Wear of a mobile bearing uni-compartmental knee replacement prosthesis: A comparison of in vitro and in vivo wear rates

被引:0
|
作者
Ellison P.J. [1 ]
Traynor A. [1 ]
Casey B.P. [1 ]
Collins S.N. [1 ]
机构
[1] Corin, Ltd., Corinium Centre, Cirencester, Gloucestershire
来源
Journal of ASTM International | 2011年 / 8卷 / 02期
关键词
Arthroplasty; Knee; Replacement; Uni-compartmental; Wear;
D O I
10.1520/JAI103328
中图分类号
学科分类号
摘要
Wear induced osteolysis is cited as the primary cause of aseptic loosening in knee replacements. It has been postulated that mobile bearing (MB) knee prostheses reduce wear as they allow lower contact stress through high congruency between components while maintaining a wide range of joint motion. In vitro wear simulations are preclinical tests for predicting the performance of new designs of partial and total knee replacements. This study investigates the wear of a leading design of MB unicompartmental knee replacement (UKR) by quantifying the in vitro wear rate and linear penetration of the polyethylene meniscal bearing. Three medial and three lateral MB UKRs (Uniglide, Corin, Ltd., U.K.) were tested in a three station wear simulator using force control as defined in ISO 14243-1. Volumetric wear was determined gravimetrically every half million cycles (MC) up to 10 MC. Maximum linear penetration wear was measured after 10 MC. Volumetric wear rates of 1.65±0.28 mm 3/MC (mean(SD) and 1.66±0.31 mm3/MC were recorded for the medial and lateral bearings, respectively, and the wear of all bearings was linear. Previous simulator studies have reported mean wear rates of 3.8 ± 10.4 mm3/MC for MB UKRs. Maximum linear penetration wear rates of 0.013(0.001 mm/MC and 0.012± 0.001 mm/MC were recorded for the medial and lateral bearings, respectively, after 10 MC. This was in agreement with that reported for well functioning MB UKRs through in vivo measurement (0.01 mm/year) and compared favourably to that reported for fixed bearing designs (0.15 mm/year). The results of this study show that in vitro measurements correlate well to in vivo measurements of wear. This indicates that the current in vitro methodology for the simulation of wear in MB UKRs is a valid tool for preclinical assessment of MB UKR prostheses. Copyright © 2011 by ASTM International.
引用
收藏
相关论文
共 50 条
  • [31] Mobile-bearing total knee arthroplasty - Design factors in minimizing wear
    Dennis, Douglas A.
    Komistek, Richard A.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) : 70 - 77
  • [32] Comparison of wear in a total knee replacement under different kinematic conditions
    Barnett, PI
    Fisher, J
    Auger, DD
    Stone, MH
    Ingham, E
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2001, 12 (10-12) : 1039 - 1042
  • [33] Comparison of wear in a total knee replacement under different kinematic conditions
    Petra I. Barnett
    John Fisher
    Daniel D. Auger
    Martin H. Stone
    Eileen Ingham
    Journal of Materials Science: Materials in Medicine, 2001, 12 : 1039 - 1042
  • [34] Polyethylene wear particle generation in vivo in an alumina medial pivot total knee prosthesis
    Minoda, Y
    Kobayashi, A
    Iwaki, H
    Miyaguchi, M
    Kadoya, Y
    Ohashi, H
    Takaoka, K
    BIOMATERIALS, 2005, 26 (30) : 6034 - 6040
  • [35] Comparison of in Vivo Characteristics of Polyethylene Wear Particles Produced by a Metal and a Ceramic Femoral Component in Total Knee Replacement
    Veigl, D.
    Vavrik, P.
    Pokorny, D.
    Slouf, M.
    Pavlova, E.
    Landor, I.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2011, 78 (01) : 49 - 55
  • [36] Influence of design and bearing material on polyethylene wear particle generation in total knee replacement
    Utzschneider, S.
    Paulus, A.
    Datz, J. -C.
    Schroeder, C.
    Sievers, B.
    Wegener, B.
    Jansson, V.
    ACTA BIOMATERIALIA, 2009, 5 (07) : 2495 - 2502
  • [37] A hybrid apparatus for friction and accelerated wear testing of total knee replacement bearing materials
    Chyr, Anthony
    Sanders, Anthony P.
    Raeymaekers, Bart
    WEAR, 2013, 308 (1-2) : 54 - 60
  • [38] In vitro wear simulation on the RandomPOD wear testing system as a screening method for bearing materials intended for total knee arthroplasty
    Saikko, Vesa
    JOURNAL OF BIOMECHANICS, 2014, 47 (11) : 2774 - 2778
  • [39] Particle size and morphology of UHMWPE wear debris in failed total knee arthroplasties - a comparison between mobile bearing and fixed bearing knees
    Huang, CH
    Ho, FY
    Ma, HM
    Yang, CT
    Liau, JJ
    Kao, HC
    Young, TH
    Cheng, CK
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (05) : 1038 - 1041
  • [40] Comparison of in vivo polyethylene wear particles between mobile- and fixed-bearing TKA in the same patients
    Minoda, Yukihide
    Hata, Kanako
    Ikebuchi, Mitsuhiko
    Mizokawa, Shigekazu
    Ohta, Yoichi
    Nakamura, Hiroaki
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (09) : 2887 - 2893