Scanning Hartmann test method and its application lens aberration measurement

被引:0
|
作者
Liu, Dan [1 ,2 ]
Huang, Huijie [1 ]
Ren, Bingqiang [1 ]
Zeng, Aijun [1 ]
Yan, Yan [1 ]
Wang, Xiangzhao [1 ]
机构
[1] Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
[2] Graduate School, Chinese Academy of Sciences, Beijing 100039, China
关键词
Aberrations - Lenses - Light measurement - Scanning;
D O I
暂无
中图分类号
学科分类号
摘要
A scanning Hartmann test method is proposed and its measurement principle is described. The scanning Hartmann test setup is formed by modifying the Hartmann screen of the conventional Hartmann test setup. With the rotation of the scanning Hartmann screen and the improved hole arrangement, the whole information of the lens to be tested in the full aperture can be obtained. The measurement accuracy of the aberration is improved and the local error of the lens can be got. In the method, no change of the Hartmann screen is needed for measuring the lenses of different aperture sizes. Experimental results of aberration measurements of two lenses are given to verify the usefulness of the setup.
引用
收藏
页码:725 / 728
相关论文
共 50 条
  • [1] Scanning Hartmann test method and its application to lens aberration measurement
    刘丹
    黄惠杰
    任冰强
    曾爱军
    闫岩
    王向朝
    ChineseOpticsLetters, 2006, (12) : 725 - 728
  • [2] Encircled energy measurement for focusing lens based on scanning Hartmann test
    Liu, Dan
    Huang, Huijie
    Ren, Bingqiang
    Zeng, Aijun
    Huang, Lihua
    Wang, Xiangzhao
    OPTIK, 2007, 118 (08): : 357 - 360
  • [3] Measurement of Longitudinal Chromatic Aberration in the Last Crystalline Lens Surface Using Hartmann Test and Purkinje Images
    Calderon-Uribe, Uriel
    Hernandez-Gomez, Geovanni
    Gomez-Vieyra, Armando
    SENSORS, 2022, 22 (07)
  • [4] Aberration measurement for progressive addition lens based on Hartmann-Shack Sensor
    Zhu, Lan
    Chen, Jiabi
    Xu, Jianghua
    Pan, Huimin
    Zhang, Haowei
    Zhuang, Sonlin
    SIXTH INTERNATIONAL SYMPOSIUM ON PRECISION MECHANICAL MEASUREMENTS, 2013, 8916
  • [6] Application of the Aberration Ring Test (ARTEMISTM) to determine lens quality and predict its lithographic performance
    Moers, M
    van der Laan, H
    Zellenrath, M
    de Boeij, W
    Beaudry, N
    Cummings, KD
    van Zwol, A
    Becht, A
    Willekers, R
    OPTICAL MICROLITHOGRAPHY XIV, PTS 1 AND 2, 2001, 4346 : 1379 - 1387
  • [7] Classical Hartmann test with scanning
    Diaz-Uribe, Rufino
    Granados-Agustin, Fermin
    Cornejo-Rodriguez, Alejandro
    OPTICS EXPRESS, 2009, 17 (16): : 13959 - 13973
  • [8] Measurement of lens aberration by using in-situ interferometer and classification of lens for correct application
    Seong, N
    Yeo, G
    Cho, H
    Moon, J
    OPTICAL MICROLITHOGRAPHY XIII, PTS 1 AND 2, 2000, 4000 : 30 - 39
  • [9] Aberration extraction in the Hartmann test by use of spatial filters
    Robledo-Sánchez, C
    Camacho-Basilio, G
    Jaramillo-Núñez, A
    Gale, D
    APPLIED OPTICS, 1999, 38 (16) : 3483 - 3489
  • [10] Aberration extraction in the Hartmann test by use of spatial filters
    Robledo-Sánchez, Carlos
    Camacho-Basilio, Gilberto
    Jaramillo-Núñez, Alberto
    Gale, David
    Applied Optics, 1999, 38 (16): : 3483 - 3489