing knee implants
    Popoola, Oludele
    Yu, Ning
    Scuderi, Giles
    Journal of ASTM International, 2012, 9 (01):
  • [50] A New Method of In Vitro Wear Assessment of the UHMWPE Tibial Insert in Total Knee Replacement
    Affatato, Saverio
    Cristofolini, Luca
    Leardini, Walter
    Erani, Paolo
    Zavalloni, Mara
    Tigani, Domenico
    Viceconti, Marco
    ARTIFICIAL ORGANS, 2008, 32 (12) : 942 - 948