Wear of a mobile bearing uni-compartmental knee replacement prosthesis: A comparison of in vitro and in vivo wear rates

被引:0
|
作者
Ellison P.J. [1 ]
Traynor A. [1 ]
Casey B.P. [1 ]
Collins S.N. [1 ]
机构
[1] Corin, Ltd., Corinium Centre, Cirencester, Gloucestershire
来源
Journal of ASTM International | 2011年 / 8卷 / 02期
关键词
Arthroplasty; Knee; Replacement; Uni-compartmental; Wear;
D O I
10.1520/JAI103328
中图分类号
学科分类号
摘要
Wear induced osteolysis is cited as the primary cause of aseptic loosening in knee replacements. It has been postulated that mobile bearing (MB) knee prostheses reduce wear as they allow lower contact stress through high congruency between components while maintaining a wide range of joint motion. In vitro wear simulations are preclinical tests for predicting the performance of new designs of partial and total knee replacements. This study investigates the wear of a leading design of MB unicompartmental knee replacement (UKR) by quantifying the in vitro wear rate and linear penetration of the polyethylene meniscal bearing. Three medial and three lateral MB UKRs (Uniglide, Corin, Ltd., U.K.) were tested in a three station wear simulator using force control as defined in ISO 14243-1. Volumetric wear was determined gravimetrically every half million cycles (MC) up to 10 MC. Maximum linear penetration wear was measured after 10 MC. Volumetric wear rates of 1.65±0.28 mm 3/MC (mean(SD) and 1.66±0.31 mm3/MC were recorded for the medial and lateral bearings, respectively, and the wear of all bearings was linear. Previous simulator studies have reported mean wear rates of 3.8 ± 10.4 mm3/MC for MB UKRs. Maximum linear penetration wear rates of 0.013(0.001 mm/MC and 0.012± 0.001 mm/MC were recorded for the medial and lateral bearings, respectively, after 10 MC. This was in agreement with that reported for well functioning MB UKRs through in vivo measurement (0.01 mm/year) and compared favourably to that reported for fixed bearing designs (0.15 mm/year). The results of this study show that in vitro measurements correlate well to in vivo measurements of wear. This indicates that the current in vitro methodology for the simulation of wear in MB UKRs is a valid tool for preclinical assessment of MB UKR prostheses. Copyright © 2011 by ASTM International.
引用
收藏
相关论文
共 50 条
  • [1] Comparison of day-case versus inpatient uni-compartmental knee replacement
    Gao, Neng-Ping
    Al-Dadah, Oday
    MUSCULOSKELETAL CARE, 2023, 21 (01) : 16 - 24
  • [2] Lateral uni-compartmental knee replacement: current concepts and future directions
    Servien, E.
    Merini, A.
    Lustig, S.
    Neyret, P.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (11) : 2501 - 2508
  • [3] Robotic Arm Assisted Uni-Compartmental Knee Replacement The Learning Curve
    O'Neill, C. J.
    Brennan, S.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2017, 186 : S331 - S331
  • [4] Ultrasound Examination for Cement Extrusion After Uni-Compartmental Knee Replacement
    Siu, Peter Kam-To
    Wu, Wei-Ting
    Ozcakar, Levent
    Chang, Ke-Vin
    DIAGNOSTICS, 2025, 15 (01)
  • [5] Lateral uni-compartmental knee replacement: current concepts and future directions
    E. Servien
    A. Merini
    S. Lustig
    P. Neyret
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 2501 - 2508
  • [6] Comparison of articular and backside polyethylene wear in mobile bearing unicompartmental knee replacement
    Teeter, Matthew G.
    Howard, James L.
    McCalden, Richard W.
    Naudie, Douglas D.
    KNEE, 2017, 24 (02): : 429 - 433
  • [7] In vitro wear assessments of fixed and mobile UHMWPE total knee replacement
    Affatato, Saverio
    Bracco, Pierangiola
    Sudanese, Alessandra
    MATERIALS & DESIGN, 2013, 48 : 44 - 51
  • [8] Polyethylene wear of mobile-bearing unicompartmental knee replacement at 20 years
    Kendrick, B. J. L.
    Simpson, D. J.
    Kaptein, B. L.
    Valstar, E. R.
    Gill, H. S.
    Murray, D. W.
    Price, A. J.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (04): : 470 - 475
  • [9] Comparison of wear of mobile and fixed bearing knees tested in a knee simulator
    Johnson, TS
    Laurent, MP
    Yao, JQ
    Blanchard, CR
    WEAR, 2003, 255 (7-12) : 1107 - 1112
  • [10] Biomechanical Effect of Various Tibial Bearing Materials in Uni-Compartmental Knee Arthroplasty Using Finite Element Analysis
    Kwak, Yoon Hae
    Hong, Hyoung-Taek
    Koh, Yong-Gon
    Kang, Kyoung-Tak
    APPLIED SCIENCES-BASEL, 2020, 10 (18):